background image

3 Operation

Operation manual

8

D2CND024A1/4AB + D2TND012~024A4AB

Wall-mounted condensing boiler

3P469438-3M – 2019.11

NOTICE

A  table  with  all  error  codes,  the  reasons  for  their
appearance,  and  possible  solutions,  is  located  at  the  very
end of this manual.

3.5

Menu functions

3.5.1

To use menu level 1

1

Press the "Menu" button while you are at home screen to go the
Menu screen. This is menu level 1 screen.

2

To switch between info, user settings and service settings, turn
the left dial.

3

To leave the menu and return to the home screen, press "Back"
for 2 seconds.

When there is no user interaction for one minute, the user interface
will leave the menu and switch to the blank screen.

3.5.2

Info menu

Info menu: Parameters

The  info  menu  ( )  covers  all  possible  information  that  is  made
available  to  the  end  user  and  to  the  installer.  This  parameters  are
read only and cannot be changed.

#

Description (short)

Unit

A00

Actual flow temperature

°C

A01

Actual return temperature

°C

A02

Actual domestic hot water temperature

°C

A03

Actual flue temperature

°C

A04

(a)

Actual outdoor temperature

°C

A05

(a)

Actual solar temperature

°C

A06

Actual water pressure

bar

A07

Actual domestic hot water flow rate

l/min

A08

(b)

Current set point of burner capacity

%

A09

(b)

Actual capacity of boiler in relation to
nominal capacity

%

A10

(c)

Actual phase of the burner

A11

Status of On-Off room thermostat,
indicate heat demand (HC1)

A12

Actual error code of boiler

A13

Actual fan speed (rpm/100)

rpm

A14

Current setpoint of boiler pump

%

F11

(d)

Fuel energy consumption / Central
Heating / Last month

kWh

#

Description (short)

Unit

F12

(d)

Fuel energy consumption / Central
Heating / Current month

kWh

F13

(d)

Fuel energy consumption / Central
Heating / Current Year

kWh

F21

(d)

Electric energy consumption / Central
Heating / Last month

kWh

F22

(d)

Electric energy consumption / Central
Heating / Current month

kWh

F23

(d)

Electric energy consumption / Central
Heating / Current Year

kWh

F31

(d)

Fuel energy consumption / Domestic hot
water / Last month

kWh

F32

(d)

Fuel energy consumption / Domestic hot
water / Current month

kWh

F33

(d)

Fuel energy consumption / Domestic hot
water / Current Year

kWh

F41

(d)

Electric energy consumption / Domestic
hot water / Last month

kWh

F42

(d)

Electric energy consumption / Domestic
hot water / Current month

kWh

F43

(d)

Electric energy consumption / Domestic
hot water / Current Year

kWh

(a)

Not applicable if the sensor is not connected.

(b)

Maximum value for central heating = 91%
Maximum value for domestic hot water = 100%

(c)

A10=0: Standby mode, burner is not active
A10=1: Start-up, preparation to ignition
A10=2: Ignition and flame stabilisation phase
A10=3: Release control (burner is on, operation phase)
A10=4: Post-purge phase

(d)

Applicable if energy metering is enabled. Consumed
energy values are shown with 6 digits. The display
sequence is: parameter ID – first 3 digits – last 3 digits.
E.g. if 3456 kWh central heating fuel energy consumed in
current month, following screens are displayed in a
sequence of; F12 – 003 - 456

To use the info menu

1

Press  the  "Enter"  button  when  the 

  icon  is  displayed  on  the

menu level 1 screen.

2

Select A or F parameters with the left dial.

3

Select  the  index  number  with  the  right  dial.  Press  the  "Back"
button to return to menu level 1 screen.

a

a

a

Index

Summary of Contents for D2CND024A1AB

Page 1: ...Operation manual Wall mounted condensing boiler English Operation manual Wall mounted condensing boiler D2CND024A1AB D2CND024A4AB D2TND012A4AB D2TND018A4AB D2TND024A4AB ...

Page 2: ...ndensing boiler that can supply heat to central heating systems as well as supply domestic hot water Depending on settings it is possible to use the unit solely for hot water or solely for central heating Hot water supply type can be instantaneous or by means of a hot water storage tank Heating only boilers do not supply domestic hot water The type of the boiler can be recognised from the model na...

