Indoor Unit Installation

3-2. Left-side, left-back, or left-bottom piping

1) Attach the drain hose to the underside of the refrigerant pipes 

with adhesive vinyl tape.

2) Be sure to connect the drain hose to the drain port in place of 

a drain plug.

3) Shape the refrigerant pipes along the pipe 

path marking on the mounting plate.

4) Pass the drain hose and refrigerant pipes 

through the wall hole, then set the indoor 
unit on mounting plate hooks, using the 

markings at the top of the indoor unit as 

a guide.

5) Pull in the inter-unit wire.
6) Connect the inter-unit pipes.

7) Wrap the refrigerant pipes and drain hose together with insulation tape as 

shown in the figure on the right (in case of setting the drain hose through 
the back of the indoor unit.

8) While exercising care so that the inter-unit wire does not catch indoor unit, 

press the bottom edge of indoor unit with both hands until it is firmly caught 
by the mounting plate hooks. Secure indoor unit to the mounting plate with 
indoor unit fixing screws (M4 × 12L).

3-3. Wall embedded piping

Follow the instructions given under left-side, left-back, or left-bottom piping.
1) Insert the drain hose to this depth so it won’t be pulled out of the drain pipe.

How to replace the drain plug and drain hose

• Replacing onto the left side

1) Remove the insulation fixing screw on the 

right and remove the drain hose.

2) Remove the drain plug on the left side and 

attach it to the right side.

3) Insert the drain hose and tighten with 

included insulation fixing screw.
* (Forgetting to tighten this may cause 
   water leakages.)

Drain hose attachment position

* The drain hose is on the back of the unit.

Front side of unit

Attachment on the right side (factory default)

Attachment on the left side

Drain hose

Drain hose

Insulation 
fixing screw

Insulation 
fixing screw

Left side

Right side

Remove pipe port cover here for left-bottom piping.

Remove pipe 
port cover 
here for left-
side piping.

Left-bottom piping

Left-side 
piping

Left-back 
piping

How to set drain plug

No gap.

Do not apply lubricating 
oil (refrigerant oil) to the 
drain plug when inserting it.
The application of lubrication 
oil to the drain plug will deteriorate 
the plug and cause drain leakage 
from the plug.

Insert a hexagonal wrench (4mm).

Drain 
hose

Caulk this hole 
with putty or 
caulking material.

Bind with adhesive 
vinyl tape.

Mounting plate

Wrap insulating tape around the 
bent portion of refrigerant pipes. 
Overlap at least half the width of 
the tape with each turn.

Refrigerant 
pipes

Drain hose

Bottom frame

Indoor unit fixing screw
(M4 × 12L) (2 locations)

Mounting 
plate

Inter-unit wire

Inner wall

Vinyl chloride 
drain pipe 
(VP-30)

Drain hose

50mm 
or more

Insert drain hose 
to this depth so 
it won’t be pulled 
out of drain pipe.

Outer wall

3PEN393185-7L.book  Page 8  Friday, February 26, 2016  7:49 AM

Summary of Contents for ATXM20M2V1B

Page 1: ...2 Split Series English Deutsch Français Nederlands Español Italiano Eλληνικά Portugues Pyccкий Türkçe MODELS CTXM15M2V1B FTXM60M2V1B FTXM20M2V1B FTXM71M2V1B FTXM25M2V1B ATXM20M2V1B FTXM35M2V1B ATXM25M2V1B FTXM42M2V1B ATXM35M2V1B FTXM50M2V1B ATXM50M2V1B ...

Page 2: ...tificato C 07 Σημείωση όπως καθορίζεται στο A και κρίνεται θετικά από το B σύμφωνα με το Πιστοποιητικό C 08 Nota tal como estabelecido em A e com o parecer positivo de B de acordo com o Certificado C 09 Примечание как указано в A и в соответствии с положительным решением B согласно Свидетельству C 10 Bemærk som anført i A og positivt vurderet af B i henhold til Certifikat C 11 Information enligt A...

Page 3: ...ente da B secondo il Certificato C 07 Σημείωση όπως καθορίζεται στο A και κρίνεται θετικά από το B σύμφωνα με το Πιστοποιητικό C 08 Nota tal como estabelecido em A e com o parecer positivo de B de acordo com o Certificado C 09 Примечание как указано в A и в соответствии с положительным решением B согласно Свидетельству C 10 Bemærk som anført i A og positivt vurderet af B i henhold til Certifikat C...

Page 4: ...Make sure that all wiring is secured the specified wires are used and that there is no strain on the terminal connections or wires Improper connections or securing of wires may result in abnormal heat build up or fire When wiring the power supply and connecting the wiring between the indoor and outdoor units position the wires so that the control box lid can be securely fastened Improper positioni...

