background image

EKHBRD011~0Y17

Indoor unit for air to water heat pump system

4P402191-1B – 2017.09

Installation manual

6

Design of the hydraulic system

When designing the hydraulic system, always consult 

"Typical

application examples" on page 2

 for references.

When designing the hydraulic system always consider the available
external static pressure of the EKHBRD* unit.

The pump will adjust its rpm (rotations per minute) as to control a
fixed 

T between return and leaving water temperature.

This external static pressure-graph is valid at maximum pump rpm.

Simultaneous operation of the auxiliary boiler and the
EKHBRD* unit is 

NOT allowed

.

Pay special attention to the control of the circulation
pump of the auxiliary boiler. This pump should not
operate simultaneously with the EKHBRD* unit.
A simultaneous operation of both systems will risk the
plate heat exchanger of the EKHBRD* unit to freeze-
up!

External static pressure (kPa)

Flow (l/min)

Without 3-way valve

Including 3-way valve

Maximum external static pressure if 

T = 10°C

Maximum external static pressure if 

T = 5°C

10

20

30

40

50

60

70

80

0

19

17

15

21 23 25 27 29 31 33 35 37 39 41 43 45 47

flow [l/min]

ESP 

[kP

a

]

90

100

16 kW

14 kW

14 kW

11 kW

11 kW

16 kW

NOTE

When replacing an old gas or fuel oil boiler by a air to
water heat pump system (EKHBRD*):

please always check the specifications of the
pump of the old unit;

if the external static pressure of that pump is
higher than the external static pressure of the air
to water heat pump system, please install an
additional pump with higher external static
pressure in combination with a balancing bottle.

Example of a high external static pressure system

3

4

2

1

1

Air to water heat pump system (EKHBRD*)

2

Balancing bottle

3

High external static pressure pump (field supply)

4

High external static pressure system

3

3

4

5 6

2

1

8

7

10

11

A

B

9

12 13

13

13

C

C1

1

Outdoor unit

2

Indoor unit

3

Electronic expansion valve

4

Refrigerant heat exchanger

5

Water heat exchanger

6

Pump

7

Compressor

8

Balancing bottle (field supply)

9

Pump (field supply)

10

Collector (field supply)

11

By-pass valve (field supply)

12

Shut off valve (field supply)

13

Radiator (field supply)

C1

Remote controller

A

Installation place

B

Living room

C

Example of a high static pressure system: 
radiators installed in series or very small piping

4PEN402191-1B_2017_09.book  Page 6  Friday, October 6, 2017  7:03 PM

Summary of Contents for EKHBRD014ADV17

Page 1: ...ION MANUAL EKHBRD011ADV17 EKHBRD014ADV17 EKHBRD016ADV17 EKHBRD011ADY17 EKHBRD014ADY17 EKHBRD016ADY17 Indoor unit for air to water heat pump system 4PEN402191 1B_2017_09 book Page 1 Friday October 6 2017 7 03 PM ...

Page 2: ...708 62 15 12 13 14 14 14 14 PS LV HV HV LV PS LV HV PS 552 37 227 7 120 143 69 3 3 11 8 11 6 10 2 1 24 45 16 31 10 4 9 16 5 8 10 10 11 11 6 7 1x 1x 6x 1x 1x 1x 1 2 3 1x 4 6 2x 8 2x 7 2x 9 1x 10 11 2x 12 5 1x 13 30 50 LV HV PS LV HV PS LV PS HV 1x 14 1 2 4 3 4PEN402191 1B_2017_09 book Page 1 Friday October 6 2017 7 03 PM ...

Page 3: ... e giudicato positivamente da B secondo il Certificato C 07 ËÌ ˆÛË fi ˆ Î ıÔÚ ÂÙ È ÛÙÔ A Î È ÎÚ ÓÂÙ È ıÂÙÈÎ fi ÙÔ B Û ÌÊˆÓ Ì ÙÔ ÈÛÙÔ ÔÈËÙÈÎfi C 08 Nota tal como estabelecido em A e com o parecer positivo de B de acordo com o Certificado C 09 Примечание как указано в A и в соответствии с положительным решением B согласно Свидетельству C 10 Bemærk som anført i A og positivt vurderet af B i henhold ti...

