![background image](http://html.mh-extra.com/html/daikin/atm24mv2s/atm24mv2s_service-manual_501369022.webp)
Indoor Heat Exchanger
Si041351ED
20
Removal Procedure
6
Slightly widen the
auxiliary piping.
7
Remove the 2 screws
on the left side.
8
Push the hook on the
right side and unfasten
it.
9
Lift up and remove the
indoor heat exchanger.
Step
Procedure
Points
(R22046)
Auxiliary piping
(R13580)
(R16310)
(R16311)
Indoor heat
exchanger