background image

BRC2E52C7

BRC3E52C7

WIRED REMOTE 

CONTROLLER 

OPERATION MANUAL

 • Thank you for purchasing the wired remote controller.
 • This manual describes safety precautions required for the use of the 

product.

Read this manual carefully and be sure you understand the 

information provided before attempting to use the product.  

Keep this manual where it is readily accessible after reading it through. 
If another user operates the product in the future, be sure to hand over 
this manual to the new user.

Summary of Contents for BRC2E52C

Page 1: ...ty precautions required for the use of the product Read this manual carefully and be sure you understand the information provided before attempting to use the product Keep this manual where it is read...

Page 2: ...Setting the Cooling Heating Selection Eligibility 19 Key Lock 22 Quick Reference of Main Menu Items The Main Menu Items Overview 23 Menu Manipulation Main Menu 27 Airflow Direction 28 Individual Air D...

Page 3: ...may result in personal injury or loss of life CAUTION Failure to observe these instructions properly may result in property damage or personal injury which may be serious depending on the circumstanc...

Page 4: ...t or outlet Injury may result due to contact with the air conditioner s highspeed fan blades Contact professional personnel about attachment of accessories and be sure to use only accessories specifie...

Page 5: ...burning odour etc turn off the power and contact your local dealer Continued operation under such circumstances may result in a failure electric shocks or fire hazards Consult your local dealer regard...

Page 6: ...concerned Do not place water containers flower vases etc on the unit as this may result in electric shocks or fire Do not use the air conditioner for purposes other than those for which it is intended...

Page 7: ...se of an incorrect washing method or incorrect detergent may damage the resin parts of the indoor unit or cause water leakage Moreover malfunctions smoke generation or ignition may result if the elect...

Page 8: ...i e ON OFF operation mode selection fan speed and temperature settings are set from the menu screen NOTE Do not install the remote controller in places exposed to direct sunlight Otherwise the LCD may...

Page 9: ...item on the lower side will be highlighted Keep pressing the button to cycle through the values or items Used to change the selected item 6 Right button Used to highlight the next items on the right h...

Page 10: ...ir conditioner is in automatic heating operation Standard display 28 C 6 Ventilation purifying 5 Error 12 Under centralized control 13 Changeover under control 3 Set temperature display 4 Defrost Hot...

Page 11: ...r the air conditioner is displayed When the unit is turned OFF and Setback is disabled the temperature that is set for the air conditioner is displayed When the unit is turned OFF and Setback is enabl...

Page 12: ...ff command from a BACnet interface Refer to the service manual of the outdoor unit or contact your local dealer 12 Under Centralized control Indicates that the air conditioner is under the management...

Page 13: ...screen like the one on the left will appear Operation Method Remote Controller Functions Operation procedure Operate the buttons according to the procedure Button display Displays the positions of th...

Page 14: ...geover under control is not displayed on the remote controller The cooling or heating mode cannot be selected if the above is displayed on the remote controller See Setting the Cooling Heating Selecti...

Page 15: ...e air conditioner will stop operating and the Operation lamp will turn OFF Note When the system is stopped while in heating operation the fan will continue to operate for approximately 1 minute in ord...

Page 16: ...When the air conditioner goes into heating operation or defrost operation the indoor unit fan will stop in order to prevent a cold draft In that case Defrost Hot start will be displayed on the remote...

Page 17: ...y mode is selected Note Dry mode may not be available depending on the type of indoor unit 2 Press the ON OFF button The Operation lamp will be lit and the air conditioner will start operating Note Th...

Page 18: ...If the room temperature drops below 10 C heating is started automatically If after half an hour the temperature increases to 12 C or above the controller returns to its original state If the room tem...

Page 19: ...hours before starting the operation of the system Do not turn OFF the air conditioner in season in order to ensure the smooth starting of the air conditioner Press the Operation Mode Selector button s...

Page 20: ...er under control if a cooling heating selection eligibility is granted to the remote controller The icon Changeover under control on each remote controller of indoor units connected to the same outdoo...

Page 21: ...con Changeover under control will disappear The icon Changeover under control will appear on the other remote controllers 3 28 C Press the Operation Mode Selector button on the remote controller that...

Page 22: ...without Changeover under control displayed with Changeover under control displayed The air conditioner will go into the mode set in the remote controller with the selection eligibility No other modes...

Page 23: ...oling heating auto fan selection eligibility in one of the remote controllers BS Branch Selection box The BS box is used for cooling or heating mode selection Indoor unit Indoor unit Heat Recovery sys...

Page 24: ...case of SkyAir maximum 4 units unit A B C D In case of VRV maximum 16 units unit 0 till 15 29 Individual Setting List A table for each unit with the settings for each of the 4 flaps 30 Reset All Indiv...

Page 25: ...Possible to set from 30 to 120 minutes in 30 minute increments 41 Off Timer The system is turned off automatically after the selected time each time the system is activated Possible to set in 10 minu...

Page 26: ...function can be enabled or disabled 51 Display Display Switch between Standard or Detailed display Detailed display settings Select if room temperature outdoor temperature system or nothing is display...

Page 27: ...er Indoor unit Outdoor unit 2 remote controllers in control If 2 remote controllers are in control of a single indoor unit the following menu items are not set in the sub remote controller Set them in...

Page 28: ...ems from the Main Menu 1 Press the Up Down buttons to select the desired item 2 Press the Menu Enter button to display the selected settings screen 4 To go back to the Basic Screen from the Main Menu...

Page 29: ...urn to the Basic Screen Note The airflow directions appear on the screen as follows 1 2 3 4 0 Up down direction 0 1 2 3 4 Left right direction 0 Position 0 1 Position 1 2 Position 2 3 Position 3 4 Pos...

Page 30: ...etting Airflow Direction Range Individual Air Direction Setting Return Select Individual Setting and press the Menu Enter button 3 Return Setting No Ind Set Outletmark Unit A Individual Setting Direct...

Page 31: ...nge Individual Air Direction Setting Return Display the Individual Air Direction menu See Individual Setting on page 29 Press the Up Down buttons to select Individual Setting List and press the Menu E...

Page 32: ...nditioner The Airflow Direction Range has the following 3 patterns Standard Left Blow Right Blow Fully wide swing Swing on the left side Swing on the right side These patterns correspond with the situ...

Page 33: ...tton to select the Air range setting Select the desired air range from Standard Right blow or Left blow by using the Up Down buttons Press the Menu Enter button to confirm the settings and to return t...

Page 34: ...ing the room to a comfortable temperature The fan speed icons disappear and the fan speed cannot be changed Cannot be set when in Fan Only and Dry mode Quick Start will run for a maximum of 30 minutes...

Page 35: ...ly modes that can be set are displayed Ventilation Mode 1 2 2 Ventilation Rate Ventilation Mode Ventilation Setting Return Display the Ventilation menu See Ventilation Rate on page 33 Press the Up Dow...

Page 36: ...set temperature and the Heat Reclaim Ventilation unit indoor and outdoor temperatures the mode is automatically changed between Energy Reclaim Ventilation and Bypass Energy reclaim ventilation mode T...

Page 37: ...Condition Sensing Sensor Low Sensing Sensor Stop Setpoint Auto Reset 1 2 Energy Saving Options Setting Return Press the Up Down buttons to select Energy Saving List and press the Menu Enter button 3 S...

Page 38: ...Move the cursor using the Left Right buttons Press the Menu Enter button when all changes are made The confirmation screen will appear Note The default setpoint range restriction is 16 C 32 C This se...

Page 39: ...ove the cursor using the Left Right buttons Press the Menu Enter button when all changes are made The confirmation screen will appear 3 No Yes Setback Condition Save the settings Setting Return Press...

Page 40: ...ust Heat SP Adjust Time Heat Limit Heat SP Sensing Sensor Low 1 0 C 15 min 35 C 1 0 C 15 min 15 C Setting Return Press the Up Down buttons to set the energy saving operation when the sensor detects an...

Page 41: ...ensing Sensor Stop Setting Return Press the Up Down buttons to set the energy saving operation when the sensor detects the absence Move the cursor using the Left Right buttons Press the Menu Enter but...

Page 42: ...20 C 30 min Cool Heat 2 2 Set temp Set Time Set temp Set Time Setpoint Auto Reset Setting Return Press the Up Down buttons to set the preset temperature and timing for the auto reset of the setpoint M...

Page 43: ...unit it will automatically turn off in minutes Use the Up Down buttons to set the time after which the unit automatically turns off again Selections can be made in increments of 10 minutes from 30 to...

Page 44: ...e Menu Enter button 2 0 6 12 18 24 Total 10 5 kWh 1 kWh Today Energy consumption Return Total 60 2 kWh 10 kWh S M T W T F S This week Energy consumption Return Total 150 kWh 1 kWh 0 3 6 9 12 This year...

Page 45: ...nesday 1 Day 1 Month 2014 Year Setting Date Time Return Note Before setting the schedule the clock must be set If the clock has not been set a screen like the one on the left will appear Press the Lef...

Page 46: ...ee Enable Disable on page 44 Press the Up Down buttons to select Select Schedule and press the Menu Enter button 2 Schedule nr 1 Schedule Select Schedule Setting Return Press the Up Down buttons to se...

Page 47: ...ted as holidays To re enable the schedule timer for the day selected as a holiday the holiday setting must be released 3 Sat Fri Thu Wed Tue Mon Sun Holidays Multiple selection Schedule Setting Return...

Page 48: ...selected schedule see Select Schedule on page 45 2 Mon Schedule nr 1 Setting Return Time Act Cool Heat Press the Up Down buttons to select the day to be set 3 Setting Return Time Act Cool Heat 6 00 Sc...

Page 49: ...rature setpoint for this time period is not specified The last active setpoint will be utilized Indicates that the setback function is disabled for this time period Time Act Cool Heat 6 00 ON 24 C 21...

Page 50: ...nu See Manipulating the Main Menu on page 27 Press the Up Down buttons to select Filter Auto Clean and press the Menu Enter button Note When filter Auto Clean has been disabled the message Auto Filter...

Page 51: ...odel 000 Maintenance Information Return The phone number for the contact address will appear at the top of the screen If you have not yet registered your product it will not appear The model informati...

Page 52: ...2 Draft Prevention Display Contrast Adjustment Configuration Setting Return Press the Up Down buttons to select Draft Prevention and press the Menu Enter button 3 Disable Draft Prevention Enable Disa...

Page 53: ...s the Menu Enter button 2 Display Mode Standard Display Item None Display Setting Return Press the Up Down buttons to select Display Mode and press the Menu Enter button 3 Standard Display Display Mod...

Page 54: ...llowing regarding the display of the room and outdoor temperature Room Temp The temperature near the remote controller The temperature that is detected may be affected by the location of the unit It i...

Page 55: ...nance Information Configuration Current Settings Clock Calendar Language Main Menu Setting Return Display the Main Menu See Manipulating the Main Menu on page 27 Press the Up Down buttons to select Cu...

Page 56: ...00 Wednesday 1 Day 1 Month 2014 Year Setting Date Time Return Use the Up Down buttons to change the date and time Move the cursor using the Left Right buttons Press the Menu Enter button when all chan...

Page 57: ...lock and press the Menu Enter button 2 24H 12H 24H Clock Setting Return Press the Up Down buttons to select 12H or 24H The confirmation screen will appear when the Menu Enter button is pressed Note By...

Page 58: ...enu on page 27 Press the Up Down buttons to select Language and press the Menu Enter button 2 English Language Setting Return Press the Up Down buttons to select the prefered language Press the Menu E...

Page 59: ...g the Main Menu on page 27 Press the Up Down buttons to select Reset Filter Indicator Press the Menu Enter button to reset the filter indicator and to return to the Basic Screen The icon s shown in St...

Page 60: ...the LCD display and the rest of the surface of the remote controller with a dry cloth when they become dirty If the dirt on the surface cannot be removed soak the cloth in neutral detergent diluted wi...

Page 61: ...curs the error icon in the Basic Screen and the operation lamp will blink If a warning occurs only the error icon will blink and the operation lamp will not blink To display the error code and contact...

Page 62: ...ult your Daikin dealer Advise the repairer of the following items Model name Date of installation Failure conditions As precise as possible Your address name and telephone number Relocation The reloca...

Page 63: ......

Page 64: ...Copyright 2014 Daikin 4P368042 1 2014 02...