Indoor Unit Installation

1.

Installing the mounting plate

• The mounting plate should be installed on a wall which can support the weight of the indoor unit.
1) Temporarily secure the mounting plate to the wall, make sure that the panel is completely level, and mark the boring points 

on the wall.

2) Secure the mounting plate to the wall with screws.

Recommended mounting plate retention spots and dimensions

2.

Boring a wall hole and installing wall embedded pipe

• For walls containing metal frame or metal board, be sure to use a wall 

embedded pipe and wall cover in the feed-through hole to prevent possible 
heat, electrical shock, or fire.

• Be sure to caulk the gaps around the pipes with caulking material to 

prevent water leakage.

1) Bore a feed-through hole of 65/80mm in the wall so it has a down slope 

toward the outside.

2) Insert a wall pipe into the hole.
3) Insert a wall cover into wall pipe.

337

810

A

A

294

44.5

170

142

170

447

60

435

990

1040

170

151.5

52

19.5

126.5

48

60

52

300

19.5

117

68

68

44.5

137

137

337

50

213

237

170

Place the pipe port cover
in this pocket.

Place a leveler 
on these tabs.

Recommended mounting plate 
retention spots (7 spots in all)

Through-the-wall 
hole 

I

65

Drain hose position

Gas pipe end

Liquid pipe end

Use a tape measure 
as shown.

Position the end of 
the tape measure at    .

The removed pipe 

port cover can be 

kept in the mounting 

plate pocket.

Mounting 
plate

Removed pipe
port cover

A

Class 15/20/25/35/42:

Class 50/60/71:

PIPING HOLE
CENTER:170mm
TO THE LEFT

PIPING HOLE
CENTER:170mm
TO THE LEFT

Place a leveler 
on these tabs.

Gas pipe end

Liquid pipe end

Through-the-wall 
hole 

I

80

Drain hose 
position

Recommended mounting 
plate retention spots 
(5 spots in all)

(Outline of back side)

(Outline of front side)

Inside

Outside

Caulking

Wall embedded pipe 
(field supply)

Wall hole cover
(field supply)

Wall embedded pipe 
(field supply)

65/ 80

3PEN393185-7L.book  Page 5  Friday, February 26, 2016  7:49 AM

Summary of Contents for ATXM20M2V1B

Page 1: ...2 Split Series English Deutsch Français Nederlands Español Italiano Eλληνικά Portugues Pyccкий Türkçe MODELS CTXM15M2V1B FTXM60M2V1B FTXM20M2V1B FTXM71M2V1B FTXM25M2V1B ATXM20M2V1B FTXM35M2V1B ATXM25M2V1B FTXM42M2V1B ATXM35M2V1B FTXM50M2V1B ATXM50M2V1B ...

Page 2: ...tificato C 07 Σημείωση όπως καθορίζεται στο A και κρίνεται θετικά από το B σύμφωνα με το Πιστοποιητικό C 08 Nota tal como estabelecido em A e com o parecer positivo de B de acordo com o Certificado C 09 Примечание как указано в A и в соответствии с положительным решением B согласно Свидетельству C 10 Bemærk som anført i A og positivt vurderet af B i henhold til Certifikat C 11 Information enligt A...

Page 3: ...ente da B secondo il Certificato C 07 Σημείωση όπως καθορίζεται στο A και κρίνεται θετικά από το B σύμφωνα με το Πιστοποιητικό C 08 Nota tal como estabelecido em A e com o parecer positivo de B de acordo com o Certificado C 09 Примечание как указано в A и в соответствии с положительным решением B согласно Свидетельству C 10 Bemærk som anført i A og positivt vurderet af B i henhold til Certifikat C...

Page 4: ...Make sure that all wiring is secured the specified wires are used and that there is no strain on the terminal connections or wires Improper connections or securing of wires may result in abnormal heat build up or fire When wiring the power supply and connecting the wiring between the indoor and outdoor units position the wires so that the control box lid can be securely fastened Improper positioni...

Page 5: ...and find the site where remote controller signals are properly received by the indoor unit within 7m CAUTION Do not install the air conditioner at any place where there is a danger of flammable gas leakage In the event of a gas leakage build up of gas near the air conditioner may cause a fire to break out Only qualified personnel can handle fill purge and dispose of the refrigerant While following...

Page 6: ...ar protection gloves Place both hands under the centre of the front grille and while pushing up pull it toward you Installation method 1 Install the front grille and firmly engage the upper hooks 3 locations 2 Install 2 screws 3 screws of the front grille 3 Install the air filter and then mount the front panel 3 How to set the different addresses When 2 indoor units are installed in one room the 2...

Page 7: ...ng method 1 Remove the service lid screw 2 Pull out the service lid diagonally down in the direction of the arrow 3 Pull down 30mm or more from ceiling Front panel 50mm or more from walls on both sides LU OWHUV Mounting plate Mounting plate LQJ VFUew HOG VXSSO M4 25L Wireless remote controller L LQJ VFUew for remote controller holder HOG VXSSO M3 20L Remote controller holder Before screwing the re...

Page 8: ...tside 2 Insert a wall pipe into the hole 3 Insert a wall cover into wall pipe 337 810 A A 294 44 5 170 142 170 447 60 435 990 1040 170 151 5 52 19 5 126 5 48 60 52 300 19 5 117 68 68 44 5 137 137 337 50 213 237 170 Place the pipe port cover in this pocket Place a leveler on these tabs Recommended mounting plate retention spots 7 spots in all Through the wall hole I65 Drain hose position Gas pipe e...

Page 9: ...6 English 4 After completing refrigerant piping wiring and drain piping caulk pipe hole gap with putty ...

Page 10: ... with both hands to set it on the mounting plate hooks Make sure the wires do not catch on the edge of the indoor unit In the case of bending or curing refrigerant pipes keep the following precautions in mind Abnormal sound may be generated if improper work is conducted 1 Do not strongly press the refrigerant pipes onto the bottom frame 1 Cut off the pipe port cover from inside the front grille us...

Page 11: ...nto the left side 1 Remove the insulation fixing screw on the right and remove the drain hose 2 Remove the drain plug on the left side and attach it to the right side 3 Insert the drain hose and tighten with included insulation fixing screw Forgetting to tighten this may cause water leakages Drain hose attachment position The drain hose is on the back of the unit Front side of unit Attachment on t...

Page 12: ...R C CAPACITOR Q L OVERLOADPROTECTOR CN E AC HA HE HL HN HR MR _A MR _B S X A CONNECTION CONNECTOR Q M THERMOSWITCH D V D DIODE R RESISTOR DB DIODEBRIDGE R T THERMISTOR DS DIPSWITCH RC RECEIVER E H HEATER S C LIMITSWITCH F U FU FORCHARACTERISTICS REFERTOPCBINSIDE YOURUNIT FUSE S L FLOATSWITCH FG CONNECTOR FRAMEGROUND S NPH PRESSURESENSOR HIGH H HARNESS S NPL PRESSURESENSOR LOW H P LED V L PILOTLAMP...

Page 13: ... is required use appropriate parts that match the hose front end Figure of hose front end 4 When extending the drain hose use a commercially available extension hose with an inner diameter of 16mm Be sure to thermally insulate the indoor section of the extension hose 5 When connecting a rigid polyvinyl chloride pipe nominal diameter 13mm directly to the drain hose attached to the indoor unit as wi...

Page 14: ...ter against the hooks 1 Lock the adapter by pressing it down 2 Removing the reverse process of installing Class 50 60 71 Installing Place the wireless adapter into the holder 1 Fix the adapter in the holder by pressing down on it 2 Removing Bend one clamp of the holder with the finger to release the wireless adapter 1 Remove it from the holder 2 Remove tape Cut the clip Remove the connector from p...

Page 15: ... of both flares and tighten the flare nuts 3 or 4 turns by hand Then tighten them fully with the torque wrenches 2 1 Caution on piping handling 1 Protect the open end of the pipe against dust and moisture 2 All pipe bends should be as gentle as possible Use a pipe bender for bending A A Cut exactly at right angles Remove burrs Flaring Set exactly at the position shown below Die 0 0 5mm Clutch type...

Page 16: ... standby mode If the system is not to be used for some time after installation shut off the circuit breaker to eliminate unnecessary power consumption If the circuit breaker trips to shut off the power to the air conditioner the system will restore the original operation mode when the circuit breaker is opened again 2 Test items Gas side Liquid side Gas pipe thermal insulation Liquid pipe thermal ...

Page 17: ......

Page 18: ...3P393185 7L 2015 12 Copyright 2015 Daikin ...

Reviews: