3 Operation

Operation manual

6

08S23DAV

Daikin Altherma – Low temperature split

4P499572-1 – 2017.06

INFORMATION

When  the  DHW  tank  mode  is  reheat,  the  risk  for  capacity
shortage  and  comfort  problem  is  significant.  In  case  of
frequent  reheat  operation,  space  heating  function  is
regularly interrupted.

3.4.2

Scheduled mode

In scheduled mode the DHW tank produces hot water corresponding
to a schedule. The best time to allow the tank to produce hot water is
at night, because the space heating demand is lower.

Example: 

t

60°C

00:00

07:00

50°C

15°C

40°C

14:00

21:00

1

2

3

4

5

Tt

T

t

DHW tank temperature

t

Time

3.4.3

Sch reheat mode

In  scheduled  +  reheat  mode,  the  domestic  hot  water  control  is  the
same  as  in  scheduled  mode.  However,  when  the  DHW  tank
temperature drops below a preset value (=reheat tank temperature –
hysteresis  value;  example:  35°C),  the  DHW  tank  heats  up  until  it
reaches  the  reheat  set  point  (example:  45°C).  This  ensures  that  a
minimum amount of hot water is available at all times.

Example: 

t

Tt

60°C

00:00

07:00

50°C

45°C

15°C

14:00

21:00

35°C

1

2

4

5

3

T

t

DHW tank temperature

t

Time

3.4.4

Using DHW powerful operation

Powerful  operation  allows  the  domestic  hot  water  to  be  heated  by
the anti-legionella heater. Use this mode on days when there is more
hot water usage than usual.

Activate or deactivate Powerful operation as follows:

1

Go to [5.2]: Tank > Powerful operation

2

Turn powerful operation Off or On.

3.5

Advanced usage

The  amount  of  information  you  can  read  out  in  the  menu  structure
depends on your user permission level:

▪ User: Standard mode

▪ Advanced user: You can read out more information

3.5.1

To change the user permission level

You can change the user permission level as follows:

1

Go to [B]: User profile

2

Enter the applicable code for the user permission.

▪ Move the cursor from left to right.

▪ Browse  through  the  list  of  digits  and  change  the

selected digit.

▪ Confirm the pincode and proceed.

User pin code

The User pin code is 

0000

.

Advanced user pin code

The Advanced user pin code is 

1234

. Additional menu items for the

user are now visible.

3.6

Schedule screen: Example

This  example  shows  how  to  set  a  room  temperature  schedule  in
heating mode for the main zone.

INFORMATION

The procedures to program other schedules are similar.

To program the schedule

Example: 

You want to program the following schedule:

Mon

Sat

Wed

Fri

Thu

Tue

Sun

User defined 1

Prerequisite: 

The  room  temperature  schedule  is  only  available  if

room  thermostat  control  is  active.  If  leaving  water  temperature
control is active, you can program the main zone schedule instead.

1

Go to the schedule.

2

Clear the contents of the schedule (optional).

3

Program the schedule for Monday.

4

Copy the schedule to the other weekdays.

5

Program the schedule for Saturday and copy it to Sunday.

6

Give the schedule a name.

To go to the schedule:

1

Go to [1.2]: Room > Schedule.

2

Set scheduling to Yes.

3

Go to [1.3]: Room > Heating schedule.

To clear the contents of the schedule:

1

Select the name of the current schedule.

Mon

Sat

Wed

Fri

Thu

Tue

Sun

User defined 1

2

Select Delete.

Edit

Delete

3

Select OK to confirm.

Summary of Contents for EHVH08S23DAG

Page 1: ...Operation manual Daikin Altherma Low temperature split English Operation manual Daikin Altherma Low temperature split EHVH04S23DAV G EHVH08S23DAV G...

Page 2: ...e installer to inform you about the settings that he used to configure your system Check if he has filled in the installer settings tables If not request him to do so Keep the documentation for future...

Page 3: ...screen darkens Pressing any button or rotating any dial awakens the display The time of non interaction differs depending on the user permission level User or Advanced user 15 min Installer 1 h Dials...

Page 4: ...dditional zone h3 h1 h2 h1 Heat emitter type Underfloor heating Fancoil unit Radiator h2 Leaving water temperature setpoint h3 Room thermostat type External control Hidden Leaving water temperature co...

Page 5: ...ubmenu e Turn or press the left dial to go to the submenu 3 2 4 Detailed screen with values a b a Settings b Values Go through the list of settings Confirm changes and proceed Change the value Go to t...

Page 6: ...ge The amount of information you can read out in the menu structure depends on your user permission level User Standard mode Advanced user You can read out more information 3 5 1 To change the user pe...

Page 7: ...opy Edit Copy Result C is displayed next to the copied day 3 Select Tuesday Mon Sat Wed Fri Thu Tue Sun User defined 1 C 4 Select Paste Copy Paste C Result Mon Sat Wed Fri Thu Tue Sun User defined 1 C...

Page 8: ...on manual 8 EHVH04 08S23DAV Daikin Altherma Low temperature split 4P499572 1 2017 06 2 Select the Rename option Delete Rename 3 Browse through the character list and confirm the selected character 4 C...

Page 9: ...file 7 3 Holiday Activation From Till 7 4 Quiet Activation Schedule 7 5 Electricity price High Medium Low Schedule 7 2 Time date Hours Minutes AM PM Year Month Day Daylight savings time Format 8 Infor...

Page 10: ...ode Tips about DHW tank temperature Use a weekly schedule for your normal domestic hot water needs only in scheduled mode Program to heat up the DHW tank to a preset value Storage comfort higher DHW t...

Page 11: ...r type 6 3 Symptom The water at the tap is too cold Possible cause Corrective action You ran out of domestic hot water because of unusual high consumption If you immediately need domestic hot water ac...

Page 12: ...3DAV Daikin Altherma Low temperature split 4P499572 1 2017 06 8 Glossary DHW Domestic hot water Hot water used in any type of building for domestic purposes LWT Leaving water temperature Water tempera...