Page 5: ...and find the site where remote controller signals are properly received by the indoor unit within 7m CAUTION Do not install the air conditioner at any place where there is a danger of flammable gas leakage In the event of a gas leakage build up of gas near the air conditioner may cause a fire to break out Only qualified personnel can handle fill purge and dispose of the refrigerant While following...

Page 6: ...ar protection gloves Place both hands under the centre of the front grille and while pushing up pull it toward you Installation method 1 Install the front grille and firmly engage the upper hooks 3 locations 2 Install 2 screws 3 screws of the front grille 3 Install the air filter and then mount the front panel 3 How to set the different addresses When 2 indoor units are installed in one room the 2...

Page 7: ...ng method 1 Remove the service lid screw 2 Pull out the service lid diagonally down in the direction of the arrow 3 Pull down 30mm or more from ceiling Front panel 50mm or more from walls on both sides LU OWHUV Mounting plate Mounting plate LQJ VFUew HOG VXSSO M4 25L Wireless remote controller L LQJ VFUew for remote controller holder HOG VXSSO M3 20L Remote controller holder Before screwing the re...

Page 8: ...tside 2 Insert a wall pipe into the hole 3 Insert a wall cover into wall pipe 337 810 A A 294 44 5 170 142 170 447 60 435 990 1040 170 151 5 52 19 5 126 5 48 60 52 300 19 5 117 68 68 44 5 137 137 337 50 213 237 170 Place the pipe port cover in this pocket Place a leveler on these tabs Recommended mounting plate retention spots 7 spots in all Through the wall hole I65 Drain hose position Gas pipe e...

Page 9: ...6 English 4 After completing refrigerant piping wiring and drain piping caulk pipe hole gap with putty ...

Page 10: ... with both hands to set it on the mounting plate hooks Make sure the wires do not catch on the edge of the indoor unit In the case of bending or curing refrigerant pipes keep the following precautions in mind Abnormal sound may be generated if improper work is conducted 1 Do not strongly press the refrigerant pipes onto the bottom frame 1 Cut off the pipe port cover from inside the front grille us...

Page 11: ...nto the left side 1 Remove the insulation fixing screw on the right and remove the drain hose 2 Remove the drain plug on the left side and attach it to the right side 3 Insert the drain hose and tighten with included insulation fixing screw Forgetting to tighten this may cause water leakages Drain hose attachment position The drain hose is on the back of the unit Front side of unit Attachment on t...

Page 12: ...R C CAPACITOR Q L OVERLOADPROTECTOR CN E AC HA HE HL HN HR MR _A MR _B S X A CONNECTION CONNECTOR Q M THERMOSWITCH D V D DIODE R RESISTOR DB DIODEBRIDGE R T THERMISTOR DS DIPSWITCH RC RECEIVER E H HEATER S C LIMITSWITCH F U FU FORCHARACTERISTICS REFERTOPCBINSIDE YOURUNIT FUSE S L FLOATSWITCH FG CONNECTOR FRAMEGROUND S NPH PRESSURESENSOR HIGH H HARNESS S NPL PRESSURESENSOR LOW H P LED V L PILOTLAMP...

Page 13: ... is required use appropriate parts that match the hose front end Figure of hose front end 4 When extending the drain hose use a commercially available extension hose with an inner diameter of 16mm Be sure to thermally insulate the indoor section of the extension hose 5 When connecting a rigid polyvinyl chloride pipe nominal diameter 13mm directly to the drain hose attached to the indoor unit as wi...

Page 14: ...ter against the hooks 1 Lock the adapter by pressing it down 2 Removing the reverse process of installing Class 50 60 71 Installing Place the wireless adapter into the holder 1 Fix the adapter in the holder by pressing down on it 2 Removing Bend one clamp of the holder with the finger to release the wireless adapter 1 Remove it from the holder 2 Remove tape Cut the clip Remove the connector from p...

Page 15: ... of both flares and tighten the flare nuts 3 or 4 turns by hand Then tighten them fully with the torque wrenches 2 1 Caution on piping handling 1 Protect the open end of the pipe against dust and moisture 2 All pipe bends should be as gentle as possible Use a pipe bender for bending A A Cut exactly at right angles Remove burrs Flaring Set exactly at the position shown below Die 0 0 5mm Clutch type...

Page 16: ... standby mode If the system is not to be used for some time after installation shut off the circuit breaker to eliminate unnecessary power consumption If the circuit breaker trips to shut off the power to the air conditioner the system will restore the original operation mode when the circuit breaker is opened again 2 Test items Gas side Liquid side Gas pipe thermal insulation Liquid pipe thermal ...

Page 17: ......

Page 18: ...3P393185 7L 2015 12 Copyright 2015 Daikin ...

Reviews: