background image

 

EKHWS150~30 E300BA3Z2

 

Domestic hot water tank for air to water heat pump system

 

4P610547-1 – 2020.01

 

Installation manual

 

1

 

C

 

ONTENTS

 

Page

 

Introduction........................................................................................ 1

 

General information ................................................................................... 1
Scope of this manual ................................................................................. 1
Model identification .................................................................................... 1

 

Accessories ....................................................................................... 1

 

Accessories supplied with the domestic hot water tank............................. 1

Installation of the EKHWS domestic hot water tank .......................................... 2

Main components....................................................................................... 2
Outlook diagram......................................................................................... 3
Installation guidelines................................................................................. 3
Installing the domestic hot water tank........................................................ 3
Connecting the water circuits ..................................................................... 3
Field wiring................................................................................................. 5

 

Maintenance ...................................................................................... 6

Troubleshooting ................................................................................. 7

 

General guidelines ..................................................................................... 7
General symptoms..................................................................................... 7

 

Technical specifications ..................................................................... 7

 

Domestic hot water tank specifications ...................................................... 7

 

I

 

NTRODUCTION

 

General information

 

Thank you for purchasing this domestic hot water tank.

The EKHWS domestic hot water tank with integrated 3 kW electrical
booster heater can be connected to the indoor unit. The domestic hot
water tank is available in three sizes: 150, 200 and 300 litre. All
models are floor mounted. The 200 and 300 litre models are also
available as 400 V versions.

 

Scope of this manual

 

This installation manual describes the procedures for unpacking,
installing and connecting the EKHWS domestic hot water tanks.

 

Model identification

 

A

 

CCESSORIES

 

Accessories supplied with the domestic hot water tank

 

See 

figure 1

 

EKHWS150BA3V3
EKHWS200BA3V3

EKHWS200BA3Z2

EKHWS300BA3V3

EKHWS300BA3Z2

 

Domestic hot water tank 

for air to water heat pump system

 

Installation manual

 

READ THESE INSTRUCTIONS CAREFULLY BEFORE
INSTALLATION. KEEP THIS MANUAL IN A HANDY
PLACE FOR FUTURE REFERENCE.

IMPROPER INSTALLATION OR ATTACHMENT OF
EQUIPMENT OR ACCESSORIES COULD RESULT IN
ELECTRIC SHOCK, SHORT-CIRCUIT, LEAKS, FIRE OR
OTHER DAMAGE TO THE EQUIPMENT. BE SURE ONLY
TO USE ACCESSORIES MADE BY DAIKIN WHICH ARE
SPECIFICALLY DESIGNED FOR USE WITH THE
EQUIPMENT AND HAVE THEM INSTALLED BY A
PROFESSIONAL.

IF UNSURE OF INSTALLATION PROCEDURES OR USE,
ALWAYS CONTACT YOUR DAIKIN DEALER FOR ADVICE
AND INFORMATION.

THE UNIT DESCRIBED IN THIS MANUAL IS DESIGNED
FOR INDOOR INSTALLATION ONLY AND FOR AMBIENT
TEMPERATURES RANGING 0°C~35°C.

 

NOTE

 

Especially for the United Kingdom

 

For installation of an EKHWSU domestic hot water
tank, refer to the installation manual supplied with the
tank.

 

EK

HWS

150

BA

3

V3

 

Booster heater voltage
V3 = 1P, 230 V
Z2 = 2P, 400 V (only for 
200 l and 300 l models)

Capacity booster heater: 3 kW

Series

Indication of storage capacity in litres

Hot Water tank Stainless steel

European Kit

 

1

 

Ther connection wire (12 m)

 

2

 

Contactor - fuse assembly

 

3

 

Contactor fixing screw

 

4

 

Tapping screw

 

5

 

Installation manual

 

6

 

3-way valve + motor

 

NOTE

 

For accessories supplied with the EKHWSU domestic
hot water tank, refer to the manual supplied with the
tank.

 

4PEN610457-1.book  Page 1  Tuesday, February 25, 2020  4:15 PM

Summary of Contents for EKHWS-BA3Z2

Page 1: ...TALLATION MANUAL EKHWS150BA3V3 EKHWS200BA3V3 EKHWS300BA3V3 EKHWS200BA3Z2 EKHWS300BA3Z2 Domestic hot water tank for air to water heat pump system 4PEN610457 1 book Page 1 Tuesday February 25 2020 4 15...

Page 2: ...2 1 4PEN610457 1 book Page 1 Tuesday February 25 2020 4 15 PM...

Page 3: ...EKHWS150BA3V3 EKHWS200BA3V3 EKHWS200BA3Z2 EKHWS300BA3V3 EKHWS300BA3Z2 Domestic hot water tank for air to water heat pump system Installation manual READ THESE INSTRUCTIONS CAREFULLY BEFORE INSTALLATI...

Page 4: ...t guarantee neither good operation nor reliability of the system For those reasons Daikin cannot give warranty of the system in such case The equipment is not intended for use in a potentially explosi...

Page 5: ...leak water can not cause any damage to the installation space and surroundings Installing the domestic hot water tank 1 Check if all domestic hot water tank accessories see Accessories on page 1 are...

Page 6: ...e sure to firmly fix the power supply cord onto the 3 way valve body with a field supplied cable tie like in illustration below 10 Perform the wiring in the indoor unit in accordance with the followin...

Page 7: ...nd X4M to the earthing screw 7 Connect the booster heater power supply and thermal protection cable field supply to terminal X4M earth 1 2 and X2M 13 14 8 Connect the booster heater power supply cable...

Page 8: ...hard water To do so drain the domestic hot water tank remove the booster heater from the domestic hot water tank and immerse in a bucket or similar with lime removing product for 24 hours A4P K6M F2B...

Page 9: ...ON The main water supply is off Check that all shut off valves of the water circuit are completely open POSSIBLE CAUSES CORRECTIVE ACTION The thermal cut out s has have operated Check and reset button...

Page 10: ...NOTES 4PEN610457 1 book Page 1 Tuesday February 25 2020 4 15 PM...

Page 11: ...NOTES 4PEN610457 1 book Page 2 Tuesday February 25 2020 4 15 PM...

Page 12: ...4P610547 1 2020 01 Copyright Daikin 4PEN610457 1 book Page 1 Tuesday February 25 2020 4 15 PM...

Reviews: