20
APPENDIX B ELECTRICAL DATA
* Electric Heater kW rating: Rated at 240v for 208-230v units; 480v for 460v units
When using electric heat kit, use of the single point kit installed in the unit is required to meet UL requirements
UNIT
HEATER KIT
MODEL NUMBER
MINIMUM CFM
Downshot
HEATER KIT
MODEL NUMBER
MINIMUM CFM
Downshot
HEATER KIT
MODEL NUMBER
MINIMUM CFM
Downshot
EHK3-31
5250
EHK4-31
5250
EHK7-31
5250
15 TON
EHK3-46
5250
EHK4-46
5250
EHK7-46
5250
EHK3-60
5250
EHK4-60
5250
EHK7-60
5250
EHK3-31
7000
EHK4-31
7000
EHK7-31
7000
20 TON
EHK3-46
7000
EHK4-46
7000
EHK7-46
7000
25 TON
EHK3-60
7000
EHK4-60
7000
EHK7-60
7000
EHK3-75
7000
EHK4-75
7000
EHK7-75
7000
ATTENTION INSTALLING PERSONNEL
Use only the heater kit specified for each model as dictated by the table above.
RLA
LRA
RLA
LRA
QTY
HP
FLA
Type
HP
FLA
Part #
FLA
FLA
MCA
MOP
-
-
-
132 / 132
175 / 175
EHK3-31
21.6 / 28.8
60.0 / 69.3
-
132 / 132
175 / 175
EHK3-46
32.4 / 43.2
90.1 / 104
-
138 / 156
175 / 175
EHK3-60
43.3 / 57.6
120 / 139
-
176 / 165
200 / 175
EHK3-75
54.1 / 72.0
150 / 173
-
176 / 199
200 / 225
-
-
7.2 / 6.5
140 / 139
175 / 175
EHK3-31
21.6 / 28.8
60.0 / 69.3
7.2 / 6.5
140 / 139
175 / 175
EHK3-46
32.4 / 43.2
90.1 / 104
7.2 / 6.5
147 / 164
175 / 175
EHK3-60
43.3 / 57.6
120 / 139
7.2 / 6.5
185 / 173
200 / 175
EHK3-75
54.1 / 72.0
150 / 173
7.2 / 6.5
185 / 207
200 / 225
-
-
-
133 / 133
175 / 175
EHK3-31
21.6 / 28.8
60.0 / 69.3
-
133 / 133
175 / 175
EHK3-46
32.4 / 43.2
90.1 / 104
-
139 / 156
175 / 175
EHK3-60
43.3 / 57.6
120 / 139
-
176 / 165
200 / 175
EHK3-75
54.1 / 72.0
150 / 173
-
176 / 199
200 / 225
-
-
7.2 / 6.5
140 / 139
175 / 175
EHK3-31
21.6 / 28.8
60.0 / 69.3
7.2 / 6.5
140 / 139
175 / 175
EHK3-46
32.4 / 43.2
90.1 / 104
7.2 / 6.5
148 / 164
175 / 175
EHK3-60
43.3 / 57.6
120 / 139
7.2 / 6.5
185 / 173
200 / 175
EHK3-75
54.1 / 72.0
150 / 173
7.2 / 6.5
185 / 207
200 / 225
-
-
-
53.1
70
EHK4-31
34.6
-
55.0
70
EHK4-46
52.0
-
76.8
80
EHK4-60
69.3
-
81.1
90
EHK4-75
86.6
-
98.4
110
-
-
3.3
56.4
70
EHK4-31
34.6
3.3
59.1
70
EHK4-46
52.0
3.3
80.9
90
EHK4-60
69.3
3.3
85.2
90
EHK4-75
86.6
3.3
103
110
-
-
-
53.8
70
EHK4-31
34.6
-
55.9
70
EHK4-46
52.0
-
77.6
80
EHK4-60
69.3
-
81.9
90
EHK4-75
86.6
-
99.2
110
-
-
3.3
57.1
70
EHK4-31
34.6
3.3
60.0
70
EHK4-46
52.0
3.3
81.8
90
EHK4-60
69.3
3.3
86.1
90
EHK4-75
86.6
3.3
103
110
-
-
-
42.2
50
EHK7-31
28.9
-
45.5
50
EHK7-46
43.4
-
63.6
70
EHK7-60
57.8
-
67.2
80
EHK7-75
72.3
-
81.7
90
-
-
2.6
44.8
50
EHK7-31
28.9
2.6
48.8
50
EHK7-46
43.4
2.6
66.9
70
EHK7-60
57.8
2.6
70.4
80
EHK7-75
72.3
2.6
84.9
100
-
-
-
42.9
50
EHK7-31
28.9
-
46.4
50
EHK7-46
43.4
-
64.5
70
EHK7-60
57.8
-
68.1
80
EHK7-75
72.3
-
82.6
100
-
-
2.6
45.5
60
EHK7-31
28.9
2.6
49.6
60
EHK7-46
43.4
2.6
67.8
70
EHK7-60
57.8
2.6
71.3
80
EHK7-75
72.3
2.6
85.8
100
28.8
43.2
57.6
72.0
-
28.8
43.2
57.6
72.0
-
1
1.00
1.50
Std & High
Static -
Belt Drive
7.50
8.20
28.8
43.2
57.6
72.0
DCC300XXX7V
575-3-60
14.7
100.0
14.7
100.0
-
28.8
43.2
57.6
72.0
-
1
1.00
1.50
Std & High
Static -
Belt Drive
7.50
7.50
28.8
43.2
57.6
72.0
DCC300XXX7B
575-3-60
14.7
100.0
14.7
100.0
-
28.8
43.2
57.6
72.0
-
1
1.00
1.85
Standard -
Belt Drive
7.50
10.10
28.8
43.2
57.6
72.0
DCC300XXX4V
460-3-60
18.6
125.0
18.6
125.0
-
28.8
43.2
57.6
72.0
-
1
1.00
1.85
Std & High
Static -
Belt Drive
7.50
9.40
DCC300XXX4B
460-3-60
18.6
125.0
18.6
125.0
3.70
Std & High
Static -
Belt Drive
7.50
21.00
-
-
-
-
DCC300XXX3V
208/230-3-60
48.1
245.0
48.1
245.0
1
1.00
1
1.00
3.70
Std & High
Static -
Belt Drive
7.50
20.40
Optional Electric Heat
Optional Powered
Convienience Outlet
Power Supply
KW*
DCC300XXX3B
208/230-3-60
48.1
245.0
48.1
245.0
Model
Number
Electrical
Rating
Compressor
Circuit 1
Compressor
Circuit 2
Outdoor Fan Motor