8 Technical data

Installation manual

13

RXF50+60B2_RXF71A2_RXP50~71L2_(A)RXM42~71N2_RXJ50N2_
RXA42+50B2
R32 split series
3P512025-5E – 2018.05

8

Technical data

subset

  of  the  latest  technical  data  is  available  on  the  regional  Daikin  website  (publicly  accessible).  The 

full  set

  of  latest  technical  data  is

available on the Daikin extranet (authentication required).

8.1

Wiring diagram

The wiring diagram is delivered with the unit, located at the inside of the outdoor unit (bottom side of the top plate).

,

A

INDOOR

OUTDOOR

For applied parts and numbering, refer to the wiring diagram on the unit. Part numbering is by Arabic numbers in ascending order for each part 

and is represented in the overview below by symbol “*” in the part code.

Unified Wiring Diagram Legend

CIRCUIT BREAKER

: CONNECTION

: CONNECTOR

: EARTH

FIELD WIRING

: FUSE

INDOOR UNIT

OUTDOOR UNIT

PROTECTIVE EARTH

PROTECTIVE EARTH (SCREW)

: RECTIFIER

RELAY CONNECTOR

SHORT-CIRCUIT CONNECTOR

: TERMINAL

TERMINAL STRIP

WIRE CLAMP

WHT : WHITE
YLW : YELLOW

PNK 

: PINK

PRP, PPL :  PURPLE
RED  : RED

GRN : GREEN
GRY : GREY
ORG : ORANGE

BLK  : BLACK
BLU  : BLUE
BRN : BROWN

A*P 

PRINTED CIRCUIT BOARD

BS* 

PUSHBUTTON ON/OFF, OPERATION SWITCH

BZ, H*O 

BUZZER

C* 

: CAPACITOR

AC*, CN*, E*, HA*, HE*, HL*, HN*, : 

CONNECTION, CONNECTOR

HR*, MR*_A, MR*_B, S*, U, V,
W, X*A, K*R_*
D*, V*D 

DIODE

DB* 

DIODE BRIDGE

DS* 

DIP SWITCH

E*H 

: HEATER

F*U, FU* (FOR CHARACTERISTICS,  :  FUSE
REFER TO PCB INSIDE YOUR UNIT)
FG* 

CONNECTOR (FRAME GROUND)

H* 

: HARNESS

H*P, LED*, V*L 

PILOT LAMP, LIGHT EMITTING DIODE

HAP 

LIGHT EMITTING DIODE (SERVICE MONITOR GREEN)

HIGH VOLTAGE 

HIGH VOLTAGE

IES 

INTELLIGENT EYE SENSOR

IPM* 

INTELLIGENT POWER MODULE

K*R, KCR, KFR, KHuR, K*M 

MAGNETIC RELAY

: LIVE

L* 

: COIL

L*R 

: REACTOR

M* 

STEPPER MOTOR

M*C 

COMPRESSOR MOTOR

M*F 

FAN MOTOR

M*P 

DRAIN PUMP MOTOR

M*S 

SWING MOTOR

MR*, MRCW*, MRM*, MRN* 

MAGNETIC RELAY

: NEUTRAL

n=*, N=* 

NUMBER OF PASSES THROUGH FERRITE CORE

PAM 

PULSE-AMPLITUDE MODULATION

PCB* 

PRINTED CIRCUIT BOARD

PM* 

POWER MODULE

PS 

SWITCHING POWER SUPPLY

PTC* 

THERMISTOR PTC

Q* 

INSULATED GATE BIPOLAR TRANSISTOR 
(IGBT)

Q*DI 

EARTH LEAK CIRCUIT BREAKER

Q*L 

OVERLOAD PROTECTOR

Q*M 

THERMO SWITCH

R* 

: RESISTOR

R*T 

: THERMISTOR

RC 

: RECEIVER

S*C 

LIMIT SWITCH

S*L 

FLOAT SWITCH

S*NPH 

PRESSURE SENSOR (HIGH)

S*NPL 

PRESSURE SENSOR (LOW)

S*PH, HPS* 

PRESSURE SWITCH (HIGH)

S*PL 

PRESSURE SWITCH (LOW)

S*T 

: THERMOSTAT

S*RH 

HUMIDITY SENSOR

S*W, SW* 

OPERATION SWITCH

SA*, F1S 

SURGE ARRESTOR

SR*, WLU 

SIGNAL RECEIVER

SS* 

SELECTOR SWITCH

SHEET METAL  : 

TERMINAL STRIP FIXED PLATE

T*R 

: TRANSFORMER

TC, TRC 

TRANSMITTER

V*, R*V 

VARISTOR

V*R 

DIODE BRIDGE

WRC 

WIRELESS REMOTE CONTROLLER

X* 

: TERMINAL

X*M 

TERMINAL STRIP (BLOCK)

Y*E 

ELECTRONIC EXPANSION VALVE COIL

Y*R, Y*S 

REVERSING SOLENOID VALVE COIL

Z*C 

FERRITE CORE

ZF, Z*F 

NOISE FILTER

Summary of Contents for ARXM50N2V1B

Page 1: ...al R32 split series English Installation manual R32 split series RXF50B2V1B RXF60B2V1B RXF71A2V1B RXP50L2V1B RXP60L2V1B RXP71L2V1B ARXM50N2V1B RXM42N2V1B RXM50N2V1B RXM60N2V1B RXM71N2V1B RXJ50N2V1B RXA42B2V1B RXA50B2V1B ...

Page 2: ...in ne ovat muutettuina v platném znění Smjernice kako je izmijenjeno irányelv ek és módosításaik rendelkezéseit z późniejszymi poprawkami 18 19 20 21 22 23 24 25 Directivelor cu amendamentele respective Direktive z vsemi spremembami Direktiivid koos muudatustega Директиви с техните изменения Direktyvose su papildymais Direktīvās un to papildinājumos Smernice v platnom znení Değiştirilmiş halleriyl...

Page 3: ...n sallittu lämpötila TS TSmin Alhaisin matalapainepuolen lämpötila L C TSmax Suurinta sallittua painetta PS vastaava kyllästyslämpötila M C Kylmäaine N Varmuuspainelaitteen asetus P bar Valmistusnumero ja valmistusvuosi katso mallin nimikilpi Maximální přípustný tlak PS K bar Minimální maximální přípustná teplota TS TSmin Minimální teplota na nízkotlaké straně L C TSmax Saturovaná teplota odpovída...

Page 4: ...ellaisina kuin ne ovat muutettuina v platném znění Smjernice kako je izmijenjeno irányelv ek és módosításaik rendelkezéseit z późniejszymi poprawkami 18 19 20 21 22 23 24 25 Directivelor cu amendamentele respective Direktive z vsemi spremembami Direktiivid koos muudatustega Директиви с техните изменения Direktyvose su papildymais Direktīvās un to papildinājumos Smernice v platnom znení Değiştirilm...

Page 5: ...allittu lämpötila TS TSmin Alhaisin matalapainepuolen lämpötila L C TSmax Suurinta sallittua painetta PS vastaava kyllästyslämpötila M C Kylmäaine N Varmuuspainelaitteen asetus P bar Valmistusnumero ja valmistusvuosi katso mallin nimikilpi Maximální přípustný tlak PS K bar Minimální maximální přípustná teplota TS TSmin Minimální teplota na nízkotlaké straně L C TSmax Saturovaná teplota odpovídajíc...

Page 6: ... 1 Piping diagram Outdoor unit 14 1 About the documentation 1 1 About this document INFORMATION Make sure that the user has the printed documentation and ask him her to keep it for future reference Target audience Authorised installers Documentation set This document is part of a documentation set The complete set consists of General safety precautions Safety instructions that you MUST read before...

Page 7: ...e pipe length 3 m Maximum allowable height distance 20 m 4 Installation 4 1 Mounting the outdoor unit 4 1 1 To provide the installation structure Use a vibration proof rubber field supply in cases where vibrations may be transmitted to the building Prepare 4 sets of M8 or M10 anchor bolts nuts and washers field supply 20 mm 353 6 0 0 2 4 0 mm 2 4 0 300 In any case provide at least 300 mm of free s...

Page 8: ...vice port 2 Connect the gas refrigerant connection from the indoor unit to the gas stop valve of the outdoor unit NOTICE It is recommended that the refrigerant piping between indoor and outdoor unit is installed in a ducting or the refrigerant piping is wrapped with finishing tape 4 3 Checking the refrigerant piping 4 3 1 To check for leaks NOTICE Do NOT exceed the unit s maximum working pressure ...

Page 9: ... to the inside of the outdoor unit 4 4 2 About the refrigerant This product contains fluorinated greenhouse gases Do NOT vent gases into the atmosphere Refrigerant type R32 Global warming potential GWP value 675 WARNING FLAMMABLE MATERIAL The refrigerant inside this unit is mildly flammable WARNING The appliance shall be stored in a room without continuously operating ignition sources example open...

Page 10: ...aker with at least 3 mm between the contact point gaps that provide full disconnection under overvoltage category III WARNING If the supply cord is damaged it MUST be replaced by the manufacturer its service agent or similarly qualified persons in order to avoid a hazard WARNING Do NOT connect the power supply to the indoor unit This could result in electrical shock or fire WARNING Do NOT use loca...

Page 11: ...y installed protection devices are installed according to this document and have NOT been bypassed The power supply voltage matches the voltage on the identification label of the unit There are NO loose connections or damaged electrical components in the switch box There are NO damaged components or squeezed pipes on the inside of the indoor and outdoor units There are NO refrigerant leaks The ref...

Page 12: ...s If the LED is ON again the outdoor unit PCB is faulty OFF 1 Supply voltage for power saving 2 Power supply fault 3 Turn the power OFF and back ON and check the LED within approximately 3 minutes If the LED is ON again the outdoor unit PCB is faulty DANGER RISK OF ELECTROCUTION When the unit is not operating the LEDs on the PCB are turned off in order to save power Even when the LEDs are off the ...

Page 13: ...R MR _A MR _B S U V W X A K R_ D V D DIODE DB DIODE BRIDGE DS DIP SWITCH E H HEATER F U FU FOR CHARACTERISTICS FUSE REFER TO PCB INSIDE YOUR UNIT FG CONNECTOR FRAME GROUND H HARNESS H P LED V L PILOT LAMP LIGHT EMITTING DIODE HAP LIGHT EMITTING DIODE SERVICE MONITOR GREEN HIGH VOLTAGE HIGH VOLTAGE IES INTELLIGENT EYE SENSOR IPM INTELLIGENT POWER MODULE K R KCR KFR KHuR K M MAGNETIC RELAY L LIVE L ...

Page 14: ...or temperature Thermistor Refrigerant flow Cooling Heating PED categories of equipment High pressure switch category IV Compressor category II Other equipment art 4 3 Applicable for RXP60L RXP71L RXF60B RXF71A M HPS High pressure switch Automatic reset Heat exchanger 7 0 CuT 7 0 CuT 7 0 CuT 7 0 CuT 7 0 CuT 7 0 CuT 12 7 CuT 12 7 CuT 12 7 CuT 12 7 CuT 12 7 CuT 12 7 CuT 9 5 CuT 6 4 CuT 9 5 CuT 6 4 Cu...

Page 15: ...set Automatic reset High pressure switch Muffler PED categories of equipment High pressure switch category IV Compressor category II Other equipment art 4 3 Applicable for RXM42N RXM50N RXM60N ARXM50N RXJ50N RXA42B RXA50B M HPS High pressure switch Automatic reset Heat exchanger 7 0 CuT 7 0 CuT 7 0 CuT 7 0 CuT 7 0 CuT 7 0 CuT 12 7 CuT 12 7 CuT 12 7 CuT 12 7 CuT 12 7 CuT 12 7 CuT 6 4 CuT 9 5 CuT 6 4...

Page 16: ...3P512025 5E 2018 05 Copyright 2018 Daikin ...

Reviews: