6
|
Unit installation
Installer reference guide
25
FTXA25~50(A)(B)2V1B(W)(S)(T)(B)
Daikin room air conditioner
4P518023-3K – 2022.05
a
Arm
b
Shaft
c
Shaft slot
4
Disconnect the front panel shaft from the shaft slot on the left side.
a
c
b
a
Arm
b
Shaft slot
c
Shaft
5
Remove the front panel.
6
To re-install the front panel perform the steps in the opposite order.
6.2.3 To open the service cover
1
Remove 1 screw from the service cover.
2
Pull out the service cover horizontally away from the unit.
a
b
a
Service cover screw
b
Service cover
NOTICE
When closing the service cover, make sure that the tightening torque does NOT
exceed 1.4 (±0.2) N•m.
6.2.4 To remove the front grille
CAUTION
Wear adequate personal protective equipment (protective gloves, safety glasses,…)
when installing, maintaining or servicing the system.
1
Open the front panel. Refer to
"6.2.1 To open the front panel"
24].
2
Remove the service cover. Refer to
"6.2.3 To open the service cover"
25].
3
Remove the wire harness from the wire clamp and the connector.
4
Remove the flap by pushing it to the left side and towards you.
5
Remove the 2 screw covers using a long flat plate such as a ruler wrapped in a
cloth and remove 2 screws.