![background image](http://html.mh-extra.com/html/daikin/arkc18rv2s/arkc18rv2s_service-manual_501297012.webp)
PCB
Si001413EB
10
Removal Procedure
4. PCB
Warning
Be sure to wait for 10 minutes or more after turning off all power supplies before
disassembling work.
Step
Procedure
Points
1
2
Remove the screw and
release the earth /
ground wire.
Pull out the 3 clamps.
3
4
Cut the clamp.
Pull out the terminals
from the terminal board.
Before pulling out the
terminals, confirm the
terminal locations.
(1): black (back)
(2): white (back)
(3): red (front)
Earth / ground screw
Clamp
Clamp
Clamp
(R20672)
Clamp
(R22020)
Clamp
(R20332)