3 Operation

Operation manual

5

D2CND024A1/4AB + D2TND012~024A4AB
Wall-mounted condensing boiler
3P469438-3M – 2019.11

When  this  function  is  active,  boiler  operates  according  to  a  defined
set  value  for  around  15  minutes  and  the 

  icon  blinks.  After  this

function is ended, normal operation goes on.

INFORMATION

Low  water  temperature  function  is  a  safety  function  and  it
cannot be disabled.

3.2.3

About the electronic gas adaptive system
calibration

The  electronic  gas  adaptive  system  calibrates  itself  in  pre-
determined  intervals.  First  calibration  takes  place  just  after  first
burner activation after each power ON. Calibration process duration
is  around  60  seconds  and  the 

  icon  blinks.  After  calibration  is

ended,  boiler  modulates  to  required  capacity.  Calibration  process
has no effect on boiler operation.

Calibration  can  also  take  place  in  summer  mode  without  water
tapping  if  proper  conditions  are  met.  In  other  words,  boiler  may
operate itself for a short duration in summer mode even though there
is no domestic hot water demand. This is an expected behavior.

3.3

Basic usage

3.3.1

About the home screen

It is the screen that is displayed after activating the LCD screen with
one of the dials or buttons. You can use the home screen to read out
settings that are meant for daily use. What you can see on the home
screen depends on your system configuration.

The following home screens may be possible:

▪ Room temperature (Daikin room thermostat connected)

▪ Central heating set temperature

▪ Virtual room temperature (with outdoor sensor)

▪ Domestic hot water set temperature

▪ System pressure (at standby mode)

3.3.2

To select the operation mode

The operation mode can be changed by pressing the "Mode" button
(

).

(5 s)

(5 s)

a

c

b

d

e

a

Central heating only mode

b

Standby mode

c

Summer mode

d

Winter mode

e

Full-off mode

3.3.3

Possible operation modes

Operation mode

Description

Central heating only mode

▪ Only central heating operation mode

is enabled.

▪ The  central  heating  temperature

setpoint  (which  setpoint  is  shown
depends 

on 

the 

system

configuration;  see 

"3.3.5  Possible

central 

heating 

operation

modes"

  [

4

  6])  and  the 

  icon  is

shown on the home screen.

▪ The    icon  blinks  if  central  heating

operation is active.

Standby mode

▪ Both  central  heating  and  domestic

hot  water  operation  modes  are
disabled.

▪ The  protection  functions  such  as

frost  protection  are  still  active  at
standby mode.

▪ The home screen shows the system

pressure, as well as the   icon.

Summer mode

▪ Only  domestic  hot  water  operation

mode  is  enabled.  Central  heating
operation  mode  is  disabled.  The
boiler  will  only  produce  heat  for
domestic hot water.

▪ The  domestic  hot  water  setpoint,

and  the 

  icon  is  shown  on  the

home screen.

▪ The 

  icon  blinks  if  domestic  hot

water operation is active.

Winter mode

▪ Both  domestic  hot  water  operation

mode  and  central  heating  operation
mode  are  enabled.  The  boiler  can
produce domestic hot water, as well
as produce heat for central heating.

▪ The  central  heating  temperature

setpoint  (which  setpoint  is  shown
depends 

on 

the 

system

configuration;  see 

"3.3.5  Possible

central 

heating 

operation

modes"

  [

4

  6]),  and  the 

  icon,  as

well as the   icon are shown on the
home  screen.  When  domestic  hot
water  operation  is  active,  domestic
hot  water  setpoint  is  shown  on  the
home screen.

▪ The 

  icon  blinks  if  domestic  hot

water operation is active.

▪ The    icon  blinks  if  central  heating

operation is active.

Full-off mode

▪ Both  central  heating  and  domestic

hot  water  operation  modes  are
disabled.

▪ LCD  display  will  be  darkened  and

will  not  be  activated  with  any  user
interaction.

▪ The  protection  functions  such  as

frost protection are still active at full-
off mode.

▪ Full-off  mode  is  activated  and

deactivated  if  "Mode"  button  is
pressed for 5 seconds while boiler is
in any mode.

Summary of Contents for D2CND-A1A

Page 1: ...Operation manual Wall mounted condensing boiler English Operation manual Wall mounted condensing boiler D2CND024A1AB D2CND024A4AB D2TND012A4AB D2TND018A4AB D2TND024A4AB ...

