background image

4 Preparation

Installer reference guide

4

BRBRP069A62

Daikin Altherma LAN adapter

4P464229-1A – 2017.11

Accessories: BRP069A61

a

b

c

d

f

e

f

g

h

i

j

k

a

Installation manual

b

6-pole slide connector for X1A

c

2-pole slide connector for X2A

d

2-pole plug connector for X3A

e

Ethernet cable

f

Grommets

g

Screws to mount rear casing

h

Plugs to mount rear casing

i

Screws to mount PCB

j

Screw to close front casing

k

Cable tie

Accessories: BRP069A62

a

b

c

d

e

f

g

h

a

Installation manual

b

2-pole plug connector for X3A

c

Ethernet cable

d

Grommet

e

Screws to mount rear casing

f

Plugs to mount rear casing

g

Screws to mount PCB

h

Screw to close front casing

4

Preparation

4.1

Installation site requirements

INFORMATION

Also read the maximum cable length requirements set out
in 

"4.2 Overview of electrical connections" on page 4

.

▪ Mind the following spacing installation guidelines:

>30 mm

>30 mm

>90 mm

(a)

>160 mm

(b)

(a)

Provide enough space to connect the Ethernet cable
without exceeding its minimum bend radius (typically
90 mm)

(b)

Provide enough space to open the casing with a flat-blade
screwdriver (typically 160 mm)

▪ The  LAN  adapter  is  designed  to  be  wall-mounted  in  dry,  indoor

locations  only.  Make  sure  the  installation  surface  is  a  flat  and
vertical non-combustible wall.

▪ The  LAN  adapter  is  designed  to  be  mounted  in  the  following

orientation only: with the PCB on the right-hand side in the casing,
and the Ethernet connector facing the floor.

▪ The  LAN  adapter  is  designed  to  operate  in  ambient  temperature

ranging from 5~35°C.

Do NOT install the LAN adapter in the following places:

▪ In places with high humidity (max. RH=95%), such as bathrooms.

▪ In places where frost is possible.

4.2

Overview of electrical connections

Connectors

X4A

4
N
L

3

2

1

2

1

230 V AC

X1A

X2A

X3A

b

a

c

d

b

e

a

BRP069A61 only

b

To digital inputs of solar inverter / energy management
system

c

To electrical pulse meter

d

To indoor unit

e

To router

Connections

Connection

Cable section

Wires

Maximum

cable length

Accessory cables

Router (X4A)

50/100 m

(a)

Field-supplied cables

Summary of Contents for BRP069A61

Page 1: ...Installer reference guide Daikin Altherma LAN adapter English Installer reference guide Daikin Altherma LAN adapter BRP069A61 BRP069A62...

Page 2: ...Recommended ON mode 11 7 2 1 Energy buffering 12 7 2 2 Power limitation 12 7 3 Forced OFF mode 12 7 4 Forced ON mode 12 8 Troubleshooting 12 8 1 Overview Troubleshooting 12 8 2 Solving problems based...

Page 3: ...mmended ON Forced ON or Forced OFF Smart Grid operation mode LED OFF system running in the Normal operation Smart Grid operation mode LED flashing LAN adapter performing a Smart Grid compatibility che...

Page 4: ...m a 160 mm b a Provide enough space to connect the Ethernet cable without exceeding its minimum bend radius typically 90 mm b Provide enough space to open the casing with a flat blade screwdriver typi...

Page 5: ...igital inputs of a solar inverter energy management system and allows for use of the Daikin Altherma system in various Smart Grid applications X1A N L supply a detection voltage to the input contact o...

Page 6: ...e to remove any sharp edges that might arise around the holes this to protect the wiring from damage INFORMATION Letting the wiring enter the adapter from the rear allows you to hide the wiring in the...

Page 7: ...indoor unit The 2 wires from the cable are NOT polarised When connecting them to the terminals their polarity does NOT matter 1 When entering the wiring from the bottom inside the LAN adapter casing e...

Page 8: ...t the digital input to the X1A 1 2 LAN adapter digital input X4A X1A X2A X3A S1S L N 4 L N 3 2 1 To connect to a voltage free contact Smart Grid If the solar inverter energy management system has a vo...

Page 9: ...using the Online Controller app using a micro SD card using the configuration web interface INFORMATION For ease of use and to save time it is recommended to update the LAN adapter software using the...

Page 10: ...URL Prerequisite Your computer is connected to the same router the LAN adapter is connected to Prerequisite The router supports DHCP 1 In your browser go to http altherma local Workaround LAN adapter...

Page 11: ...is manually 6 5 1 To remove the LAN adapter from the system 1 On the user interface go to A 2 2 Installer settings System layout Options 2 In the options list select LAN adapter 3 Select No 7 Smart Gr...

Page 12: ...the configuration web interface During energy buffering the power consumption of the Daikin Altherma unit will NOT exceed this limit Dynamic power limitation To enable dynamic power limitation the sys...

Page 13: ...LAN adapter 3 In your browser go to the fixed IP address Result The configuration web interface opens 4 On the configuration web interface go to Network settings and define a fixed IP address Static...

Page 14: ...RP069A61 Full smart grid functionality Router SD Card PV with controllable wall socket PV with potential free contact Electric pulse meter 5 V DC pulse detection supplied by PCB Hydro SWB A3P LAN adap...

Page 15: ......

Page 16: ...4P464229 1A 2017 11 Copyright 2017 Daikin...