DP5HM BLOWER PERFORMANCE DATA
Speed Tap Switch 1 Switch 2
A
OFF
OFF
B
ON
OFF
C
OFF
ON
D
ON
ON
Electric Heat
DIP Switch Settings
Thermostat Switch 3
Switch 4
Single-Stage
N/A
ON
Two-Stage
N/A
OFF
DIP Switch Settings for
Single & Two-Stage Thermostat
Speed Tap Switch 5 Switch 6
A
OFF
OFF
B
ON
OFF
C
OFF
ON
D
ON
ON
Cooling/HP DIP Switch Settings
CFM
Switch 7
Switch 8
Plus 10%
ON
OFF
Normal
OFF
OFF
Minus 10%
OFF
ON
Speed Tap Adjustment
Through DIP Switches
CFM Output
for DIP Switch Combinations 1-2 (Electric Heat)
MODEL
SPEED
TAP
SWITCH
1
SWITCH
2
ELECTRIC
HEAT (CFM)
A
O
ff
O
ff
1050
B
On
O
ff
950
C
O
ff
On
825
D
On
On
700
A
O
ff
O
ff
1250
B
On
O
ff
1100
C
O
ff
On
1000
D
On
On
800
A
O
ff
O
ff
1250
B
On
O
ff
1100
C
O
ff
On
1000
D
On
On
800
A
O
ff
O
ff
1800
B
On
O
ff
1700
C
O
ff
On
1400
D
On
On
1225
A
O
ff
O
ff
1800
B
On
O
ff
1700
C
O
ff
On
1400
D
On
On
1225
DP5HM24
DP5HM30
DP5HM42
DP5HM48
DP5HM36
CFM Output
for DIP Switch Combinations 5-6 (Cooling/Heating)
MODEL
SPEED
TAP
SWITCH
5
SWITCH
6
COOLING/HP
CFM
A
O
ff
O
ff
1050
B
On
O
ff
950
C
O
ff
On
825
D
On
On
700
A
O
ff
O
ff
1250
B
On
O
ff
1100
C
O
ff
On
1000
D
On
On
800
A
O
ff
O
ff
1250
B
On
O
ff
1100
C
O
ff
On
1000
D
On
On
800
A
O
ff
O
ff
1800
B
On
O
ff
1700
C
O
ff
On
1400
D
On
On
1225
A
O
ff
O
ff
1800
B
On
O
ff
1700
C
O
ff
On
1400
D
On
On
1225
DPHM36
DP5HM24
DP5HM30
DP5HM42
DP5HM48
DIP SWITCH FUNCTION SELECTION
Model
Default DIP Switch Setting
1
2
3
4
5
6
7
8
DP5HM2441
ON
OFF
OFF
OFF
ON
OFF
OFF
ON
DP5HM3041
ON
OFF
OFF
OFF
ON
OFF
OFF
OFF
DP5HM3641
ON
OFF
OFF
OFF
ON
OFF
ON
OFF
DP5HM4241
ON
ON
OFF
OFF
ON
ON
ON
OFF
DP5HM4841
OFF
OFF
OFF
OFF
OFF
OFF
OFF
ON