7

 

T

 

ROUBLESHOOTING

 

This section provides useful information for diagnosing and correct-
ing certain troubles which may occur in the unit.

 

General guidelines

 

Before starting the troubleshooting procedure, carry out a thorough
visual inspection of the unit and look for obvious defects such as
loose connections or defective wiring.

Before contacting your local dealer, read this chapter carefully, it will
save you time and money.

When a safety device was activated, stop the unit and find out why
the safety device was activated before resetting it. Under no circum-
stances safety devices may be bridged or changed to a value other
than the factory setting. If the cause of the problem cannot be found,
call your local dealer

 

General symptoms

 

Symptom 1: No water flow from hot taps

Symptom 2: Water from hot taps is cold

Symptom 3: Intermittent water discharge

 

T

 

ECHNICAL

 

 

 

SPECIFICATIONS

 

Domestic hot water tank specifications

 

When carrying out an inspection on the supply panel or on
the switch box of the unit, always make sure that the circuit
breaker of the unit is switched off.

 

P

 

OSSIBLE

 

 

 

CAUSES

C

ORRECTIVE

 

ACTION

The main water supply is off.

Check that all shut off valves of the 
water circuit are completely open.

P

OSSIBLE

 

CAUSES

C

ORRECTIVE

 

ACTION

The thermal cut-out(s) has/have 
operated

• Check and reset button(s).
• Check if thermistor is correctly 

installed in thermistor socket.

The indoor unit (EKHBH/X) is not 
operating.

Check the indoor unit (EKHBH/X) 
operation. Refer to the manual 
delivered with the indoor unit .
If any faults are suspected, contact 
your local dealer.

P

OSSIBLE

 

CAUSES

C

ORRECTIVE

 

ACTION

Thermal control failure (water will be 
hot).

Switch off power to the indoor unit .
When discharge has stopped, check 
the thermal controls and replace if 
faulty.
Contact your local dealer.

The expansion vessel is broken.

Replace the expansion vessel.

EKHWS150BA3V3

EKHWS200BA3V3

EKHWS200BA3Z2

EKHWS300BA3V3

EKHWS300BA3Z2

Volume

150 l

200 l

200 l

300 l

300 l

Internal heat exchanger volume

2  l

3  l

3  l

3  l

3  l

Overall dimensions (Ø x H)

595 x 945 mm

595 x 1195 mm

595 x 1195 mm

595 x 1645 mm

595 x 1645 mm

Booster heater, power supply

230 V 50 Hz 1P

230 V 50 Hz 1P

400 V 50 Hz 2P

230 V 50 Hz 1P

400 V 50 Hz 2P

Booster heater, running current

13 A

13 A

7.5 A

13 A

7.5 A

Booster heater, capacity

3 kW

3 kW

3 kW

3 kW

3 kW

Connections

3/4" FBSP

(a)

3/4" FBSP

(a)

3/4" FBSP

(a)

3/4" FBSP

(a)

3/4" FBSP

(a)

Weight (empty)

41 kg

48 kg

48 kg

61 kg

61 kg

Mounting

Floor

Floor

Floor

Floor

Floor

(a) FBSP = Female British Standard Pipe

4PEN610457-1.book  Page 7  Tuesday, February 25, 2020  4:15 PM

Summary of Contents for EKHWS-BA3Z2

Page 1: ...TALLATION MANUAL EKHWS150BA3V3 EKHWS200BA3V3 EKHWS300BA3V3 EKHWS200BA3Z2 EKHWS300BA3Z2 Domestic hot water tank for air to water heat pump system 4PEN610457 1 book Page 1 Tuesday February 25 2020 4 15...

Page 2: ...2 1 4PEN610457 1 book Page 1 Tuesday February 25 2020 4 15 PM...

Page 3: ...EKHWS150BA3V3 EKHWS200BA3V3 EKHWS200BA3Z2 EKHWS300BA3V3 EKHWS300BA3Z2 Domestic hot water tank for air to water heat pump system Installation manual READ THESE INSTRUCTIONS CAREFULLY BEFORE INSTALLATI...

Page 4: ...t guarantee neither good operation nor reliability of the system For those reasons Daikin cannot give warranty of the system in such case The equipment is not intended for use in a potentially explosi...

Page 5: ...leak water can not cause any damage to the installation space and surroundings Installing the domestic hot water tank 1 Check if all domestic hot water tank accessories see Accessories on page 1 are...

Page 6: ...e sure to firmly fix the power supply cord onto the 3 way valve body with a field supplied cable tie like in illustration below 10 Perform the wiring in the indoor unit in accordance with the followin...

Page 7: ...nd X4M to the earthing screw 7 Connect the booster heater power supply and thermal protection cable field supply to terminal X4M earth 1 2 and X2M 13 14 8 Connect the booster heater power supply cable...

Page 8: ...hard water To do so drain the domestic hot water tank remove the booster heater from the domestic hot water tank and immerse in a bucket or similar with lime removing product for 24 hours A4P K6M F2B...

Page 9: ...ON The main water supply is off Check that all shut off valves of the water circuit are completely open POSSIBLE CAUSES CORRECTIVE ACTION The thermal cut out s has have operated Check and reset button...