EKHBH/X008BB
Indoor unit and options for air to water heat pump system
4PW62571-1A – 05.2011
Operation manual
8
3
Switch on the unit by pushing the
button.
The operation LED lights up.
Selection and setting of domestic water heating (
)
1
Use the
button to activate domestic water heating (
).
Icon
appears on the display.
2
Use the
or
button to display the actual
temperature set point and subsequently, to set the correct
temperature.
The actual temperature set point only appears on the display
after pressing one of the buttons
or
. If no button is
pressed for 5 seconds, the temperature set point will
automatically disappear from the display again.
Temperature range for domestic water heating:
-
For EKHW* only: 30°C to 78°C
-
For EKHTS only: 30°C to 60°C
3
Press the
button to deactivate domestic water heating (
).
Icon
disappears from the display.
Selecting powerful domestic water heating operation
(1)
1
Press
for 5 seconds to activate powerful domestic water
heating operation.
-
For EKHW* only: Icons
and
start flashing
(2)
.
-
For EKHTS only: Icons
and
start flashing
(3)
.
Powerful domestic water heating is deactivated automatically
when the set point for the domestic hot water is reached.
Selecting quiet mode operation (
)
1
Use the
button to activate quiet mode operation (
).
Icon
appears on the display.
If the controller is set in permission level 2 or 3 (refer to
"5. Field
settings" on page 13
), the
button will not be operable.
Selecting weather dependent set point operation
1
Press the
button to select weather dependent set point
operation.
Icon
appears on the display as well as the calculated water
temperature set point based on the outdoor temperature.
2
Use the
or
button to display the actual shift value
and subsequently, to set the correct value.
The shift value only appears on the display after pressing one of
the buttons
or
. If no button is pressed for 5
seconds, the shift value will automatically disappear from the
display again.
Range for the shift value: –5°C to +5°C
Displaying actual temperatures
1
Push the
button for 5 seconds.
The
icon and the entering water temperature are displayed.
The icons
and
are flashing.
2
Use the
and
buttons to display:
If no button is pressed for 5 seconds, the controller leaves the
display mode.
Schedule timer operation
In schedule timer operation, the installation is controlled by the
schedule timer. The actions programmed in the schedule timer will be
executed automatically.
The schedule timer always follows the last command until a new
command is given. This means that the user can temporarily overrule
the last executed programmed command by manual operation (Refer
to
"Manual operation" on page 7
). The schedule timer will regain
control over the installation as soon as the next programmed
command of the schedule timer occurs.
The schedule timer is enabled ( icon displayed) or disabled ( icon
not displayed), by pressing the
button.
To set up the SCHEDULE TIMER refer to chapter
"4.7. Programming
and consulting the schedule timer" on page 9
.
INFORMATION
When the unit is connected to an external room
thermostat, buttons
and
are not operable and the
icon
is shown. In this case, the external room
thermostat switches the unit on or off and determines the
operation mode (space heating or space cooling).
INFORMATION
The domestic hot water set point set on the controller
is the actual domestic hot water set point ([4-03]=0, 1,
2, or 3) or the domestic hot water storage set point
([4-03]=4, or 5). See
"Domestic water heating
operation (
)" on page 6
.
INFORMATION
Remark that pushing the
button has no influence
on the domestic water heating. Domestic water
heating is only switched on or off by means of the
button.
(1) When the unit is configured for restricted power supply condition mode,
see
"Appendix" on page 22
.
(2) Only applicable for tank with built-in electrical booster heater (EKHW*).
(3) Only applicable for tank without electrical booster heater (EKHTS).
Flashing icon(s)
Meaning
or
The entering water temperature
or
and
The outgoing water temperature after plate heat
exchanger
or
and
The outgoing water temperature after backup
heater
The liquid refrigerant temperature
The outdoor temperature
The domestic hot water temperature
INFORMATION
■
Only use the
button to enable or disable the
schedule timer. The schedule timer overrules the
button. The
button only overrules the schedule
timer until the next programmed action.
■
If the auto restart function is disabled, the schedule
timer will not be activated when power returns to the
unit after a power supply failure. Press the
button
to enable the schedule timer again.
■
When power returns after a power supply failure, the
auto restart function reapplies the user interface
settings at the time of the power supply failure.
It is therefore recommended to leave the auto restart
function enabled.
■
The programmed schedule is time driven. Therefore, it
is essential to set the clock and the day of the week
correctly. Refer to
"Setting the clock" on page 6
.
■
Manually adjust the clock for summertime and
wintertime. Refer to
"Setting the clock" on page 6
.
■
A power failure exceeding 2 hours will reset the clock
and the day of the week. The schedule timer will
continue operation, but with a disordered clock. Refer
to
"Setting the clock" on page 6
to adjust the clock and
the day of the week.
■
The actions programmed in the schedule timer will not
be lost after a power failure so that reprogramming the
schedule timer is not required.