EKHWS150~30 E300BA3Z2

 

Domestic hot water tank for air to water heat pump system

 

4P610547-1 – 2020.01

 

Installation manual

 

5

 

Field wiring

Power circuit and cable requirements

 

For cable requirements and specifications, refer to "Field wiring" in
the indoor unit installation manual supplied with the EKHBH/X unit.

 

Thermistor cable

 

The distance between the thermistor cable and power supply cable
must always be at least 5 cm to prevent electromagnetic interference
on the thermistor cable.

 

Procedure for EKHWS*V3 and EKHWS*Z2

 

Connections to be made in the domestic hot water tank
electrical box

1

 

Refer to the wiring diagram sticker in the domestic hot water
tank switch box.

 

2

 

Make sure to ensure strain relief of the cable by correct use of
the PG nipple and PG nut (mounted on the domestic hot water
tank).

 

Connections to be made in the indoor unit switch box

3

 

Mount the prewired contactor (K3M), circuit breaker (F2B) and
terminal blocks (X3M, X4M). The contactor must be fixed with
the 2 supplied contactor screws and the terminal blocks must be
fixed with the 2x 2 supplied tapping screws.

 

4

 

Plug the connector connected to the contactor K3M in the socket
X13A on the PCB.

 

5

 

Plug the thermistor cable connector in the socket X9A on the
PCB.

 

6

 

Connect the prewired earth wires of the terminal block X3M and
X4M to the earthing screw.

 

7

 

Connect the booster heater power supply and thermal protection
cable (field supply) to terminal X4M earth, 1, 2, and X2M 13, 14.

 

8

 

Connect the booster heater power supply cable to the terminal
block X3M.

 

9

 

Fix the cables to the cable tie mountings with cable ties to
ensure strain relief.

 

10

 

Set DIP switch SS2-2 on the PCB to ON.

 

11

 

When routing out cables, make sure that these do not obstruct
mounting of the indoor unit cover.

 

 

A main switch or other means for disconnection,
having a contact separation in all poles, must be
incorporated in the fixed wiring in accordance with
relevant local and national legislation.

 

 

All field wiring and components must be installed by a
licensed electrician and must comply with relevant
European and national regulations.

 

 

The field wiring must be carried out in accordance
with the wiring diagram supplied with the unit and the
instructions given below.

 

 

The domestic hot water tank must be earthed via the
indoor unit.

 

 

Be sure to use a dedicated power circuit. Never use a
power circuit shared by another appliance.

 

 

Use one and same dedicated power supply for the
outdoor unit, indoor unit, backup heater and domestic
hot water tank.

 

NOTE

 

Select the power cable in accordance with relevant
local and national regulations.

 

Make sure all field wiring is insulated from the tank body
and heater element or can resist temperatures to 90°C.

 

Switch off the power supply before making any
connections.

 

4PEN610457-1.book  Page 5  Tuesday, February 25, 2020  4:15 PM

Summary of Contents for EKHWS-BA3Z2

Page 1: ...TALLATION MANUAL EKHWS150BA3V3 EKHWS200BA3V3 EKHWS300BA3V3 EKHWS200BA3Z2 EKHWS300BA3Z2 Domestic hot water tank for air to water heat pump system 4PEN610457 1 book Page 1 Tuesday February 25 2020 4 15...

Page 2: ...2 1 4PEN610457 1 book Page 1 Tuesday February 25 2020 4 15 PM...

Page 3: ...EKHWS150BA3V3 EKHWS200BA3V3 EKHWS200BA3Z2 EKHWS300BA3V3 EKHWS300BA3Z2 Domestic hot water tank for air to water heat pump system Installation manual READ THESE INSTRUCTIONS CAREFULLY BEFORE INSTALLATI...

Page 4: ...t guarantee neither good operation nor reliability of the system For those reasons Daikin cannot give warranty of the system in such case The equipment is not intended for use in a potentially explosi...

Page 5: ...leak water can not cause any damage to the installation space and surroundings Installing the domestic hot water tank 1 Check if all domestic hot water tank accessories see Accessories on page 1 are...

Page 6: ...e sure to firmly fix the power supply cord onto the 3 way valve body with a field supplied cable tie like in illustration below 10 Perform the wiring in the indoor unit in accordance with the followin...

Page 7: ...nd X4M to the earthing screw 7 Connect the booster heater power supply and thermal protection cable field supply to terminal X4M earth 1 2 and X2M 13 14 8 Connect the booster heater power supply cable...

Page 8: ...hard water To do so drain the domestic hot water tank remove the booster heater from the domestic hot water tank and immerse in a bucket or similar with lime removing product for 24 hours A4P K6M F2B...

Page 9: ...ON The main water supply is off Check that all shut off valves of the water circuit are completely open POSSIBLE CAUSES CORRECTIVE ACTION The thermal cut out s has have operated Check and reset button...

Page 10: ...NOTES 4PEN610457 1 book Page 1 Tuesday February 25 2020 4 15 PM...

Page 11: ...NOTES 4PEN610457 1 book Page 2 Tuesday February 25 2020 4 15 PM...

Page 12: ...4P610547 1 2020 01 Copyright Daikin 4PEN610457 1 book Page 1 Tuesday February 25 2020 4 15 PM...

Reviews: