9
|
Electrical installation
Installer reference guide
96
EBLA09~16DA + EDLA09~16DA
Daikin Altherma 3 M
4P620241-1 – 2020.06
Item
Description
WLAN cartridge
See:
▪
Installation manual of the WLAN cartridge
▪
Installer reference guide
—
[D]
Wireless gateway
Flow switch
See installation manual of the flow switch
Wires: 2×0.5 mm²
—
Location extra components
The following illustration shows the location of the extra components that you
need to install on the outdoor unit when using certain option kits.
e
d
a2
c
a1
b
f
OR
a
Accessories in standalone domestic hot water tank (EKHWS*D* and EKHWSU*D*)
a1: Contactor
a2: Terminal block
b
Connection kit for third‑party tank with built‑in thermostat (EKHY3PART2)
c
Flow switch (EKFLSW1)
d
Demand PCB (A8P: EKRP1AHTA)
e
Digital I/O PCB (A4P: EKRP1HBAA)
f
Smart grid relay kit (EKRELSG)
9.2.1 To connect the electrical wiring to the outdoor unit
1
2
Strip insulation (20 mm) from the wires.