Display
5
Names of Parts
Indoor Unit
Air inlet
Upper front
panel
Air outlet
Louvres (vertical blades)
•
The louvres are inside of the air outlet.
Page 13
INTELLIGENT EYE
sensor
•
Detects the movements of
people and automatically
switches between normal
operation and energy saving
operation.
Page 15-17
Flaps
(horizontal
blades)
Page 13
INTELLIGENT EYE lamp
(green)
Page 16
Signal receiver and Indoor
unit ON/OFF switch
Signal receiver
•
Receives signals from the remote
controller.
• When the unit receives a signal, you will
hear a beep sound.
Case
Sound type
Operation start
beep-beep
Setting changed
beep
Operation stop
long beep
Indoor unit ON/OFF switch
•
Press this switch once to start operation.
Press once again to stop it.
• For the operation mode setting, refer to the following
table.
Model
Mode
Temperature
setting
Airfl ow
rate
HEAT PUMP
AUTO
25.0°C
AUTO
COOLING ONLY
COOL
22.0°C
AUTO
•
This switch can be used when the remote controller is
missing.
TIMER lamp
• When operation by timer has been set, the multi-monitor lamp
periodically changes to orange. After lighting orange for about
5 seconds, it returns to the colour of the operation mode.
The multi-monitor lamp will turn orange on and off in cyclic
manner while the air conditioner is not in operation.
TIMER lamp colour
TIMER lamp colour: For COOL
Orange
Blue
3 min.
5 sec.
5 sec.
2 sec.
2 sec.
2 sec.
Green
Orange
DRY:
COOL: Blue
Orange
HEAT: Red
Orange
FAN:
White
Orange
Stop:
Off
Orange
Indoor temperature
sensor
•
Detects the air temperature
around the unit.
Multi-monitor lamp and
TIMER lamp
Multi-monitor lamp
•
The lamp colour changes according to
the operation.
Operation
Multi-monitor lamp
AUTO*
Red/Blue
DRY
Green
COOL
Blue
HEAT*
Red
FAN
White
TIMER
Orange
* Only for HEAT PUMP models
Lower front panel
•
It is located on the back of the
upper front panel during operation.
01_EN_3P472684-1.indd 5
6/13/2017 9:01:24 AM
Summary of Contents for CTKJ25RVMAS
Page 43: ...Memo 42 ...