V . Start-up (Readings must be taken at full load conditions)
A. Outdoor Fan Motor Amps:
T1 ______
Nameplate Rating: _______________
B. Compressor Amps (Cig):
T1 ______
T2 ______ T3 ______
Nameplate Rating: _______________
C. Compressor Amps (Htg):
T1______
T2 ______ T3 ______
Nameplate Rating: _______________
D. Refrigerant Pressures Htg./Clg.: Suction:_______ /_______ Discharge:_______ / _______
E. Refrigerant Temperature Htg./Clg.:
Suction_______°F/_______°F
Discharge:_______°F/_______°F
F. O.A.Temp.: __________°F
Super Heat: __________°F
Subcooling:_______°F
G. R.A. Temp. Htg./Clg.: ________°F/________°F Discharge Air Temp.:_______°F/_______°F
H. Electric Htg. Amp:
L1 ______
L2 ______
L3 ______ Total Amp: ____________
I. Water Temperature Htg./Clg.: In _______°F/_______°F
Out _______°F/_______°F
VI . Performed by:
Company:
_______________________________________________________________________________________________________
Name: __________________________________________________________________________________________________________
Title: ___________________________________________________________________________________________________________
Signature: _______________________________________________________________________________________________________
Date: ___________________________________________________________________________________________________________
Comments: __________________________________________________________________________________________________________
_________________________________________________________________________________________________________________
_________________________________________________________________________________________________________________
_________________________________________________________________________________________________________________
_________________________________________________________________________________________________________________
_________________________________________________________________________________________________________________
_________________________________________________________________________________________________________________
Service Technician: _____________________________________________________________________________________________________
Contractor Representative: _____________________________________________________________________________________________