![Daikin EBHQ011BA6V3 Manual Download Page 6](http://html1.mh-extra.com/html/daikin/ebhq011ba6v3/ebhq011ba6v3_manual_3228531006.webp)
• Monobloc • EBHQ011-016BA6V3
• Daikin Altherma • Monobloc
86
2
Specifications
Power supply
hydraulic
component
Voltage range
Minimum
V
-10%
Maximum
V
+10%
Wiring connections
Connection type
for power supply hydraulic compartment
Quantity of wires
3G
Type of wires
Select diameter and type according to national and local regulations
Connection type
for power supply connection to optional sanitary tank + Q2L
Quantity of wires
3G
Type of wires
Select diameter and type according to national and local regulations
Type of wires
For more details on voltage range and current refer to installation manual
Connection type
for connection with R5T
Quantity of wires
Wire included in option EKHWS*
Type of wires
Wire included in option EKHWS*
Connection type
for connection with A3P
Quantity of wires
Depends on thermostat type, refer to installation manual
Type of wires
Select diameter and type according to national and local regulations
Type of wires
Voltage 230V / Maximum current: 100mA / Minimum 0.75mm²
Connection type
for connection with M2S
Quantity of wires
3G
Type of wires
Select diameter and type according to national and local regulations
Type of wires
Voltage 230V / Maximum current: 100mA / Minimum 0.75mm²
Connection type
for connection with M3S
Quantity of wires
3G or 4G
Type of wires
Select diameter and type according to national and local regulations
Type of wires
Voltage 230V / Maximum current: 100mA / Minimum 0.75mm²
Notes
Power supply compressor compartment is for compressor, fan, pump and controller
In accordance with EN/IEC 61000-3-11 (1), it may be necessary to consult the distribution network
operator to ensure that the equipment is connected only to a supply with Zsys (3) smaller than or equal
to Zmax.
Installer can reduce capacity of the heater from 6 to 3kW. The current is then reduced from 26 to 13A.
Instructions see installation manual.
Installer can reduce capacity of the heater from 6 to 3.5kW. The current is then reduced from 8.7 to
5A. Instructions see installation manual.
(1)European/International Technical Standard setting the limits for voltage changes , voltage
fluctuations and flicker in public low-voltage supply systems for equipment with rated current <= 75A.
(2) European/International Technical Standard setting the limits for harmonic currents produced by
equipment connected to public low-voltage systems with input current > 16A =< 75A per phase.
(3) System impedance
Power supply hydraulic compartment is for the electric heater. The optional domestic warm water tank
has a separate power supply.
Conditions: Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C)
2-4
ELECTRICAL SPECIFICATIONS
EBHQ011BA6V3
EBHQ014BA6V3
EBHQ016BA6V3