Electrical Box
Si041351ED
6
Removal Procedure
3. Electrical Box
Warning
Be sure to wait for 10 minutes or more after turning off all power supplies before
disassembling work.
Step
Procedure
Points
1
2
Remove the screw.
Remove the drip proof
plate from the indoor
heat exchanger.
The shape of the drip proof
plate varies by the model.
When reassembling, fit the
hook to the indoor heat
exchanger.
3
Cut the clamp.
4
Pull out and release the
earth / ground wire.
(R16273)
(R18724)
Drip proof plate
(R16274)
(R19306)
Earth / ground wire