SiBE04-809
Service Diagnosis
71
Part 6
Service Diagnosis
1. Caution for Diagnosis............................................................................72
2. Problem Symptoms and Measures .......................................................73
3. Service Check Function ........................................................................74
4. Troubleshooting ....................................................................................77
Error Codes and Description ..................................................................77
Indoor Unit PCB Abnormality .................................................................78
Freeze-up Protection Control or High Pressure Control.........................79
Fan Motor (DC Motor) or Related Abnormality.......................................81
Thermistor or Related Abnormality (Indoor Unit)....................................83
Front Panel Open / Close Fault..............................................................84
Signal Transmission Error (between Indoor and Outdoor Unit) .............85
Unspecified Voltage (between Indoor and Outdoor Units) .....................87
4.10 Outdoor Unit PCB Abnormality...............................................................88
4.11 OL Activation (Compressor Overload) ...................................................89
4.12 Compressor Lock ...................................................................................90
4.13 DC Fan Lock ..........................................................................................91
4.14 Input Over Current Detection .................................................................92
4.15 Four Way Valve Abnormality..................................................................93
4.16 Discharge Pipe Temperature Control.....................................................95
4.17 High Pressure Control in Cooling ...........................................................97
4.18 Compressor System Sensor Abnormality ..............................................99
4.19 Position Sensor Abnormality ................................................................100
4.20 DC Voltage / Current Sensor Abnormality............................................102
4.21 Thermistor or Related Abnormality (Outdoor Unit)...............................103
4.22 Electrical Box Temperature Rise..........................................................105
4.23 Radiation Fin Temperature Rise ..........................................................107
4.24 Output Over Current Detection.............................................................109
4.25 Insufficient Gas.....................................................................................111
4.26 Low-voltage Detection or Over-voltage Detection................................113
4.27 Signal Transmission Error on Outdoor Unit PCB .................................115
Summary of Contents for ARXG25E3V1B
Page 1: ...SiBE04 809 Applied Models Inverter Pair Heat Pump Inverter Pair Wall Mounted Type E Series ...
Page 11: ...Introduction SiBE04 809 x ...
Page 12: ...SiBE04 809 List of Functions 1 Part 1 List of Functions 1 List of Functions 2 ...
Page 14: ...SiBE04 809 Specifications 3 Part 2 Specifications 1 Specifications 4 ...