![Daikin EKHWP300B Installation And Operating Instructions Manual Download Page 19](http://html1.mh-extra.com/html/daikin/ekhwp300b/ekhwp300b_installation-and-operating-instructions-manual_3349201019.webp)
4
x
Set-up and installation
Daikin EKHWP/EKHWC/EKHWD
Daikin High-efficiency hot water storage tank
008.1618744 – 03/2017
Installation and operating instructions
19
EKHWP / EKHWC hot water storage tank with solar
system
●
Installing a KFE filling connection (accessory KFE BA):
a)
With
solar system:
on the connection bracket of the
regulation and pump unit (EKSRPS3).
b)
With
solar system:
on the filling and draining
connection of the Daikin EKHWP / EKHWC.
●
Connect the
filling hose
with backflush prevention (1/2")
to
the previously installed
KFE filling connection
.
●
Only with
solar system:
Adjust the valve insert on the connecting angle so that the
path to the filling hose is opened (fig. 4-5).
●
Open the KFE cock on the
KFE filling connection
and the
cold water inlet and fill the storage tank for the Daikin
EKHWP/EKHWC
until water comes out of the safety
overflow
(fig. 4-5, item 5).
Fig. 4-5
Filling the buffer storage tank - with KFE filling connection
Summary of Contents for EKHWP300B