background image

EKHBRD011~Y1

Indoor unit for air to water heat pump system and options

4PW60971-1

Operation manual

10

Schedule timer operation

In schedule timer operation, the installation is controlled by the
schedule timer. The actions programmed in the schedule timer will be
executed automatically.

The schedule timer is enabled (

p

 icon displayed) or disabled (

p

 icon

not displayed) by pressing the 

pr

 button.

Space heating

Refer to "Programming space heating" on page 12.

Five actions per day of the week can be programmed, totalling 35
actions.

The space heating schedule timer can be programmed in 2 different
ways: based on the temperature set point (both leaving water
temperature and room temperature) and based on the ON/OFF
instruction.

The desired method is set through 

fi

eld setting. Refer to the chapter

"Field settings" on page 15 for a detailed description how to set one
or more 

fi

eld settings.

[0-03]

 Status: de

fi

nes whether ON/OFF instruction can be used

in the schedule timer for space heating.

In the following tables both methods on how to interpret the schedule
timer are shown.

Operation example

:  Schedule timer based on temperature set

points.

When setback function is enabled, the setback operation will have
priority over the scheduled action in the schedule timer.

NOTE

By default space heating based on temperature set
point (method 1) is enabled, so only temperature shifts
are possible (no ON/OFF instruction).

Advantage of this method is that you can simply switch
off the space heating operation by pushing the 

y

button without disabling the automatic domestic hot
water storage operation (e.g. during summertime
when no space heating is required).

Method 1
[0-03]=1 (default)

Space heating based on temperature set point

(a)

(a) For leaving water temperature and/or room temperature

During operation

During schedule timer operation the operation LED is lit 
continuously.

When pushing 
the 

y

 button

The schedule timer for space heating will stop and will 
not start again.
The controller will be switched off (operation LED will 
stop working).
However, the schedule timer icon will stay displayed 
which means that the domestic water heating stays 
enabled.

When pushing 
the 

r

/

p

 button

The schedule timer for space heating 

and

 domestic 

water heating along with the quiet mode will be stopped 
and will not start again.
The schedule timer icon will not be displayed anymore.

1

Schedule timer

2

Setback function

3

When both setback function and schedule timer are enabled

A

Setback function

t

Time

T

Temperature set point

Room temperature

Leaving water temperature

Method 2
[0-03]=0

Space heating based on ON/OFF instruction

During operation

When the schedule timer switches space heating OFF, 
the controller will be switched off (operation LED will stop 
working). Note that this has no in

fl

uence on the domestic 

water heating.

When pushing 
the 

y

 button

The schedule timer for space heating will stop (when 
active at that moment) and will start again at the next 
scheduled ON function.
The "last" programmed command overrules the 
"preceding" programmed command and will remain 
active until the "next" programmed command occurs.

Example: imagine the actual time is 17:30 and actions 
are programmed at 13:00, 16:00 and 19:00. The "last" 
programmed command (16:00) overruled the 
"previous" programmed command (13:00) and will 
remain active until the "next" programmed command 
(19:00) occurs.

So in order to know the actual setting, one should consult 
the last programmed command. It is clear that the "last" 
programmed command may date from the day before. 
Refer to "Consulting programmed actions" on page 14.
The controller will be switched off (operation LED will 
stop working).
However the schedule timer icon will stay displayed 
which means that the domestic heating stays enabled.

When pushing 
the 

r

/

p

 button

The schedule timer for space heating 

and

 domestic 

water heating along with the quiet mode will be stopped 
and will not start again.
The schedule timer icon will not be displayed anymore.

