Daikin BRC1H81K Installation And Operation Manual Download Page 4

3 Buttons

Installation and operation manual

4

BK+S

Wired remote controller

4P513691-1B – 2018.03

For the user

3

Buttons

+

-

c

b d

e

a

a

 ON/OFF

▪ When  OFF,  press  to  turn  ON  the  system.  As  a  result,  the

status indicator (e) will turn ON too.

▪ When  ON,  press  to  turn  OFF  the  system.  As  a  result,  the

status indicator (e) will turn OFF too.

b

 ENTER/ACTIVATE /SET

▪ From the home screen, enter the main menu.
▪ From the main menu, enter one of the submenus.
▪ From  their  respective  submenu,  activate  an  operation/

ventilation mode.

▪ In one of the submenus, confirm a setting.

c

 CYCLE/ADJUST

▪ Cycle left.
▪ Adjust a setting (default: decrease).

d

 CYCLE/ADJUST

▪ Cycle right.
▪ Adjust a setting (default: increase).

INFORMATION

For  a  full  description  of  the  behaviour  of  the  status
indicator, see the installer and user reference guide.

4

Home screens

Depending  on  installer  configuration,  the  controller  either  has  a
standard  or  a  detailed  home  screen.  In  most  cases,  the  standard
home screen gives you only the active operation mode, messages (if
any),  and  the  setpoint  temperature  (in  case  of  Cooling,  Heating,  or
Auto operation mode). The detailed home screen gives you all kinds
of information through status icons.

Standard

Detailed

a

b

c

19

a

b

c

a

Messages

b

Active operation mode

c

Setpoint temperature

INFORMATION

The  controller  is  equipped  with  a  power  saving  function
that  causes  the  screen  to  go  blank  after  a  period  of
inactivity. To make the screen light up again, press one of
the buttons.

5

Status icons

Icon

Description

System operation. 

Indicates that the system is

operating.

Bluetooth

.

1

 Indicates that the controller is

communicating with a mobile device, for use with the
Daikin Control Assistant app.

Centralised control.

 Indicates that the system is

controlled by central control equipment (optional
accessory) and that control of the system by the
controller is limited.

Changeover under centralised control.

 Indicates

that the cooling/heating changeover is under
centralised control by another indoor unit, or by an
optional cool/ heat selector that is connected to the
outdoor unit.

Defrost/Hot start.

 Indicates that the defrost/hot start

mode is active.

Timer.

 Indicates that the schedule timer or OFF timer

is enabled.

Clock not set

. Indicates that controller's clock is not

set.

Self-cleaning filter operation.

 Indicates that self-

cleaning filter operation is active.

Quick Start.

 Indicates that Quick Start mode is active

(Sky Air only).

Test operation.

 Indicates that Test Operation mode

is active (Sky Air only).

Inspection

. Indicates that the indoor or outdoor unit is

being inspected.

Periodic inspection.

 Indicates that the indoor or

outdoor unit is being inspected.

Backup.

 Indicates that in the system an indoor unit is

set as backup indoor unit.

Individual airflow direction

. Indicates that the

individual airflow direction setting is enabled.

Information.

 Indicates that the system has a

message to convey. To see the message, go to the
information screen.

Warning. 

Indicates that an error occurred, or that an

indoor unit component needs to be maintained.

(1)

The Bluetooth® word mark and logos are registered trademarks owned by the Bluetooth SIG, Inc. and use of such marks by
Daikin Europe N.V. is under license. Other trademarks and trade names are those of their respective owners.

Summary of Contents for BRC1H81K

Page 1: ...Installation and operation manual Wired remote controller English Installation and operation manual Wired remote controller BRC1H81W BRC1H81K BRC1H81S...

Page 2: ...ions Please read these general safety precautions carefully before installing air conditioning equipment and be sure to install the equipment correctly Failure to follow these instructions properly ma...

Page 3: ...re how to install or operate the unit contact your dealer After finishing installation Conduct a trial operation to check for faults Explain the user how to operate the controller Ask the user to stor...

Page 4: ...system is operating Bluetooth 1 Indicates that the controller is communicating with a mobile device for use with the Daikin Control Assistant app Centralised control Indicates that the system is contr...

Page 5: ...tion mode Cooling In this mode cooling will be activated as required by the setpoint Heating In this mode heating will be activated as required by the setpoint Fan Only In this mode air circulates wit...

Page 6: ...INFORMATION Ventilation settings can ONLY be made for heat reclaim ventilation units 6 5 1 Ventilation mode The heat reclaim ventilation unit can operate in various operation modes Icon Ventilation m...

Page 7: ...ry to enter the main menu Maintenance screens Clean filter Replace filter Empty dust collector 8 Troubleshooting 8 1 Overview Troubleshooting When the system is in error and the controller presents yo...

Page 8: ...e careful not to distort the rear casing by overtightening the mounting screws 11 2 Connecting the electrical wiring NOTICE The wiring for connection is NOT included NOTICE When wiring run the wiring...

Page 9: ...Maintenance safety precautions WARNING Before carrying out any maintenance or repair activities stop system operation with the controller and turn off the power supply circuit breaker Possible consequ...

Page 10: ......

Page 11: ......

Page 12: ...4P513691 1B 2018 03 Copyright 2017 Daikin APPROVED TA 2017 3281 OMAN TRA TRA TA R 5107 18 D100428 TRA REGISTERED No ER63033 18 DEALER No DA73526 18 005 18 TRC LPD 2018 60...

Reviews: