Safety Precautions

• Read these Safety Precautions carefully to ensure correct installation. 
• This manual classifies the precautions into WARNING and CAUTION.

Be sure to follow all the precautions below: they are all important for ensuring safety. 

WARNING......... Failure to follow any of WARNING is likely to result in such grave consequences as death or serious injury. 

CAUTION......... Failure to follow any of CAUTION may result in grave consequences in some cases. 

• The following safety symbols are used throughout this manual: 

• After completing installation, test the unit to check for installation errors. Give the user adequate instructions 

concerning the use and cleaning of the unit according to the Operation Manual.

• The English text is the original instruction. Other languages are translations of the original instructions. 

Be sure to observe this instruction. 

Be sure to establish an earth connection. 

Never attempt. 

WARNING

• Installation should be left to the dealer or another professional. 

Improper installation may cause water leakage, electrical shock, or fire. 

• Install the air conditioner according to the instructions given in this manual. 

Incomplete installation may cause water leakage, electrical shock, or fire.

• Be sure to use the supplied or specified installation parts. 

Use of other parts may cause the unit to come to lose, water leakage, electrical shock, or fire. 

• Install the air conditioner on a solid base that can support the weight of the unit. 

An inadequate base or incomplete installation may cause injury in the event the unit falls off the base. 

• Electrical work should be carried out in accordance with the installation manual and the national electrical wiring 

rules or code of practice. 

Insufficient capacity or incomplete electrical work may cause electrical shock or fire.

• Be sure to use a dedicated power circuit. Never use a power supply shared by another appliance. 
• For wiring, use a cable length enough to cover the entire distance with no connection.

Do not use an extension cord. Do not put other loads on the power supply, use a dedicated power circuit. 

(Failure to do so may cause abnormal heat, electric shock or fire.)

• Use the specified types of wires for electrical connections between the indoor and outdoor units. 

Firmly clamp the interconnecting wires so their terminals receive no external stresses. Incomplete connections or clamping may cause terminal 
overheating or fire. 

• After connecting interconnecting and supply wiring be sure to shape the cables so that they do not put undue force 

on the electrical covers or panels.

Install covers over the wires. Incomplete cover installation may cause terminal overheating, electrical shock, or fire.

• If any refrigerant has leaked out during the installation work, ventilate the room. 

(The refrigerant produces a toxic gas if exposed to flames.) 

• After all installation is complete, check to make sure that no refrigerant is leaking out. 

(The refrigerant produces a toxic gas if exposed to flames.)

• When installing or relocating the system, be sure to keep the refrigerant circuit free from substances other than the 

specified refrigerant (R410A), such as air. 

(Any presence of air or other foreign substance in the refrigerant circuit causes an abnormal pressure rise or rupture, resulting in injury.)

• During pump-down, stop the compressor before removing the refrigerant piping. 

If the compressor is still running and the stop valve is open during pump-down, air will be sucked in when the refrigerant piping is removed,
causing abnormal pressure in the freezer cycle which will lead to breakage and even injury.

• During installation, attach the refrigerant piping securely before running the compressor. 

If the compressor is not attached and the stop valve is open during pump-down, air will be sucked in when the compressor is run, causing
abnormal pressure in the freezer cycle which will lead to breakage and even injury.

• Be sure to establish an earth. Do not earth the unit to a utility pipe, arrester, or telephone earth. 

Incomplete earth may cause electrical shock, or fire. A high surge current from lightning or other sources may cause damage to the 
air conditioner. 

• Be sure to install an earth leakage breaker. 

Failure to install an earth leakage breaker may result in electric shocks, or fire. 

CAUTION

• Do not install the air conditioner in a place where there is danger of exposure to inflammable gas leakage.

If the gas leaks and builds up around the unit, it may catch fire. 

• Establish drain piping according to the instructions of this manual. 

Inadequate piping may cause flooding. 

• Tighten the flare nut according to the specified method such as with a torque wrench. 

If the flare nut is tightened too hard, the flare nut may crack after a long time and cause refrigerant leakage. 

Summary of Contents for ARX25J3V1B

Page 1: ...INSTALLATION MANUAL R410A Split Series Models ARX20J3V1B ARX25J3V1B ARX35J3V1B ARX20K2V1B ARX25K2V1B ARX35K2V1B...

Page 2: ...06 95 EC Electromagnetic Compatibility 2004 108 EC 3P Takayuki Fujii Managing Director 1st of 1RY 201 IKIN TCF 0153 201 RX20J 9 RX25J V1B RX35J V1B 5 9 5 9 5 9 DEKRA NB0344 74736 KRQ EMC97 4957 U Nove...

Page 3: ...ado positivamente por B de acuerdo con el Certificado C 06 Nota delineato nel A e giudicato positivamente da B secondo il Certificato C 07 A B C 08 Nota tal como estabelecido em A e com o parecer posi...

Page 4: ...ng wires so their terminals receive no external stresses Incomplete connections or clamping may cause terminal overheating or fire After connecting interconnecting and supply wiring be sure to shape t...

Page 5: ...ich must be kept away from moisture NOTE Cannot be installed hanging from ceiling or stacked CAUTION When operating the air conditioner in a low outdoor ambient temperature be sure to follow the instr...

Page 6: ...onal refrigerant required for refrigerant pipe exceeding 10m in length Be sure to add the proper amount of additional refrigerant Failure to do so may result in reduced perfomance The suggested shorte...

Page 7: ...foundation surface Outdoor Unit Installation 1 Installing outdoor unit 1 When installing the outdoor unit refer to Precautions for Selecting the Location and the Outdoor Unit Installation Drawings 2 I...

Page 8: ...10A 3 Use torque wrenches when tightening the flare nuts to prevent damage to the flare nuts and gas leakage Align the centres of both flares and tighten the flare nuts 3 or 4 turns by hand Then tight...

Page 9: ...e of charging hose which comes from gauge manifold to gas stop valve s service port 2 Fully open gauge manifold s low pressure valve Lo and completely close its high pressure valve Hi High pressure va...

Page 10: ...id piping and to provide insulation dimensions as below 3 Use separate thermal insulation for gas and liquid refrigerant pipes Gas side Liquid side Gas pipe thermal insulation Liquid pipe thermal insu...

Page 11: ...force a test run to stop press the indoor unit operation stop button Using the main unit s remote controller 1 Press the operation stop button Operation will start 2 Press the temperature button and t...

Page 12: ...that the terminal numbers match Tighten the terminal screws securely We recommend a flathead screwdriver be used to tighten the screws The screws are packed with the terminal board Observe the notes...

Page 13: ...s OUTDOOR Outdoor CONDENSER Condenser DISCHARGE Discharge Strip wire end to this point Excessive strip length may cause electrical shock or leakage Good Wrong Stripping wire at terminal block C400 C40...

Page 14: ...t operation in accordance with the operation manual to ensure that all functions and parts such as louver movement are working properly The air conditioner requires a small amount of power in its stan...

Page 15: ......

Page 16: ...3P291651 10U 2014 10 Copyright 2014 Daikin...

Reviews: