![background image](http://html1.mh-extra.com/html/daikin/ctkc15qvm4/ctkc15qvm4_removal-procedure_4699271013.webp)
Si041551EB
PCBs
Removal Procedure
11
4
Unfasten the 3 hooks
and remove the
INTELLIGENT EYE
sensor PCB.
3. Remove the display/
signal receiver PCB.
1
Release the harness
from the slit and the 3
hooks.
2
Turn over the PCB
ASSY, unfasten the 3
hooks and remove the
display/signal receiver
PCB.
Step
Procedure
Points
Hook
Hook
INTELLIGENT EYE sensor PCB
(R24248)
Hook
Slit
(R22079)
Hook
Hook
Back view
Display/signal
receiver PCB