Troubleshooting
SiBE07-618_C
60
Service Diagnosis
4. Troubleshooting
4.1
Error Codes and Description
★
: Displayed only when system-down occurs.
Error Codes
Description
Reference
Page
System
00
Normal
—
U0
★
Refrigerant shortage
90
U2
Low-voltage detection or over-voltage detection
92
U4
Signal transmission error (between indoor unit and outdoor unit)
66
UA
Unspecified voltage (between indoor unit and outdoor unit)
67
Indoor
Unit
A1
Indoor unit PCB abnormality
61
A5
Freeze-up protection control or heating peak-cut control
62
A6
Fan motor (AC motor) or related abnormality
64
C4
Indoor heat exchanger thermistor or related abnormality
65
C9
Room temperature thermistor or related abnormality
65
Outdoor
Unit
E1
Outdoor unit PCB abnormality
68
E5
★
OL activation (compressor overload)
69
E6
★
Compressor lock
70
E7
DC fan lock
71
E8
Input overcurrent detection
72
EA
Four way valve abnormality
73
F3
Discharge pipe temperature control
75
F6
High pressure control in cooling
76
H0
Compressor system sensor abnormality
77
H6
Position sensor abnormality
78
H8
CT or related abnormality
80
H9
Outdoor temperature thermistor or related abnormality
82
J3
Discharge pipe thermistor or related abnormality
82
J6
Outdoor heat exchanger thermistor or related abnormality
82
L3
Electrical box temperature rise
84
L4
Radiation fin temperature rise
86
L5
Output overcurrent detection
88
P4
Radiation fin thermistor or related abnormality
82
U7
Signal transmission error (on outdoor unit PCB)
93