DM96SE*
PRESSURE SWITCH
GN
GR
D
OR
WARNING:DISCONNECT
N
TO
UNIT MUST BE
AND GROUNDED.
JU
N
C
T
ION
B
O
X
RD
L
S
ERVICING. W IRING
Ø /60 HZ
DISCONNECT
OVERCURRENT
GND
WH
115 VA
C/ 1
BK
POW ER BEFORE
TO
POW ER SUPPLY W ITH
PROTECTION DEVICE
PROPERLY POLARIZED
OUTPUT
NO
24 VAC POWER TO CONTROL
STA
NDBY NORMAL OPERATION
NO THERMOSTAT REQUESTS
OEM TEST MODE
CONTROL FAULT DETECTED
HAR
D LOCKOUT
ST
EADY ON
CONTINUOUS FAN OPERATION
CALL FOR COOLING
CALL FOR HEATING
CONTROL FUSE
OPEN
ID PLUG FAILURE
LOW FLAME SENSE
GAS VALVE CIRCUIT SHORTED
FLAM
E PRESENT WITH GAS
VALVE OFF
H
IGH LIMIT SWITCH OPEN
PS NULL ERROR :INCONSISTENT
READING WITH INDUCER OFF
PS NULL ERROR :INCONSISTENT
READING WITH INDUCER ON
SYSTEM LOCKOUT - RETRIES
EXCEEDED
7 FLASHES
5 FLASHES
4 FLASHES
3 FLASHES
2 FLASHES
1 FLASH
CLEAR ERROR HISTORY
FIELD TEST MODE
REVERSED LINE VOLTAGE
POLARITY
RAPID FLASH
OFF NO LED
ACTIVITY
L
ED ACTIVITY
AMBER
GREEN
RED
°C. USE COPPER CONDUCTORS ONLY.
SWITCH (TEMP.)
FIELD SPLICE
PLUG CONNECTION
PK PINK
5. UNIT MUST BE PERMANENTLY GROUNDED
A
ND CONFORM TO N.E.C. AND LOCAL CODES.
SWITCH (PRESS.)
TERMINAL
H
AVING A TEMPERATURE RATING OF AT LEAST 105
3. IF ANY OF THE ORIGINAL WIRE AS SUPPLIED
W
ITH THE FURNACE MUST BE REPLACED, IT
MUST BE REPLACED WITH WIRING MATERIAL
4. BLOWER SPEEDS SHOULD BE ADJUSTED BY
INSTALLER TO MATCH THE INSTALLATION
RE
QUIREMENTS SO AS TO PROVIDE
T
HE CORRECT HEATING TEMPRATURE
RISE AND THE CORRECT COOLING CFM.
IGNITER
PROT. DEVICE
OVERCURRENT
FIELD GND
EQUIPMENT GND
JUNCTION
INT
EGRATED CONTROL
INTERNAL TO
0140F02069-C
2. MANUFACTUR'S SPECIFIED REPLACEMENT
PARTS MUST BE USED WHEN SERVICING.
1. SET HEAT ANTICIPATOR ON ROOM THERMOSTAT AT
0
.7 AMPS.
NOTES:
H
I VOLTAGE FIELD
HI VOLTAGE (115V)
LOW VOLTAGE FIELD
LOW VOLTAGE (24V)
C
OLOR CODES:
RD RED
GY GRAY
BL B
LUE
WH WHITE
BR BROWN
B
K BLACK
GN GREEN
PU
PURPLE
OR ORANGE
YL YELLOW
W H
SE
N
S
O
R
YL
FL
A
M
E
GN
R
D
Y W R G
C
N.E.C. CLASS 2 WIRE
BK
DI
AGNOSTIC
LED'S
BR
GN
BK
PK
W H
BK
WH
WH
LIMIT CONTROL
AUXILIARY
AUTO RESET
GY
3
1
PRESSURE SW ITCH
I
D BLOW ER
BL
RD
W
H
B
R
WH
LI
MIT CONTRO L
AUTO RESET PRIMARY
W H
1
W
H
PU
B
K
P
RESSURE
TRANSDUCER
P
K
P
U
2
4
BK
G
ND
1
BLOWER
CIRCULATOR
B
K
GAS V
ALVE
C
ONNECTOR
2 CIRCUIT
YL
IGNITER
SURFACE
HOT
2
RD
2
BLOW ER
DRAFT
INDUCED
M
1
B
LOW ER COMPARTM ENT
HA
RNESS
ECM MTR
C2
RD
B
URNER COMPARTMENT
GND
FUS
E
3 A
24
V
PARK
PARK
COM
COOL
HEAT
GND
RD
9
8
12
1
11
7
4
10
K
BL
R
GY
GY
LINE
MOTOR XFMR HUM EAC FLAME
T2
2
T2
T1
T1
1
NEUTRAL
T9
T1
9
WH
40
VA
115
VAC
24
VAC
OR
TRANSFORMER
BLOWER
RD
COMPARTMENT
DOOR SWITCH
(OPEN WHEN
DOOR OPEN)
BK
BK
6 FLASHES
AUXILIARY LIMIT OPEN
G
N
6
3
5
2
2
3
4
1
BK
AUTO REST BURNER
TEMPERATURE
CONTROL
OR
GN
BL RD
3
1
2
RD
GN
BK
BK
4
OR
T1
0
T1
2
T4
T2
1
T3
BK
OR
RD
BL
BK
YL
RD
BK
WH
T20
T13
T8
T5
T7
T14
FAN
T2
3
G
ND
IDB(2)
HSI(1)
EAC-H
CLEANER
AIR
ELECTRONIC
FRONT COVER
PRESSURE
SWITCH
L
IN
E
NE
UT
RA
L
S
Ø /60 HZ POWER SUPPLY WITH
TO 115VAC/ 1
C2
GAS
VALVE
M1
MV(12)
HUMIDIFIER
R
Y
G
C
TO
MICRO
TR (11)
GND (8)
MVC (9)
RO2 (6)
RO1 (5)
GND
24 VA
C
40 VA
TRANSFORMER
115
VAC
FLAME SENSOR
ID
BLWR
CIRCULATOR
BLWR
HOT SURFACE
IGNITER
CO
OL
HE
AT
-H
FS
SWITCH
DOOR
OVERCURRENT PROTECTION DEVICE
N
L
DISCONNECT
GND
IN
T
E
G
R
A
T
E
D
C
O
NT
RO
L
M
O
D
U
L
E
FMR-H
LINE-H
JUNCTION BOX
INTEGRATED
CONTROL MODULE
TH (10 )
G
N
5
BR
BR
C
NO
PK
C
N
O
C
N
O
ID BLOWER
PRESSURE
SWITCH
PRESSURE
TRANSDUCER
PT (3)
PT
(
1)
PT (2)
+
-
O
AUTO RESET
AUXILIARY
LIMIT
CONTROLS
HLI (7)
HLO (4)
W
PK
PU
AUTO R ESET
BAFFLE LIMIT
2
1
2
1
3
C
NO
G
Y