Si001277
Compressor
Removal Procedure
17
2
3
Disconnect the lead
wires of the
compressor.
Unfasten the hooks with
a flat screwdriver to
remove the overload
protector.
4
5
Remove the protection
bushing.
Remove the 2 nuts of
the compressor.
6
Heat up the brazed part
of the discharge side
and disconnect.
7
Heat up the brazed part
of the suction side and
disconnect.
8
Lift up the compressor
and remove it.
Step
Procedure
Points
(R18897)
Overload
protector
Red (U)
Yellow (V)
Blue
(W)
U
W
V
(R18673)
Protection bushing
Nut
(R18898)
Discharge
side
Suction side
(R8202)