T

t

6:30

9:00

16:00

0:30

19

19

°

C

19

19

°

C

19

19

°

C

22

22

°

C

21

21

°

C

62

62

°

C

62

62

°

C

62

62

°

C

65

65

°

C

64

64

°

C

62

°

C

19

°

C

19

°

C

19

°

C

22

°

C

21

°

C

62

°

C

62

°

C

65

°

C

64

°

C

0:30

1

T

t

18

18

°

C

57

57

°

C

57

°

C

18

°

C

A

5:00

5:00

23:00

23:00

5:00

23:00

2

T

t

5:00

9:00

16:00

23:00

19

19

°

C

18

18

°

C

19

19

°

C

22

22

°

C

21

21

°

C

62

62

°

C

60

60

°

C

62

62

°

C

65

65

°

C

64

64

°

C

60

°

C

19

°

C

18

°

C

19

°

C

22

°

C

21

°

C

62

°

C

62

°

C

19

19

°

C

62

62

°

C

19

°

C

62

°

C

19

19

°

C

62

62

°

C

19

°

C

62

°

C

19

19

°

C

62

62

°

C

19

°

C

62

°

C

65

°

C

64

°

C

6:30

3

57

57

°

C

57

°

C

60

60

°

C

60

°

C

Summary of Contents for EKHBRD014ABV1

Page 1: ...OPERATION MANUAL EKHBRD011ABV1 EKHBRD014ABV1 EKHBRD016ABV1 EKHBRD011ABY1 EKHBRD014ABY1 EKHBRD016ABY1 Indoor unit for air to water heat pump system and options...

Page 2: ...es or lack of experience and knowledge unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety Children should be supervised to...

Page 3: ...e rp button See Automatic storage on page 7 The p icon will display Hot water will be produced at next scheduled action When water heat up starts the w icon will be blinking 1 second interval Manual s...

Page 4: ...used For installation purposes only 13 NOT AVAILABLE n This icon is displayed whenever a non installed option is addressed or a function is not available A function not available can mean insufficien...

Page 5: ...seconds the display will show to the actual room temperature 32 QUIET MODE BUTTON s This button enables or disables quiet mode If the controller is set to permission level 2 or 3 refer to Field setti...

Page 6: ...oor temperatures will result in warmer water and vice versa The unit has a floating set point Activating this operation will result in a lower power consumption than use with a manually fixed leaving...

Page 7: ...k function is turned ON 1 or OFF 0 2 01 Start time time at which setback is started 2 02 Stop time time at which setback is stopped 5 02 Leaving water setback temperature temperature drop Domestic wat...

Page 8: ...storage temperature set point is reached It is a one time hot water making feature Selecting manual storage operation for domestic water heating 1 Push and hold the w button for 5 seconds to activate...

Page 9: ...er Field settings on page 15 for a detailed description how to set one or more field settings 4 00 Status defines whether the disinfection function is turned ON 1 or OFF 0 4 01 Operation interval day...

Page 10: ...multaneous demand of space heating and domestic water heating The unit can not perform domestic water heating and space heating at the same time If both modes are requested at the same time the unit w...

Page 11: ...eating stays enabled When pushing the r p button The schedule timer for space heating and domestic water heating along with the quiet mode will be stopped and will not start again The schedule timer i...

Page 12: ...tion 3 When both setback function and schedule timer are enabled A Setback function B ON OFF instruction t Time T Temperature set point Room temperature Leaving water temperature t 18 18 C 60 60 C 60...

Page 13: ...e repeated on a weekly basis In the domestic water heating and quiet mode program depending on remote controller model 4 or 5 actions can be programmed per mode The same actions are repeated on a dail...

Page 14: ...s the button for 5 seconds to store the programmed actions If the button is pressed when action number 3 is displayed actions 1 2 and 3 are stored but 4 and 5 are deleted You automatically return to s...

Page 15: ...step 2 by pressing the pr button 5 Press the and pr buttons simultaneously for 5 seconds After 5 seconds the display will show the next day e g 2 if 1 was selected first This indicates that the day h...

Page 16: ...Press the z button for a minimum of 5 seconds to enter FIELD SET MODE The icon 3 will be displayed The current selected field setting code is indicated 2 with the set value displayed to the right 1 2...

Page 17: ...10 20 1 C 02 Set point at low ambient temperature Lo_Ti 70 25 80 1 C 03 Set point at high ambient temperature Hi_Ti 45 25 80 1 C 4 Disinfection function 00 Status disinfection operation 1 ON 0 1 01 D...

Page 18: ...age temperature 70 45 75 1 C 04 Automatic maximum hot water tank storage temperature 70 55 75 1 C C Leaving water temperature limits 00 Installation related setting 80 37 80 1 C 01 Installation relate...

Page 19: ...yourself the dismantling of the system treatment of the refrigerant of oil and other parts must be done by a qualified installer in accordance with relevant local and national legislation Units must b...

Page 20: ...NOTES...

Page 21: ...NOTES...

Page 22: ...NOTES...

Page 23: ......

Page 24: ...4PW60971 1 Copyright 2010 Daikin...