Page 2: ...ndensing boiler that can supply heat to central heating systems as well as supply domestic hot water Depending on settings it is possible to use the unit solely for hot water or solely for central heating Hot water supply type can be instantaneous or by means of a hot water storage tank Heating only boilers do not supply domestic hot water The type of the boiler can be recognised from the model na...

Page 3: ...ever attempt to perform maintenance or repair yourself Call a qualified service agent CAUTION Do not use sprays solvents chlorinated cleaning agents paint and adhesives in the vicinity of the unit These substances can cause corrosion even in the flue system DANGER Do not damage or remove any seals on components Only qualified persons are allowed to alter sealed components Do not make any modificat...

Page 4: ...show the home screen of the active operation mode and the related setpoint depending on the system configuration see 3 3 3 Possible operation modes 45 Status icons Meaning of icons that appear on the LCD screen Icon Description Operation mode Standby mode Domestic hot water operation enabled Domestic hot water comfort mode is enabled Central heating operation enabled Room temperature Outdoor senso...

Page 5: ...mode c Summer mode d Winter mode e Full off mode 3 3 3 Possible operation modes Operation mode Description Central heating only mode Only central heating operation mode is enabled The central heating temperature setpoint which setpoint is shown depends on the system configuration see 3 3 5 Possible central heating operation modes 4 6 and the icon is shown on the home screen The icon blinks if cent...

Page 6: ...oom temperature is displayed The room temperature setpoint can be adjusted from the user interface by means of the left dial or from the Daikin room thermostat The icon is shown on the screen instead of the icon when central heating operation mode is enabled Boiler outdoor sensor Weather compensation The case that outdoor sensor is connected to the boiler In this case the central heating water tem...

Page 7: ...ion the unit must be connected to the power supply and its main gas valve must be open Any damage caused by frost is not covered by the warranty Frost Protection is enabled in all modes including standby mode and full off mode While frost protection is active Fr and actual flow temperature are displayed subsequently on the display WARNING If the boiler is not connected to the power supply frost pr...

Page 8: ...l energy consumption Central Heating Last month kWh Description short Unit F12 d Fuel energy consumption Central Heating Current month kWh F13 d Fuel energy consumption Central Heating Current Year kWh F21 d Electric energy consumption Central Heating Last month kWh F22 d Electric energy consumption Central Heating Current month kWh F23 d Electric energy consumption Central Heating Current Year kW...

Page 9: ...value same function that can be done via the right dial when domestic hot water mode is enabled U05 When On Off room thermostat and outdoor sensor are both connected this parameter value is the virtual room temperature setpoint when there is a heat demand U06 When On Off room thermostat and outdoor sensor are both connected this parameter value is the virtual room temperature setpoint when there i...

Page 10: ...Do not let your room become too hot Decreasing the room temperature during the day saves energy Have your combi boiler s maintenance performed at least annually Provide your building with sufficient heat insulation Thermostatic valves should be used Each room should be adjusted according to comfort conditions For reception rooms this is 20 C living rooms 22 C kitchens 18 C and bedrooms 18 C Preven...

Page 11: ...E1 73 Internal PCB error Perform reset if needed If problem repeats contact your service agent H9 01 Outside sensor fault Boiler continues operation but outside sensor is defective Contact your service agent HC 01 Domestic hot water temperature sensor fault Boiler continues operation but you must contact your service agent HJ 08 High system pressure Discharge water down to 0 8 bar You can bleed th...

Page 12: ...who commissioned the boiler as a means of demonstrating compliance with the appropriate Building Regulations and then handed to the customer to keep for future reference GAS BOILER SYSTEM COMMISSIONING CHECKLIST CONTROLS Programmable room thermostat Optimum start control Combination Boiler Fitted Fitted Fitted Automatic bypass to system Fitted Boiler interlock ALL SYSTEMS Yes Yes CENTRAL HEATING M...

Page 13: ...It is recommended that your heating system is serviced regularly and that the appropriate Service Interval Record is completed Service Provider SERVICE RECORD SERVICE 01 AND Where Possible AND Signature SERVICE 02 AND Where Possible AND Signature SERVICE 03 AND Where Possible AND Signature SERVICE 04 AND Where Possible AND Signature SERVICE 05 AND Where Possible AND Signature SERVICE 06 AND Where ...