Page 4: ... 38 Annex 39 The English text is the original instruction Other languages are translations of the original instructions INTRODUCTION General information Thank you for purchasing this unit This appliance is intended to be used by expert or trained users in shops in light industry and on farms or for commercial and household use by lay persons The unit is the indoor part of the air to water ERSQ or ...

Page 5: ...ndoor unit Refer to the demand PCB installation manual for further details Refer to the wiring diagram or connection diagram for connecting this PCB to the unit Scope of this manual This installation manual describes the procedures for handling installing and connecting all EKHBRD indoor unit models Model identification Indoor unit Typical application examples The application examples given below ...

Page 6: ...emote controller installed with the unit and the external room thermostat installed in the living room There is only a room thermostat on off control There is no smart logic functionality for space heating When there is simultaneous demand of space heating and domestic hot water the domestic hot water operation is performed according to the minimum and maximum timer operation 1 Outdoor unit 10 Col...

Page 7: ...ation Refer to the chapter Multiple set point control on page 29 for more information about the configuration of your system 1 Outdoor unit 14 By pass valve field supply 2 Indoor unit 3 Electronic expansion valve 15 FCU Fan coil unit or FWXV optional 4 Refrigerant heat exchanger 16 Shut off valve field supply 5 Water heat exchanger 17 Radiator field supply 6 Pump 18 Mixing valve field supply 8 Dom...

Page 8: ... room 3 3 4 5 6 8 2 1 11 M 9 12 12 7 C1 15 16 13 13 20 20 19 10 A B 14 17 18 Boiler thermostat Boiler thermostat C Auxiliary contact normal closed th Heating only room thermostat K1A Auxiliary relay for activation of EKHBRD unit field supply K2A Auxiliary relay for activation of boiler field supply NOTE Make sure that auxiliary contact C has sufficient differential or time delay so as to avoid fre...

Page 9: ...0 0 19 17 15 21 23 25 27 29 31 33 35 37 39 41 43 45 47 flow l min ESP kPa 90 100 16 kW 14 kW 14 kW 11 kW 11 kW 16 kW NOTE When replacing an old gas or fuel oil boiler by a air to water heat pump system EKHBRD please always check the specifications of the pump of the old unit if the external static pressure of that pump is higher than the external static pressure of the air to water heat pump syste...

Page 10: ...ust be cleaned on a regular base See Maintenance activities on page 35 12 Expansion vessel 12 l 13 Manometer The manometer allows readout of the water pressure in the water circuit 14 Pump The pump circulates the water in the water circuit 15 Pressure relief valve The pressure relief valve prevents excessive water pressure in the water circuit by opening at 3 bar and discharging some water 16 Serv...

Page 11: ...9 Compressor cable entry 20 Interface relay K1A 21 Wiring bridges 22 Fuse F1 only Y17 23 Fuse F2 only Y17 Functional diagram 8 12 20 19 14 13 1 3 5 9 16 17 18 10 11 6 7 21 2 8 12 20 19 14 13 1 2 3 4 6 16 17 18 10 9 11 23 21 22 7 NOTE The electrical connection diagram can be found on the inside of the switch box cover 1 Outdoor unit 16 Fill valve field supply 2 Indoor unit 17 Shut off valve water i...

Page 12: ...in order to prevent damage during transport Unpack the indoor unit completely according to the instructions mentioned on the unpacking instructions sheet Check if all indoor unit accessories see Accessories on page 7 are enclosed Installing the indoor unit For connecting piping and electrical cables knock out holes are provided at the back of the unit To punch a knock out hole hit on it with a ham...

Page 13: ...3 Grommet 2 Burr 4 Putty or insulation materials field supply The weight of the unit is approximately 145 kg At least two persons are required to lift the unit Use the plates delivered with the unit to lift the unit Standard installation location of the optional domestic hot water tank is on top of the indoor unit If available service space to left and or right side is limited carefully consider a...

Page 14: ...oration panel s back to the unit using the appropriate screws 3 Stick the top plate insulation accessory at the inside of the top decoration panel according to the figure below 4 Fix the top decoration panel on top of the unit using the appropriate screws In case a domestic hot water tank optional is installed refer to the domestic hot water tank installation manual It is very important to keep go...

Page 15: ...low points of the system to permit complete drainage of the circuit during maintenance One drain valve in the indoor unit is provided to drain the water from the indoor unit water system Make sure to provide a proper drain for the pressure relief valve to avoid any water coming into contact with electrical parts Air vents must be provided at all high points of the system The vents should be locate...

Page 16: ...pace heating radiator loop is controlled by remotely controlled valves it is important that this minimum water volume of 20 l is kept even if all the valves are closed Example 1 Outdoor unit 10 Radiator field supply 2 Indoor unit 11 Electronic expansion valve 3 Refrigerant heat exchanger C1 Remote controller 4 Water heat exchanger M1 M3 Individual motorized valve to control loop radiators field su...

Page 17: ...sing non brass metallic piping make sure to insulate both materials from each other to prevent galvanic corrosion Because brass is a soft material use appropriate tooling for connecting the water circuit Inappropriate tooling will cause damage to the pipes Precautions when connecting field piping and regarding insulation The complete water circuit inclusive all piping must be insulated to prevent ...

Page 18: ...t comply with relevant European and national regulations Be sure to install the required fuses as mentioned on the electrical wiring diagram The field wiring must be carried out in accordance with the wiring diagram supplied with the unit and the instructions given below Never squeeze bundled cables and make sure that it does not come in contact with the piping and sharp edges Make sure no externa...

Page 19: ...n the radio waves a distance of 1 meter may not be sufficient to eliminate the noise Item Cable bundle Description Required number of conductors Maximum running current In case of normal kWh rate power supply installation 1 3 1 PS Normal kWh rate power supply 2 GND 4 GND b b Refer to the nameplate on the indoor unit In case of benefit kWh rate power supply installation 1 3 1 PS Normal kWh rate pow...

Page 20: ...r supply the electricity company is allowed to interrupt power supply to the equipment for certain periods of time demand that the equipment only consumes a limited amount of electricity during certain periods of time The indoor unit is designed to receive an input signal by which the unit switches into forced off mode At that moment the unit compressors will not operate NOTE The wiring for connec...

Page 21: ...ield supply 1 2 3 X3M 7 8 X2M 8 9 X1M L N L N 2 4 1 3 5 3 L N 2 1 4 3 4 3 L N 2 1 S1S S1S S1S 6 04 1 1 2 3 L N 2 1 3 L N 2 1 4 3 4 4 4 3 L N L N 2 1 S1S S1S S1S 6 04 2 X2M 10 11 8 9 6 6 1 Benefit kWh rate power supply box 2 Receiver controlling the signal of the electricity company 3 Benefit kWh rate power supply 4 Voltage free contact to indoor unit 5 Normal kWh rate power supply 6 Fuse field sup...

Page 22: ...supply voltage on the local supply panel The voltage must correspond to the voltage on the identification label of the unit 10 Air purge valve Make sure the air purge valve of the heat pump is open at least 2 turns Make sure the air purge valve of the heater kit is open at least 2 turns See installation manual of the heater kit 11 Shut off valves Make sure that the shut off valves are correctly in...

Page 23: ...em and will be displayed in the temperature read out mode See also 9 Automatic temperature compensation on page 24 for compensation values for leaving water temperature and domestic hot water temperature 0 03 Status defines whether the ON OFF instruction can be used in the schedule timer for space heating The schedule timer for space heating can be programmed on 2 different ways based on the tempe...

Page 24: ... 19 C 18 C 19 C 22 C 21 C 62 C 62 C 19 19 C 62 62 C 19 C 62 C 19 19 C 62 62 C 19 C 62 C 19 19 C 62 62 C 19 C 62 C 65 C 64 C 6 30 3 57 57 C 57 C 60 60 C 60 C Method 2 0 03 0 Space heating based on ON OFF instruction During operation When the schedule timer switches space heating OFF the controller will be switched off operation LED will stop working Note that this has no influence on the domestic w...

Page 25: ... will result in warmer water and vice versa The unit has a floating set point Activating this operation will result in a lower power consumption than use with a manually fixed leaving water set point During weather dependent operation the user has the possibility to shift up or down the target water temperature by a maximum of 5 C This is the temperature difference between the temperature set poin...

Page 26: ...eat pump it is supplementary to the remote controller room thermostat function To have a good control of the system and avoiding frequent ON OFF it is advised to use the automatic weather dependent set point operation 6 02 Heater kit Once installed you can activate the heater kit by changing field setting 6 02 1 From that moment on the heat pump system will take the heater kit into account whilst ...

Page 27: ...bient temperature 4 C For both cases the pump will operate and if leaving or return water 5 C for 5 minutes the unit will start up to prevent too low temperatures It is advised to enable freeze up prevention if the indoor unit is located in a colder ambient room e g garage to prevent water freeze up 9 Automatic temperature compensation If needed it is possible to adjust some thermistor value of th...

Page 28: ...t point interval minimum stop time of domestic water heating Changing the timer values can have an impact on space heating and domestic water heating heat up timers The default values are proposed but can be changed depending on the complete system installation For a detailed explanation about simultaneous request of space heating and domestic water heating see chapter Simultaneous demand of space...

Page 29: ...E 04 1 or 2 Pump operation of 20 minutes 3 way valve in space heating mode if 6 00 1 Pump operation of 10 minutes 3 way valve in domestic hot water heating mode NOTE Do not forget to restore the field setting E 04 to the default value when commissioning is finished A Operation Space heating Domestic water heating B Domestic hot water reheat thermo on request C Domestic hot water tank temperature D...

Page 30: ...perature F Domestic hot water lower limit temperature G Domestic hot water upper limit temperature maximum possible storage temperature b 03 H Domestic hot water reheat minimum temperature b 00 J Domestic hot water reheat maximum temperature b 01 K External room thermostat set point L External room thermostat ON OFF hysteresis ON ON OFF OFF A B C H J L 75 C 35 C X C X C ON G F OFF D E ON OFF K K A...

Page 31: ...hot water reheat minimum temperature b 00 J Domestic hot water reheat maximum temperature b 01 K Remote controller thermostat set point ON ON OFF OFF A B C H J K 75 C 35 C 3 0 C 0 5 C 0 5 C ON G F OFF D E ON OFF A Operation Space heating Domestic water heating B Domestic hot water storage thermo on request C Domestic hot water tank temperature D Room temperature thermo on request E Remote controll...

Page 32: ...oil is open The heat pump will deliver water with a higher temperature which is needed for production of the domestic hot water At that time the lower temperature appliances have to be protected against the higher water temperature by a temperature reducing valve The configuration of pattern A allows 2 space heating set points and one same as in the classic design domestic hot water set point The ...

Page 33: ...t as replacement of the remote controller room thermostat function may be used The remote controller water temperature value is ignored when pattern A is active It is the installers responsibility to make sure no unwanted situations can occur e g too high water temperatures towards floor heating loops etc It is the installers responsibility to make sure the water circuit is well balanced e g when ...

Page 34: ...nt Field setting Thermo status Space 0 65 C Remote controller OFF ON OFF OFF OFF Space 1 45 C A 03 OFF ON OFF ON ON OFF Space 2 35 C A 04 OFF ON OFF OFF ON ON Resulting heat pump water OFF 65 C 45 C 45 C 35 C NOTE Leaving water control is not allowed for pattern B It is the installers responsibility to make sure no unwanted situations can occur e g too high water temperatures towards floor heating...

Page 35: ...ambient temperature Lo_Ti 70 25 80 1 C 03 Set point at high ambient temperature Hi_Ti 45 25 80 1 C 4 Disinfection function 00 Status disinfection operation 1 ON 0 1 01 Disinfection operation day selection Fri Mon Sun 02 Disinfection operation start time 23 00 0 00 23 00 1 00 hour 5 Automatic setback and disinfection set point 00 Set point disinfection operation temperature 70 60 75 5 C 01 Disinfec...

Page 36: ...temperature 70 45 75 1 C 04 Automatic maximum domestic hot water storage temperature 70 55 75 1 C C Leaving water temperature limits 00 Set point leaving water maximum temperature 80 37 80 1 C 01 Set point leaving water minimum temperature 25 25 37 1 C 02 Not applicable Do not change the default value 20 18 22 1 C 03 Not applicable Do not change the default value 5 5 18 1 C d Domestic water heatin...

Page 37: ... user interface will return to normal mode after 10 seconds or by pressing the button once To test the space heating operation push the button to start the test run operation 4 The test run operation will end automatically after 30 minutes or when reaching the set temperature The test run operation can be stopped manually by pressing the button once If there are misconnections or malfunctions an e...

Page 38: ...recting certain troubles which may occur in the unit This troubleshooting and related corrective actions may only be carried out by your local Daikin technician General guidelines Before starting the troubleshooting procedure carry out a thorough visual inspection of the unit and look for obvious defects such as loose connections or defective wiring When a safety device was activated stop the unit...

Page 39: ...eaning Make sure there is no air in the system purge air Check on the manometer that there is sufficient water pressure The water pressure must be 0 3 bar water is cold 0 3 bar water is hot Make sure that the expansion vessel is not broken The water volume in the installation is too low Make sure that the water volume in the installation is above the minimum required value refer to Checking the wa...

Page 40: ...ror Contact your local dealer E1 Compressor PCB error Contact your local dealer E3 High pressure error S1PH Check wiring connections on outdoor unit and indoor unit Make sure the circuit is filled with water no air inside e g is the air purge open Make sure the domestic hot water tank is filled with water Make sure water flow is possible open all valves in the circuit Make sure the water filter is...

Page 41: ...Ø15 9 5 8 inch Ø15 9 5 8 inch Ø15 9 5 8 inch Expansion vessel volume l 12 12 12 12 12 12 maximum working pressure MWP bar 4 4 4 4 4 4 Pump type DC motor DC motor DC motor DC motor DC motor DC motor no of speed inverter controlled inverter controlled inverter controlled inverter controlled inverter controlled inverter controlled Sound pressure level a dBA 40 dBA 40 dBA 43 dBA 43 dBA 46 dBA 46 dBA I...

Page 42: ... 7 04 1 6 01 1 page 23 What type of appliance do you have No Blank display Push the button You selected permission level 3 on remote controller 0 00 3 page 20 You selected automatic leaving water control page 22 A 03 or and A 04 Water temperature A 03 or and A 04 Yes You selected multiple set point control operation pattern A 7 02 0 and 7 03 1 or and 7 04 1 page 23 Shift value Push ON OFF What typ...

Page 43: ...operate depending on settings request icon will start blinking with 0 5 second intervals Domestic hot water production will start immediately icon will start blinking with 1 second intervals Choose start time 1 03 It is not possible to see when actual domestic hot water is made If you want to disable reheat function and at the same time domestic hot water is being produced in reheat operation you ...

Page 44: ...xternal room thermostat control Yes Yes Yes 2 No Operation will switch to space heating Operation will switch to space heating Timer d 02 15 minutes passed since 2 No Space heating operation will continue till timer finished Yes Remote controller room thermostat control Storage setpoint b 03 reached No Room temperature Tset 3 C No Timer d 01 30 minutes passed since 1 Yes 2 Yes Yes No Yes Operation...

Page 45: ...4PEN402191 1B_2017_09 book Page 1 Friday October 6 2017 7 03 PM ...

Page 46: ...4PEN402191 1B_2017_09 book Page 2 Friday October 6 2017 7 03 PM ...

Page 47: ...V1 Y1 5 5 4PEN402191 1B_2017_09 book Page 1 Friday October 6 2017 7 03 PM ...

Page 48: ...4P402191 1B 2017 09 Copyright 2015 Daikin 4P402191 1 B 0000000V 4PEN402191 1B_2017_09 book Page 1 Friday October 6 2017 7 03 PM ...

Reviews: