Daikin ALTHERMA User Reference Manual Download Page 21

6 Maintenance and service

User reference guide

21

EGSQH10S18AA9W
Daikin Altherma ground source heat pump
4P351749-1D – 2016.09

6

Maintenance and service

6.1

Overview: Maintenance and
service

The installer has to perform a yearly maintenance. You can find the
contact/helpdesk number via the user interface.

As end user, you have to:

▪ Keep the area around the unit clean.

▪ Keep the user interface clean with a soft damp cloth. Do NOT use

any detergents.

▪ Regularly check if the water pressure indicated on the manometer

is above 1 bar.

Refrigerant

This  product  contains  fluorinated  greenhouse  gases.  Do  NOT  vent
gases into the atmosphere.

Refrigerant type: R410A

Global warming potential (GWP) value: 2087.5

NOTICE

In  Europe,  the 

greenhouse  gas  emissions

  of  the  total

refrigerant  charge  in  the  system  (expressed  as  tonnes
CO

2

-equivalent)  is  used  to  determine  the  maintenance

intervals. Follow the applicable legislation.

Formula  to  calculate  the  greenhouse  gas  emissions:

GWP value of the refrigerant × Total refrigerant charge [in
kg] / 1000

Please contact your installer for more information.

6.2

To find the contact/helpdesk
number

Prerequisite: 

You  switched  the  permission  level  to  Advanced  end

user.

1

Go  to  [6.3.2]: 

  >  Information  >  Error  handling  >  Contact/

helpdesk number.

7

Troubleshooting

7.1

Overview: Troubleshooting

If a malfunction occurs,   is displayed on the home pages. You can
press 

 to display more information about the malfunction.

For  the  symptoms  listed  below,  you  can  try  to  solve  the  problem
yourself. For any other problem, contact your installer. You can find
the contact/helpdesk number via the user interface.

7.2

To check the error history

Prerequisite: 

Only available if   is displayed on the home pages.

1

Go to [6.3.1]: 

 > Information > Error handling > Error history.

7.3

To check the warning history

Prerequisite: 

Only available if   is displayed on the home pages.

1

Go  to  [6.3.1]: 

  >  Information  >  Error  handling  >  Warning

history.

7.4

Symptom: You are feeling too cold
(hot) in your living room

Possible cause

Corrective action

The desired room temperature is
too low (high).

Increase (decrease) the desired
room temperature.

If the problem recurs daily, do
one of the following:

▪ Increase  (decrease)  the  room

temperature preset value.

▪ Adjust  the  room  temperature

schedule.

The desired room temperature
cannot be reached.

Increase the desired leaving
water temperature in accordance
with the heat emitter type.

7.5

Symptom: The water at the tap is
too cold

Possible cause

Corrective action

You ran out of domestic hot
water because of unusual high
consumption.

If you immediately need domestic
hot water, activate the DHW tank
booster mode. However, this
consumes extra energy.

If you can wait, overrule
(increase) the active or next
scheduled desired temperature
so that more hot water will be
produced exceptionally.

If the problems recurs daily, do
one of the following:

▪ Increase 

the 

DHW 

tank

temperature preset value.

▪ Adjust 

the 

DHW 

tank

temperature 

schedule.

Example: 

Program 

to

additionally 

heat 

up 

the

DHW  tank  to  a  preset  value
(Storage  eco  =  lower  tank
temperature) during the day.

The desired DHW tank
temperature is too low.

7.6

Symptom: Heat pump failure

When  the  heat  pump  fails  to  operate,  the  backup  heater  can  serve
as  an  emergency  heater  and  either  automatically  or  non-
automatically take over the heat load.

▪ When  auto  emergency  is 

activated

  and  a  heat  pump  failure

occurs,  the  backup  heater  will  automatically  take  over  the  heat
load.

▪ When  auto  emergency  is 

not  activated

  and  a  heat  pump  failure

occurs, the domestic hot water and space heating operations will
stop  and  need  to  be  recovered  manually.  The  user  interface  will
then ask you to confirm whether the backup heater can take over
the heat load or not.

When the heat pump fails,   will appear on the user interface.

Summary of Contents for ALTHERMA

Page 1: ...User reference guide Daikin Altherma ground source heat pump English User reference guide Daikin Altherma ground source heat pump EGSQH10S18AA9W...

Page 2: ...ing buttons and functions 15 4 7 Preset values and schedules 15 4 7 1 Using preset values 15 4 7 2 Using and programming schedules 16 4 7 3 Schedules Example 16 4 7 4 Predefined schedules Room tempera...

Page 3: ...e batteries may not be mixed with unsorted household waste If a chemical symbol is printed beneath the symbol this chemical symbol means that the battery contains a heavy metal above a certain concent...

Page 4: ...e Scheduled mode Scheduled reheat mode Part Description Advanced usage Information about Quiet mode Holiday mode Reading out information Date time units of measurement contrast and backlight User prof...

Page 5: ...l heat source is active Example Gas burner The disinfection mode is active A malfunction occured Press to display more information about the malfunction Weather dependent mode is active User permissio...

Page 6: ...in by the installer To determine which temperature control you are using method 2 If you have 2 user interfaces perform the following procedure on the user interface at the indoor unit Prerequisite Yo...

Page 7: ...u structure See also 4 4 6 Room thermostat control Using the leaving water temperature home pages on page 9 4 7 Preset values and schedules on page 15 4 4 5 Room thermostat control Using the room temp...

Page 8: ...emporarily overrule the schedule Desired temperature custom temperature 19 C At the next scheduled action 17 00 the schedule will be used again 17 00 18 0 C 17 20 20 0 C Scheduled Scheduled Mon Mon Yo...

Page 9: ...ng water temperature home page LWT main 2 Press or to adjust Example 35 C 37 C INFORMATION In case of weather dependency an offset value can be modified To adjust the leaving water temperature additio...

Page 10: ...ule To adjust the leaving water temperature main 1 Go to the main leaving water temperature home page LWT main 2 Press or to adjust Example 35 C 37 C To adjust the leaving water temperature additional...

Page 11: ...14 00 21 00 1 2 3 4 Tt Tt DHW tank temperature t Time INFORMATION When the DHW tank mode is reheat the risk for capacity shortage and comfort problem is significant In case of frequent reheat operatio...

Page 12: ...an do the following You can Location Do the same things as in scheduled mode Adjust the preset value Reheat Menu structure See also 4 5 3 Scheduled mode on page 11 4 7 Preset values and schedules on p...

Page 13: ...To set the user permission level to End user 1 Press for more than 4 seconds Result The user permission level switches to End user The user interface will return to the default home screen 4 6 2 Usin...

Page 14: ...Value Holiday mode Away From 2 February 2014 Until 16 February 2014 Operation mode Heating Heating 12 C 2 Activate the holiday mode Go to 2 1 Holiday Holiday Select Yes and press Advantage Before and...

Page 15: ...king and unlocking buttons and functions About locking and unlocking You can use the following locking modes Button lock Locks all buttons to prevent children from changing settings Function lock Lock...

Page 16: ...eating even if the desired temperature is not reached yet example if electric tariffs are higher during the day you can program a stop at 06 00 To select which schedule you currently want to use 1 Go...

Page 17: ...07 00 09 00 17 00 12 00 23 00 14 00 Sat Sun 08 00 23 00 Predefined 3 Mon Sun 08 00 23 00 4 7 6 Predefined schedules DHW tank temperature a Start production of domestic hot water Desired DHW tank tempe...

Page 18: ...ls or drops below the low ambient temperature Note in heating this value should be higher than d as for low outdoor temperatures warmer water is required d Desired leaving water temperature when the o...

Page 19: ...erface Indoor unit Outdoor unit User settings Display Temperature lock Set schedules Preset values Unit of measurement Display Contrast Backlit LCD time User profile Available home pages Set schedules...

Page 20: ...tips Tips about room temperature Make sure the desired room temperature is NEVER too high but ALWAYS according to your actual needs Each saved degree can save up to 6 of heating costs Do NOT increase...

Page 21: ...warning history Prerequisite Only available if is displayed on the home pages 1 Go to 6 3 1 Information Error handling Warning history 7 4 Symptom You are feeling too cold hot in your living room Pos...

Page 22: ...let of the heat pump Dealer Sales distributor for the product Authorized installer Technical skilled person who is qualified to install the product User Person who is owner of the product and or opera...

Page 23: ......

Page 24: ...4P351749 1D 2016 09 Copyright 2013 Daikin...

Reviews: