6 Operation

Installation and operation manual

5

BK+S
Wired remote controller
4P513691-1B – 2018.03

Icon

Description

Demand control. 

Indicates that the system's energy

consumption is being limited, and that it is running
with restricted capacity.

End of demand control. 

Indicates that the system's

energy consumption is no longer being limited, and
that it is no longer running with restricted capacity.

Rotation.

 Indicates that Rotation mode is active.

Setback

. Indicates that the indoor unit is operating

under setback conditions.

Ventilation

. Indicates that a heat reclaim ventilation

unit is connected.

INFORMATION

▪ For  information  on  the  operation  mode  and  ventilation

mode  icons,  see 

"6.1  Operation  mode"  on  page  5

and 

"6.5.1 Ventilation mode" on page 6

 respectively.

▪ Most  icons  are  related  to  things  set  in  the  Daikin

Control  Assistant  app.  For  more  information,  see  the
app, and the installer and user reference guide.

6

Operation

From  the  home  screen,  press 

  to  enter  the  main  menu.  Use 

and 

 to cycle through the menus. Press 

 again to enter one of

the menus.

INFORMATION

▪ Depending on the type of indoor unit you are operating,

more or less menus may be available.

▪ In  the  main  menu,  the  icon  for  each  menu  reflects  the

current  active  setting  or  mode.  When  operating  the
controller,  the  menu  you  navigate  through  can  look
different from that represented in this manual.

▪ The  controller  only  allows  for  basic  operation  of  the

system.  For  advanced  operation  (setback,  schedule
timer, …), see the Daikin Control Assistant app.

6.1

Operation mode

The indoor unit can operate in various operation modes.

Icon

Operation mode

Cooling.

 In this mode, cooling will be activated as

required by the setpoint.

Heating

. In this mode, heating will be activated as

required by the setpoint.

Fan Only

. In this mode, air circulates without heating

or cooling.

Dry

. In this mode, the air humidity will be lowered with

a minimal temperature decrease.

The temperature and fan speed are controlled
automatically and cannot be controlled by the
controller.

Dry operation will not function if the room temperature
is too low.

Ventilation

.In this mode, the space gets ventilated,

but not cooled or heated.

Icon

Operation mode

Air Clean

. In this mode, the optional air cleaning unit

operates.

Venti Air Clean.

 Combination of ventilation

and air clean operation.

Auto.

 In Auto mode, the indoor unit automatically

switches between heating and cooling mode, as
required by the setpoint.

INFORMATION

Depending  on  the  indoor  unit,  more  or  less  operation
modes are available.

6.1.1

To set the operation mode

1

Navigate to the operation mode menu.

2

Use 

 and 

 to select an operation mode.

3

Press 

 to activate.

Result: 

The  indoor  unit  changes  its  operation  mode  and  the

controller returns to the home screen.

6.2

Setpoint

The setpoint is the target temperature for the Cooling, Heating, and
Auto operation modes.

INFORMATION

The  lower  setpoint  limit  of  the  Cooling  operation  mode  is
20°C,  as  per  UAE  Federal  regulation  UAE.S  5010-5:2016
clause 6, and UAE.S 5010-1:2016 clause 10.

6.2.1

To set the setpoint

Prerequisite: 

The  active  operation  mode  is  either  'Cooling',

'Heating', or 'Auto'.

1

In the home screen, use 

 and 

 to adjust the setpoint.

Result: 

The indoor unit changes its temperature setpoint.

6.3

Clock and calendar

Set a time and date for the indoor units connected to the controller.

6.3.1

To set clock and calendar

1

Navigate to the clock and calendar menu.

Summary of Contents for BRC1H81K

Page 1: ...Installation and operation manual Wired remote controller English Installation and operation manual Wired remote controller BRC1H81W BRC1H81K BRC1H81S...

Page 2: ...ions Please read these general safety precautions carefully before installing air conditioning equipment and be sure to install the equipment correctly Failure to follow these instructions properly ma...

Page 3: ...re how to install or operate the unit contact your dealer After finishing installation Conduct a trial operation to check for faults Explain the user how to operate the controller Ask the user to stor...

Page 4: ...system is operating Bluetooth 1 Indicates that the controller is communicating with a mobile device for use with the Daikin Control Assistant app Centralised control Indicates that the system is contr...

Page 5: ...tion mode Cooling In this mode cooling will be activated as required by the setpoint Heating In this mode heating will be activated as required by the setpoint Fan Only In this mode air circulates wit...

Page 6: ...INFORMATION Ventilation settings can ONLY be made for heat reclaim ventilation units 6 5 1 Ventilation mode The heat reclaim ventilation unit can operate in various operation modes Icon Ventilation m...

Page 7: ...ry to enter the main menu Maintenance screens Clean filter Replace filter Empty dust collector 8 Troubleshooting 8 1 Overview Troubleshooting When the system is in error and the controller presents yo...

Page 8: ...e careful not to distort the rear casing by overtightening the mounting screws 11 2 Connecting the electrical wiring NOTICE The wiring for connection is NOT included NOTICE When wiring run the wiring...

Page 9: ...Maintenance safety precautions WARNING Before carrying out any maintenance or repair activities stop system operation with the controller and turn off the power supply circuit breaker Possible consequ...

Page 10: ......

Page 11: ......

Page 12: ...4P513691 1B 2018 03 Copyright 2017 Daikin APPROVED TA 2017 3281 OMAN TRA TRA TA R 5107 18 D100428 TRA REGISTERED No ER63033 18 DEALER No DA73526 18 005 18 TRC LPD 2018 60...

Reviews: