![background image](http://html.mh-extra.com/html/daikin/at09hv2s/at09hv2s_service-manual_501358022.webp)
Removal of Drain Pan Unit / Swing Motor
Si04-751
20
Removal Procedure
4
Remove the drain pan
unit from the indoor
unit.
When reassembling, make
sure that the hook at the left
side is fitted in the groove.
2. Remove the swing motor.
1
Remove the screw of
the swing motor.
2
Pull out the swing
motor.
Step
Procedure
Points
(R4378)
Hook
(R4379)
(R4380)
Swing motor
(R4381)