Si001277
Electrical Box
Removal Procedure
3
2. Electrical Box
Warning
Be sure to wait for 10 minutes or more after turning off all power supplies before
disassembling work.
Step
Procedure
Points
1
2
Remove the 3 screws
and remove the wire
fixture.
Remove all the screws
to disconnect the power
supply cables and the
connecting wires.
When reassembling, fasten
the wires with screws on the
terminal board.
3
Release the outdoor
temperature thermistor.
4
Lift up the protection
net and remove it.
5
Remove the 7 screws
and remove the right
side panel.
(R18666)
Wire fixture
Power
supply
cable
Connecting
wire
Terminal
board
(R12193)
Outdoor temperature thermistor
(R18894)
Protection
net
(R12217)
Right side panel