Dust Collection with Vacuum Cleaner

Vacuum the dust in the dust box on completion of confirming the dust collection sign.

NOTE

• 

Dust collection with a vacuum cleaner is not possible during filter auto cleaning. Make sure that " 

 " 

is not displayed on the remote controller screen before dust collection. 

* The indicator will flash green if the indicator is set to display. (See page 5).

Connect the provided connection pipe and attachment to match the vacuum cleaner 

pipe. 

Insert the connection pipe and attachment into the vacuum cleaner pipe.

Vacuum cleaner pipe

Vacuum cleaner pipe

Connection pipe

Connection pipe

Attachment

Vacuum cleaner pipe with an inner diameter 

of 32 to 38 mm in diameter.

Vacuum cleaner pipe with an inner diameter 

of 38 to 42 mm in diameter.

When storing the connection pipe, use the provided hook-and-loop fastener strip and take the following procedure.

Example 1

1.  Peel the release paper off the double-stick tape on 

the back of the fastener strip, and paste the 

fastener strip onto a flat surface in the place of 

storage.

2.  Press the fastener strip of the connection pipe 

onto the fastener strip pasted in step 1.

Flat surface in the 

place of storage

Connection pipe

Hook-and-loop 

fastener strips

Example 2

Wind the hook-and-loop fasteners on the connection 

pipe around a vacuum cleaner hose or pipe to store 

the connection pipe.

Connection pipe

Vacuum cleaner 

hose or pipe

Hook-and-loop 

fastener strips

NOTE

•  The attachment cannot be connected to a vacuum cleaner pipe without a round-shaped leading end 

(e.g., a stand-type or handheld-type vacuum cleaner) or a pipe that has a hole midway to cause air 

leakage. Consult your Daikin dealer if the attachment cannot be connected to your vacuum cleaner.

• 

Use a vacuum cleaner with a minimum sucking work rate of 300 W.

•  Do not use a vacuum cleaner full of dust and low in suction power. 

* The use of the above vacuum cleaner may result in a dust collection failure.

Summary of Contents for BYCQ140E2GW1

Page 1: ...g the use of the product Read this manual carefully and be sure you understand the information provided before attempting to use the product Keep this manual where it is readily accessible after readi...

Page 2: ...140E2GW1 BYCQ140E2GFW1 BYCQ140E2GFW1B Self cleaning decoration panel 4P558846 1A 2018 12 1 Contents Safety Precautions 2 Names and Functions 5 Filter Auto Cleaning 8 Dust Collection from Dust Box 13 U...

Page 3: ...er is not operating correctly i e not generating cool or warm air refrigerant leakage could be the cause Consult your dealer for assistance The refrigerant within the air conditioner is safe and norma...

Page 4: ...is may result in fire Before cleaning be sure to stop unit operation turn the breaker off or remove the power cord Otherwise an electric shock and injury may result To avoid electric shocks do not ope...

Page 5: ...t Leaves are a hotbed for small animals which can enter the unit Once in the unit such animals can cause malfunctions smoke or fire when making contact with electrical parts Never touch the internal p...

Page 6: ...in air conditioning operation Flashing The product is performing filter auto cleaning Red Flashing at long intervals Time to collect the dust in the dust box with the dust detected by the dust sensor...

Page 7: ...tem selected 5 Down button Be sure to press the part with the symbol Used to lower the set temperature The next items on the lower side will be highlighted The highlighted items will be scrolled conti...

Page 8: ...ollers will not be lit simultaneously 1 Filter auto cleaning display Displayed while the product is performing filter auto cleaning 2 Message The following message will appear Error Push Menu Button W...

Page 9: ...while the product is performing filter auto cleaning Specify the desired period from eight periods NOTE The correct clock settings are necessary The product will perform filter auto cleaning from 00 0...

Page 10: ...t hour or when cooling or heating demand is rather low during the third hour the unit forces execution of the cleaning function even when the unit is operating After completion of the cleaning functio...

Page 11: ...set for some reason e g no power is supplied to the product for 48 hours or longer The product may generate a little noise when the filter rotates or the dust is scraped with the brush The fan rotates...

Page 12: ...07 Thursday 12 00 Return Setting Select Hour with buttons Input the hour with buttons Holding down the button causes the number to change continuously 8 Date Time Year 2011 Month 10 Day 07 Thursday 1...

Page 13: ...tilation mode Auto Schedule Disable Display Mode Standard Display Item Outside Filter auto clean 00 03 A list showing the current setting status will appear Press buttons to go to the next item Pressi...

Page 14: ...splay Collection sign 1 Collection sign 2 Collection sign 3 Collection sign 4 Remote controller LCD The messages Collect dust and Press Menu Button will appear alternately AH error sign will appear Op...

Page 15: ...vided hook and loop fastener strip and take the following procedure Example 1 1 Peel the release paper off the double stick tape on the back of the fastener strip and paste the fastener strip onto a f...

Page 16: ...let Connection pipe Rises approximately 10 mm Internal cross section of dust collection inlet Air inlet 4 While the leading end of the connection pipe closely come in contact turn on the vacuum cleane...

Page 17: ...Method An illustration of vacuuming dust from the dust collection inlet will appear See Dust Collection with Vacuum Cleaner on page 14 After understanding the method of dust collection press the Menu...

Page 18: ...indicator to flash green Check before requesting servicing Symptom Probable cause Remedy Dust sticks to the air filter dust falls The room has a large quantity of dust temporarily as a result of the c...

Page 19: ...troller Error Push Menu Button The operation indicator will blink Warning Push Menu Button The operation indicator will not blink Check the malfunction codes See below Error code Display Operation Met...

Page 20: ...Your address name and telephone number Repairs after Expiration of Cost free Guarantee Repair Period Contact your Daikin dealer Daikin will conduct paid repairs if the product is repairable with its...

Page 21: ...ction cost Furthermore the inspection and maintenance frequencies may be shorter than those specified in the table depending on the content of the maintenance inspection contract 3 The product require...

Page 22: ...58846 1A 2018 12 21 Relocation Contact your Daikin dealer because the same requires a specialized technique in the case of relocating and reinstalling the air conditioner for some reason e g the movem...

Page 23: ......

Page 24: ...Copyright 2018 Daikin 4P558846 1A 2018 12...

Reviews: