background image

4

(Adjustable 
angle)

45

°

Press the signal 
receiver into the 
insulated mounting 
frame.

1

Press the signal receiver 
and mounting frame into 
the faceplate frame and 
secure with two screws.

2

Mount the 
completed 
assembly using 
two screws.

3

Press the 
faceplate onto 
the faceplate 
frame.

4

Press the 
decorative 
cover into the 
faceplate.

5

Nut (commercially available)

Washer (commercially available)

Tighten 
(two nuts)

;

;;;

;;;

;;

;

;;

;;

;;

;

;

Vinyl tube

Water level

INDOOR UNIT INSTALLATION

Temporarily install the indoor unit.

Attach the hanger brackets to the suspension bolts. Be
sure to use nuts and washers both above and below
the hanger brackets to secure them.

NOTE) Use washers when mounting with M8 bolts.

Use a water level or water-filled vinyl tubes to
check that the unit is level at all four corners as
shown in the drawing.

Tighten the top nuts.

Mounting the signal receiver

Mount the signal receiver as shown below.

Note)

Mount the remote control cord far enough away from strong electrical wires (such as distribution wires for electrical
lights, air conditioners, etc.) and from weak electrical wires (such as wires for telephones, intercoms, etc.).

For heat pump:

If your feet feel cold when using the heating
function, it is recommended that the air
discharge grill shown at right be attached.

OUTDOOR UNIT INSTALLATION

Install as described in the installation manual supplied with the Multi outdoor unit.

Summary of Contents for CDXS25BVMB

Page 1: ...plit R 410A Fran ais Manuel d installation S rie split R 410A Italiano Manuale d installazione Serie Multiambienti R 410A Nederlands Montagehandleiding R 410A Split systeem Portugues Manual de Instala...

Page 2: ...eceive no external stresses Incomplete connections or clamping may cause terminal overheating or fire After connecting interconnecting and supply wiring be sure to shape the cables so that they do not...

Page 3: ...gh to support the weight of the unit If there is a risk that the ceiling is not strong enough reinforce the ceiling before installing the unit Select the signal receiver mounting location within the s...

Page 4: ...he suspension bolt positions Install the suspension bolts Use M10 size bolts for the suspension bolts In order to reinforce the ceiling bearing the weight of the unit use anchors when installing onto...

Page 5: ...nd below the hanger brackets to secure them NOTE Use washers when mounting with M8 bolts Use a water level or water filled vinyl tubes to check that the unit is level at all four corners as shown in t...

Page 6: ...g into the system as this would reduce the lifetime of the units Never use piping which has been used for previous installations Only use parts which are delivered with the unit Do never install a dri...

Page 7: ...fittings observe the following Insulation material Polyethylene foam Heat transfer rate 0 041 to 0 052kW mK 0 035 to 0 045 kcal mh C Refrigerant gas pipe s surface temperature reaches 110 C max Choos...

Page 8: ...y screw wires to the corresponding terminals 3 Connect the earth wires to the corresponding terminals 4 Pull wires to make sure that they are securely latched up then retain wires with wire retainer 5...

Page 9: ...e of the unit and push the other side gently over the 2 bends Cleaning the drain pan Clean the drain pan periodically or drain piping may be clogged with dust and may result in water leakage Ask your...

Page 10: ...power in its standby mode If the system is not to be used for some time after installation shut off the circuit breaker to eliminate unnecessary power consumption If the circuit breaker trips to shut...

Page 11: ...2P098794 3 M02B075 0210 HT...