Daikin DAFU-1000 Installation, Operation And Maintenance Manual Download Page 4

 Page 

4

 of 

1

5

DAFU-IOM—01

PURPOSE OF THIS MANUAL

The purpose of this manual is to allow the installer and the operator to carry out all operations and maintenance necessary to 

guarantee correct installation and maintenance of the machine without risking any damage to persons, animals, 

the 

environment and/

or property. 

THIS MANUAL IS AN ESSENTIAL GUIDE OF THE UNIT AND MUST BE KEPT FOR ITS ENTIRE LIFETIME.

All  personnel  appointed  to  run,  maintain,  or  supervise  the  unit  must  read  this  manual.  The  operator  appointed  to  carry  out 

maintenance  and  repairs  on  the  unit  or  to  regulate  the  same  must  be  a  skilled  person  with  adequate  and  recognized  professional 

qualifications for the relative operations.

MANUFACTURER DETAILS

Daikin 

guarantees that the AIR FILTRATION UNIT supplied

is complete and conforms to the Packing List.
is delivered together with Installation, Operation and Maintenance Manual

.

DAIKIN MIDDLE EAST & AFRICA FZE

P.O. BOX 18674

JEBEL ALI FREE ZONE DUBAI UAE  

     TEL: +971 4 8159 300

www.daikinmea.com

If the 

u

nit is not complete or does not conform to the 

p

acking

 l

ist, or if the manual is missing, please contact the Daikin sales network, quoting 

the specific data of the unit indicated on the name plate affixed to a wall of the unit. 

An e

xample of 

name plate is shown below:

Identification

AHU/AIR FILTRATION UNIT

MODEL

DAFU -1000

SERIAL NO.

DAME-2021-001

DATE

March-21

TECHNICAL DATA

NORMAL AIR FLOW

1000 CFM

MOTOR CAPACITY / FLA

500 W/ 2.22Amps

FAN RPM

1950 min

POWER SUPPLY (Volt / Phase / Hertz )

240~200V  1PH  60/50 HZ

START UP

Before start up

,

 carefully read 

the 

IOM check:

1) Fan Rotation

2) The current input must not exceed the values mentioned above

P.O. Box  18674  Jebel Ali Free Zone, Dubai, UAE 

MADE IN UAE

Summary of Contents for DAFU-1000

Page 1: ...Page 1 of 15 DAFU IOM 01 DAIKIN AIR FILTRATION UNIT INSTALLATION OPERATION AND MAINTENANCE MANUAL DAFU IOM 01 ORIGINAL INSTRUCTIONS...

Page 2: ...troduction Guidelines Qualifications Safety Warning Warranty Environmental Conditions Technical Features and Specifications Dimensional Drawing Wiring Diagram Routine Maintenance Non Routine Maintenan...

Page 3: ...e unloading of the unit Any damage or non conformity with the order must be written on the delivery note and a written complaint must be forwarded to Complaints or contestations sent later than 10 day...

Page 4: ...RATION UNIT supplied is complete and conforms to the Packing List is delivered together with Installation Operation and Maintenance Manual DAIKIN MIDDLE EAST AFRICA FZE P O BOX 18674 JEBEL ALI FREE ZO...

Page 5: ...he unit Lack of maintenance Unauthorised modifications or repairs Use of non original or unsuitable spare parts QUALIFICATION REQUIRED FOR THE USE AND MAINTENANCE OF THE UNIT GENERAL OPERATOR Authoris...

Page 6: ...Every operation on the system or on the electrical appliances must be carried out only by a Qualified Maintenance Electrician Always switch off voltage to the electrical panel before opening the elect...

Page 7: ...on the part of the operators failure to respect the installation use and maintenance instructions given in this manual or failure to comply with the safety rulings in force for the protection of the...

Page 8: ...outdoor air changes ACH The air filtration unit can be operated in any of the following modes 1 100 Exhaust 2 100 Recirculating This powerful unit is equipped with an EC Fan that has variable speed co...

Page 9: ...with activated carbon media Minimum efficiency reporting value MERV 7 UL Classified UV Lamp High output UV lamp 254 nm to inactivate virus bacteria and fungi AstroCel III HEPA filters H14 HEPA Filters...

Page 10: ...Page 10 of 15 DAFU IOM 01 DIMENSIONAL DRAWING ELECTRICAL WIRING...

Page 11: ...not running and spinning Check for any damaged or broken cables Ensure that casters are locked properly and tightly Figure 3 If the HEPA filter is clogged then the red light will switch on meaning th...

Page 12: ...a frame to avoid damage MERV8 PRE Filter Usually the pre filter is installed in the lower position and is recommended to be changed every 2 3 months or as required for better performance For checking...

Page 13: ...move upward and filter can be easily slide out Figure 7 6 5 Examine the filter frame and filter cabin for any contamination moisture or any dust particles Clean with dry cloth 6 Slide out the contami...

Page 14: ...s panel properly Check Non Routine Maintenance Section Unusual Sound and Unit Vibration Check if the filters are clogged and replace it if necessary Check Non Routine Maintenance section Dirty Filter...

Page 15: ...Page 15 of 15 DAFU IOM 01 Africa P O Box 18674 Plot MO0426 JAFZA North Jebel Ali Free Zone Dubai UAE Tel 971 0 4 815 9300 Fax 971 0 4 815 9311 Toll Free 800 DAIKIN 324546 www daikinmea com...

Reviews: