10
English
NOTES
•
Cannot have two remote controller control
system with only wireless remote
controllers. (It will be a two remote
controller control system having one wired
and one wireless remote controllers.)
•
Under two remote controller control
system, wireless remote controller cannot
control timer operation.
•
Only the operating indicator lamp out of 3
other lamps on the indoor unit display
functions.
NOTE
•
Contact your Daikin dealer in case of
changing the combination or setting of
group control and two remote controller
control systems.
The following symptoms do not indi-
cate air conditioner malfunction
I.
THE SYSTEM DOES NOT OPERATE
• The system does not restart immedi-
ately after the ON/OFF button is
pressed.
If the OPERATION lamp lights, the sys-
tem is in normal condition. It does not
restart immediately because a safety
device operates to prevent overload of
the system. After 3 minutes, the sys-
tem will turn on again automatically.
• The system does not restart immedi-
ately when TEMPERATURE SETTING
button is returned to the former posi-
tion after pushing the button.
It does not restart immediately because a
safety device operates to prevent overload
of the system. After 3 minutes, the system
will turn on again automatically.
• If the reception beep is rapidly repeated
3 times (It sounds only twice when
operating normally.)
6. NOT MALFUNCTION OF
THE AIR CONDITIONER
Control is set to the optional controller for
centralized control.
• If the defrost lamp on the indoor unit’s
display is lit when heating is started.
This indication is to warn against cold air
being blown from the unit. There is
nothing wrong with the equipment.
I.
EMERGENCY STOP
When the air conditioner stops in emergency,
the run lamp on the indoor unit starts
blinking. Take the following steps yourself to
read the malfunction code that appears on
the display. Contact your dealer with this
code. It will help pinpoint the cause of the
trouble, speeding up the repair.
Press the INSPECTION/TEST button
to select the inspection mode “
”.
“
” appears on display and blinks. “UNIT”
lights up.
Press PROGRAMMING TIMER BUT-
TON and change the unit number.
Press to change the unit number until the
indoor unit beeps and perform the following
operation according to the number of beeps.
Number of beeps
3 short beeps .... Perform all steps from
to .
1 short beep ...... Perform
and
steps
1 long beep........ Normal state
7. HOW TO DIAGNOSE
TROUBLE SPOTS
1
TEST
2
DOWN
UP
3
6
3
6