background image

Safety Precautions 

•  Keep this manual where the user can easily find it. 

•  Read the precautions in this manual carefully before operating the unit. 

• The precautions described herein are classified as WARNING 

and CAUTION. They both contain important information regarding 

safety. Be sure to observe all precautions without fail. 

&.WARNING

Failure to follow these instructions properly may result in 

personal injury or loss of life. 

&.CAUTION

Failure to follow these instructions properly may result in 

property damage or personal injury, which may be serious 

depending on the circumstances. 

�  Never attempt. 

Be sure to follow the instructions. 

•  Be sure to establish an earth connection. 

•  After reading,  keep this manual in a convenient place so that you 

can refer to it whenever necessary. If the equipment is transferred 

to a new user, be sure also to hand over the manual. 

&WARNING 

• To avoid fire, explosion or injury, do not operate the unit 

when harmful gases (e.g. flammable or corrosive) are 

detected near the unit. 

(S) 

•  Be aware that prolonged, direct exposure to cool air from the air conditioner, 

or to air that is too cool, can be harmful to your physical condition and health. 

•  Do not place objects, including rods,  your fingers,  etc.,  in the air 

inlet or outlet.  Product  damage may result due to contact with the 

air conditioner's high-speed fan blades. 

•  Do not attempt to repair,  dismantle, reinstall or modify the air conditioner 

yourself as this may  result in water leakage, electric shock or fire hazards. 

•  Do not use flammable spray near the air conditioner, or otherwise 

fire may result. 

•  Do not use a refrigerant other than the one indicated on the outdoor 

unit (R32) when installing, moving or repairing. Using other refrigerants 

may cause trouble or damage to the unit, and personal injury. 

• To avoid electric shock, do not operate with wet hands. 

•  Beware of fire in case  of refrigerant leakage. If the air conditioner is 

not operating correctly, i.e. not generating cool air, refrigerant leakage 

could be the cause. Consult your service centre for assistance. The 

refrigerant within the air conditioner is safe and normally does not leak. 

However, in the event of a leakage, contact with a naked burner, heater or 

cooker may result in  generation of noxious gas. Do  not use the air 

conditioner until a qualified service person confirms that the leakage has 

been repaired. 

•  Do not attempt to install or repair the air conditioner yourself. 

Improper workmanship may result in water leakage, electric 

shock or fire hazards. Please contact your local service centre or 

qualified personnel for installation and maintenance work. 

•  If the air conditioner is malfunctioning (giving off a burning odour, 

etc.), turn off power to the unit and contact your local service 

centre. Continued operation under such circumstances may 

result in a failure, electric shock or fire hazards. 

•  Be sure to install an earth leakage circuit breaker. Failure to install 

the earth leakage circuit breaker may result in electric shock or fire. 

•  Be sure to earth the unit. Do not earth the unit to a utility 

pipe, lightning conductor or telephone earth lead. 

Imperfect earthing may result in electric shock. 

&. CAUTION

---------

•  Do not use the air conditioner for purposes other than 

those for which it is intended. Do not use the air 

(S) 

conditioner for cooling precision instruments, food, plants, 

animals or works of art as this may adversely affect the 

performance, quality and/or longevity of the object concerned. 

•  Do not expose plants or animals directly to the airflow from the 

unit as this may cause adverse effects. 

•  Do not place appliances that produce naked flames in places exposed 

to the airflow from the unit as this may impair combustion of the burner. 

•  Do not block the air inlets  or outlets. Impaired airflow may result 

in insufficient performance or trouble. 

•  Do not sit on the outdoor unit, put things on the unit, or pull the unit. 

Doing so may cause accidents, such as falling or toppling down, 

thus resulting in injury, product malfunctioning, or product damage. 

•  Do not place objects that are susceptible to moisture directly beneath 

the indoor or outdoor units. Under certain conditions, condensation on 

the main unit or refrigerant pipes,  air filter dirt or drain blockage  may 

cause dripping, resulting in fouling or failure of the object concerned. 

•  After prolonged use,  check the unit stand and its mounts for damage. If 

they are left in a damaged condition, the unit may fall and cause injury. 

• To avoid injury,  do not touch the air inlet or aluminium fins of the 

indoor or outdoor units. 

• The appliance is not intended for use by unattended young 

children or infirm persons. Impairment of bodily functions and 

harm to health may result. 

• Children should be supervised to ensure that they do not play with 

the unit or its remote controller. Accidental operation by a child 

may result in impairment of bodily functions and harm health. 

•  Avoid impacts to the indoor and outdoor units, or otherwise 

product damage may result. 

•  Do not place flammable items, such as spray cans, within 1 m of 

the air outlet. The spray cans may explode as a result of hot air 

from the indoor or outdoor units. 

•  Be careful not to let pets urinate on the air conditioner.  Urination 

on the air conditioner may result in electric shock or fire. 

•  Do not wash the air conditioner with water, as this may result in 

electric shock or fire. 

•  Do not place water containers (vases, etc.) above the unit, as this 

may result in electric shock or fire hazards if they should topple over. 

•  Do not insert  the batteries in the wrong po/-) orientation 

as this may result in short circuiting, fire, or battery leakage. 

• To avoid oxygen depletion, ensure that the room is 

adequately ventilated if equipment such as a burner is 

used together with the air conditioner. 

•  Before cleaning, be sure to stop unit operation and turn off 

the circuit breaker. Otherwise, an electric shock and injury may result. 

•  Only  connect the air conditioner to the specified power supply 

circuit. Power supplies other than the one specified may result in 

electric shock, overheating and fires. 

•  Arrange the drain hose to ensure smooth drainage. Imperfect 

drainage may cause wetting of the building, furniture, etc. 

•  Do not place objects in direct proximity of the outdoor unit and do 

not let leaves and other debris accumulate around the unit. 

Leaves are a hotbed for small animals which can enter the unit. 

Once inside the unit, such animals can cause malfunctions, 

smoke or fire if they come into contact with electrical parts. 

•  Do not place objects around the indoor unit. 

Doing so may have an adverse influence on the performance, 

product quality, and life of the air conditioner. 

• This appliance is not intended to be used by persons with reduced 

physical, sensory or mental capabilities, or with lack of operation 

knowledge, unless they have been given supervision or instruction 

concerning the appliance use by person responsible for their safety. 

Keep out of children's reach to ensure that they do not play with the appliance. 

Summary of Contents for ATKL50UV16V3

Page 1: ...DAIKIN 3P665364 9U M22P1 00B DAIKIN ROOM AIR CONDITIONER OPERATION MANUAL MODELS A D F G MTKL50UV16V3 F GTKY35UV16W3 F G MTKM50UV16V3 A D F G MTKL35UV16W3 3P665364 9U M22P1 00B...

Page 2: ...uality and or longevity of the object concerned Do not expose plants or animals directly to the airflow from the unit as this may cause adverse effects Do not place appliances that producenaked flames...

Page 3: ...er Receives signals from the remote controller When the unit receives a signal you will hear a beep sound Case Sound type Operation start beep beep Settings changed beep Operation stop long beep 13 In...

Page 4: ...OFF TIMER button 14 GOOD SLEEP DISPLAY button 15 DEW CLEAN button NOTE Notes on remote controller 7 9 10 14 13 S NO 1 2 7 4 Never expose the remote controller to direct sunlight DAIKIN 011 I I POWER L...

Page 5: ...ontroller Do not get it wet The maximum transmission distance is about 7m To attach the accessory filters i Receiver Set the accessory filters under the tabs of the filter Ac esso yfUte i n h 0 Y u f...

Page 6: ...the accessory filter and the decomposition power of the streamer discharge combine to reduce unpleasant odours and viruses cleaning the air in the room To start operation 1 Press I c I STREAMER When l...

Page 7: ...LD LOCK disables all the buttons except when ECONO and POWERFULL button press together for about 5 seconds To set the CHILD LOCK Press and o_WE_R_c 1L together for about 5 seconds e will be displayed...

Page 8: ...ades will begin to swing The 3 D airflow direction 1 Press 1SWIN and SWING and e are displayed on the LCD The flap and louvres move in turn To cancel 3 D airflow press either 4swiNaj or sw1NG again Th...

Page 9: ...uses the settings to be cancelled and disappears from the LCD ECONO operation functions in COOL and DRY operation POWER CHILL and ECONO operation cannot be used at the same time is displayed on the LC...

Page 10: ...time default 2HR are displayed on the LCD IC O ON OFF c J The TIMER lamp lights Display orange TEMP 2 Press v while C is blinking Each pressing of the button changes tempera ture shift value by 1 c Yo...

Page 11: ...t temperature does not display when the unit is in DRY operation or FAN operation Inverter output and set temperature may not display depending on the operation mode that is active The display turns o...

Page 12: ...Dry mode OFF Cooling operation To cancel DEW CLEAN operation Turn OFF the machine from Remote Controller Wi Fi Control NOTE Note on LED 7 Segment Brightness Control Ld indicates for the brightness Li...

Page 13: ...age the front panel shaft on the other side in the same manner After disengaging both front panel shafts pull the front panel toward yourself and remove it 3 Clean the front panel Wipe it with a soft...

Page 14: ...with a vacuum cleaner If the dust does not come off easily wash them with neutral detergent thinned with lukewarm water then let them dry in the shade Be sure to remove the accessory filter optional p...

Page 15: ...m Titanium apatite deodorizing air purifying filter 1 set Ag ion filter 1 set Anti Microbial filter 1 set Micro filter PM2 5 1 set Micro filter PM2 5 for streamer unit 1 set Micro filter PM 1 0 for st...

Page 16: ...es operation in about 3 minutes Voltage range protection 130V 285V Voltage range protection 130V 265V for F GTKL71UV16T Models A sound is heard A sound like flowing water This sound is generated becau...

Page 17: ...been tripped or the fuse blown operate Is there a power failure OPERATION lamp is off Are batteries set in the remote controller Is the timer setting correct The room does not cool down Is the airflo...

Page 18: ...air conditioner automatically resumes operation in about 3 minutes You should just wait for a while If there is a risk lightning could strike in the neighbourhood stop operation and turn off the circu...

Page 19: ...TART UP E7 DC FAN MOTOR FAULT E8 OVERCURRENT INPUT F3 HIGH TEMPERATURE DISCHARGE PIPE CONTROL F6 HIGH PRESSURE CONTROL IN COOLING F8 OPERATION HALT DUE TO COMPRESSOR INTERNAL TEMPERATURE ABNORMALITY O...

Page 20: ......

Page 21: ...re installed securely Fall vibration noise No refrigerant gas leaks Incomplete cooling function Refrigerant gas and liquid pipes and indoor drain hose Water leakage extension are thermally insulated D...

Page 22: ...as stopvalve sservice port thenfullyopenliquidandgas stop valves Do not attempt to turn valve rod beyond its stop 8 Tighten valve caps and service port caps for the liquid and gas stop valves with a t...

Page 23: ...ue 32 7 39 9N m 21 6 27 4N m O D 9 5mm 333 407 kgf cm 220 280 kgf cm Gas side I 0 D 12 7mm 49 5 60 3N m 48 1 59 7N m 505 615 kgf cm O D 15 9mm 61 8 75 4N m 490 61O kgf cm 10 8 14 7N m 110 150 kgf cm 6...

Page 24: ...cause condensation or water dripping f Heat insulationpipe cover Slit llll lfflll Slit Vinyl tape This illustration shows the case of the left rear piping Sectional view wire Insulation tape Drain hos...

Page 25: ...hthe unit WARNING ____________________________________1_a_b1e_N_o_ 6 Use a stabiliser if required by the voltage supply condition Do not use tapped wires extension cords or starburst connections as th...

Page 26: ...indoor unit to the A mounting plate with the E indoor unit fixing screws M4 x 12L 10 Caulk thegap between the pipeand the front grille with putty 11 After completing refrigerant piping wiring and drai...

Page 27: ...id pipeend Gaspipeend Drainhose position Applicable Unit Size Type H X W X D A B C i 298 X 800 X 229 800 116 5 116 5 298 X 821 X 235 821 128 126 5 298 X 885 X 229 885 116 5 116 5 298 X 906 X 235 906 1...

Page 28: ...you 2 Pun1 _ _r p Installation method 1 Install the front grille and firmly engage the upper hooks 3 locations 2 Install 3 screws of the front grille 3 Install the air filter and then mount the front...

Page 29: ...e length is 3m in order to avoid noise from the outdoor unit and vibration Mechanical noise and vibration may occur depending on how the unit is installed and the environment in which it is used Dimen...

Page 30: ...t the unit may cause interference with the picture or sound 9 the unit can be installed at the recommended height 1 8m 10 no laundry equipment is nearby fflGi l li11 114 The outdoor unit should be pos...

Page 31: ...rant gas leaks during installation ventilate the area immediately 0 Toxic gas may be produced if the refrigerant comes into contact with fire After completing installation check for refrigerant gas le...

Page 32: ...3P665364 9U M22P101B DAIKIN ROOM AIR CONDITIONER INSTALLATION MANUAL l MODELS A D F G MTKL50UV16V3 F GTKV35UV16W3 F G MTKM50UV16V3 A D F G MTKL35UV16W3 J C JNVERTER 3P665364 9U M22P101B...

Reviews: