2
|
Components
Service manual
116
FTXF20~71A + FTXF20~25B + FTXF20~42C + ATXF20~71A + ATXF20~42C
+ RXF20~71A + RXF20~60B + RXF20~42C + ARXF20~71A + ARXF20~42C
Split Sensira R32
ESIE18-12E – 2021.02
a
b
c
a
Cover
b
Screw
c
Swing flap motor
2
Disconnect the connector from the swing flap motor.
3
Remove the screw from the swing flap motor.
4
Remove the swing flap motor from the swing flap.
5
To install the swing flap motor, see
115].
To install the swing flap motor
1
Install the swing flap motor in the correct location on the swing flap.
a
b
c
a
Cover
b
Screw
c
Swing flap motor
2
Install and tighten the screw to fix the swing flap motor.
3
Connect the connector to the swing flap motor.
4
Install the cover.
Is the problem solved?
Action
Yes
No further actions required.
No
Return to the troubleshooting of the
specific error and continue with the
next procedure.