English
5
Refer to figure 1 on page [1]
•
Operating procedure varies with heat
pump type and cooling only type. Contact
your Daikin dealer to confirm your system
type.
•
To protect the unit, turn on the main power
switch 6 hours before operation.
•
If the main power supply is turned off dur-
ing operation, operation will restart auto-
matically after the power turns back on
again.
Operate in the following order.
•
AUTOMATIC OPERATION can be
selected only by Heat pump split system or
Heat recovery VRV system.
•
For cooling only type, “COOLING”, and
“FAN” and “DRY”operation are able to
select.
〈〈
〈〈
〈〈
〈〈
FOR SYSTEMS WITHOUT COOL/
HEAT CHANGEOVER REMOTE
CONTROL SWITCH
〉〉
〉〉
〉〉
〉〉
Refer to figure 1-1, 2 on page [1]
OPERATION MODE
SELECTOR
Press OPERATION MODE SELECTOR
button several times and select the
OPERATION MODE of your choice as
follows.
COOLING OPERATION .................... “
”
HEATING OPERATION..................... “
”
AUTOMATIC OPERATION................ “
”
•
In this operation mode, COOL/HEAT
changeover is automatically conducted.
FAN OPERATION.............................. “
”
DRY OPERATION ............................. “
”
5. OPERATION PROCEDURE
COOLING, HEATING, AUTOMATIC,
FAN, AND PROGRAM DRY
OPERATION
1
MODE
•
The function of this program is to
decrease the humidity in your room with
the minimum temperature decrease.
•
Micro computer automatically
determines TEMPERATURE and FAN
SPEED.
•
This system does not go into operation if
the room temperature is below 16°C.
ON/OFF
Press ON/OFF button
OPERATION lamp lights up or goes off and
the system starts or stops OPERATION.
NOTE
•
Do not turn OFF power immediately after
the unit stops. Then, wait no less than
5 minutes.
Water is leaking or there is something else
wrong with the unit.
〈〈
〈〈
〈〈
〈〈
FOR SYSTEMS WITH COOL/HEAT
CHANGEOVER REMOTE CONTROL
SWITCH
〉〉
〉〉
〉〉
〉〉
Refer to figure 1-1,3 on page [1]
OPERATION MODE
SELECTOR
(1) Select OPERATION MODE with the
COOL/HEAT CHANGEOVER REMOTE
CONTROL SWITCH as follows.
COOLING OPERATION............. “
”
HEATING OPERATION.............. “
”
FAN OPERATION ...................... “
”
DRY OPERATION ...................... “
”
•
See “FOR SYSTEM WITHOUT COOL/
HEAT CHANGEOVER REMOTE CON-
TROL SWITCH” for details on dry operation.
2
ON OFF
1