Page 3: ...ever attempt to perform maintenance or repair yourself Call a qualified service agent CAUTION Do not use sprays solvents chlorinated cleaning agents paint and adhesives in the vicinity of the unit These substances can cause corrosion even in the flue system DANGER Do not damage or remove any seals on components Only qualified persons are allowed to alter sealed components Do not make any modificat...

Page 4: ...show the home screen of the active operation mode and the related setpoint depending on the system configuration see 3 3 3 Possible operation modes 45 Status icons Meaning of icons that appear on the LCD screen Icon Description Operation mode Standby mode Domestic hot water operation enabled Domestic hot water comfort mode is enabled Central heating operation enabled Room temperature Outdoor senso...

Page 5: ...mode c Summer mode d Winter mode e Full off mode 3 3 3 Possible operation modes Operation mode Description Central heating only mode Only central heating operation mode is enabled The central heating temperature setpoint which setpoint is shown depends on the system configuration see 3 3 5 Possible central heating operation modes 4 6 and the icon is shown on the home screen The icon blinks if cent...

Page 6: ...oom temperature is displayed The room temperature setpoint can be adjusted from the user interface by means of the left dial or from the Daikin room thermostat The icon is shown on the screen instead of the icon when central heating operation mode is enabled Boiler outdoor sensor Weather compensation The case that outdoor sensor is connected to the boiler In this case the central heating water tem...

Page 7: ...ion the unit must be connected to the power supply and its main gas valve must be open Any damage caused by frost is not covered by the warranty Frost Protection is enabled in all modes including standby mode and full off mode While frost protection is active Fr and actual flow temperature are displayed subsequently on the display WARNING If the boiler is not connected to the power supply frost pr...

Page 8: ...l energy consumption Central Heating Last month kWh Description short Unit F12 d Fuel energy consumption Central Heating Current month kWh F13 d Fuel energy consumption Central Heating Current Year kWh F21 d Electric energy consumption Central Heating Last month kWh F22 d Electric energy consumption Central Heating Current month kWh F23 d Electric energy consumption Central Heating Current Year kW...

Page 9: ...value same function that can be done via the right dial when domestic hot water mode is enabled U05 When On Off room thermostat and outdoor sensor are both connected this parameter value is the virtual room temperature setpoint when there is a heat demand U06 When On Off room thermostat and outdoor sensor are both connected this parameter value is the virtual room temperature setpoint when there i...

Page 10: ...Do not let your room become too hot Decreasing the room temperature during the day saves energy Have your combi boiler s maintenance performed at least annually Provide your building with sufficient heat insulation Thermostatic valves should be used Each room should be adjusted according to comfort conditions For reception rooms this is 20 C living rooms 22 C kitchens 18 C and bedrooms 18 C Preven...

Page 11: ...E1 73 Internal PCB error Perform reset if needed If problem repeats contact your service agent H9 01 Outside sensor fault Boiler continues operation but outside sensor is defective Contact your service agent HC 01 Domestic hot water temperature sensor fault Boiler continues operation but you must contact your service agent HJ 08 High system pressure Discharge water down to 0 8 bar You can bleed th...

Page 12: ...who commissioned the boiler as a means of demonstrating compliance with the appropriate Building Regulations and then handed to the customer to keep for future reference GAS BOILER SYSTEM COMMISSIONING CHECKLIST CONTROLS Programmable room thermostat Optimum start control Combination Boiler Fitted Fitted Fitted Automatic bypass to system Fitted Boiler interlock ALL SYSTEMS Yes Yes CENTRAL HEATING M...

Page 13: ...It is recommended that your heating system is serviced regularly and that the appropriate Service Interval Record is completed Service Provider SERVICE RECORD SERVICE 01 AND Where Possible AND Signature SERVICE 02 AND Where Possible AND Signature SERVICE 03 AND Where Possible AND Signature SERVICE 04 AND Where Possible AND Signature SERVICE 05 AND Where Possible AND Signature SERVICE 06 AND Where ...

Page 14: ......

Page 15: ......

Page 16: ...STANBUL TÜRKİYE Tel 0216 453 27 00 Faks 0216 671 06 00 Çağrı Merkezi 444 999 0 Web www daikin com tr Gülsuyu Mahallesi Fevzi Çakmak Caddesi Burçak Sokak No 20 34848 Maltepe 3P469438 3M 2019 11 Copyright 2018 Daikin Verantwortung für Energie und Umwelt ...

Reviews: