background image

4 Operation

User reference guide

13

EGSQH10S18AA9W
Daikin Altherma ground source heat pump
4P351749-1D – 2016.09

▪ You  do  NOT  have  to  activate  the  DHW  tank  booster  mode

(= energy saving).

4.5.6

Using the DHW tank booster mode

About the DHW tank booster mode

You  can  use  the  DHW  tank  booster  mode  to  immediately  start
heating up the water to the preset value (Storage comfort). However,
this consumes extra energy.

To check if the DHW tank booster mode is active

1

Go to the DHW tank temperature home page (Tank).

2

Check the following:

▪ In  user  profile  =  Basic:  If    is  displayed,  the  DHW  tank

booster mode is active.

▪ In  user  profile  =  Detailed:  If    is  selected,  the  DHW  tank

booster mode is active.

To activate the DHW tank booster mode (user profile = Basic)

1

Go to the DHW tank temperature home page (Tank).

2

Press 

 for more than 5 seconds.

To activate the DHW tank booster mode (user profile = Detailed)

1

Go to the DHW tank temperature home page (Tank).

2

Press 

 to select  .

Usage example: You immediately need more hot water

If you are in the following situation:

▪ You already consumed most of your hot water.

▪ You  cannot  wait  for  the  next  scheduled  action  to  heat  up  the

DHW tank.

Then you can activate the DHW tank booster mode.

Advantage:  The  DHW  tank  immediately  starts  heating  up  the  water
to the preset value (Storage comfort).

4.6

Advanced usage

4.6.1

About changing the user permission level

The  amount  of  information  you  can  read  out  in  the  menu  structure
depends on your user permission level:

▪ End user (= default)

▪ Adv. end user: You can read out more information.

To set the user permission level to Advanced end user

1

Go to the main menu or any of its submenus: 

.

2

Press 

 for more than 4 seconds.

Result: 

The  user  permission  level  switches  to  Adv.  end  user.

Additional information is displayed and "+" is added to the menu title.
The  user  permission  level  will  stay  in  Adv.  end  user  until  set
otherwise.

To set the user permission level to End user

1

Press 

 for more than 4 seconds.

Result: 

The  user  permission  level  switches  to  End  user.  The  user

interface will return to the default home screen.

4.6.2

Using quiet mode

INFORMATION

Quiet mode is NOT applicable for this unit.

4.6.3

Using holiday mode

About holiday mode

During  your  holiday,  you  can  use  the  holiday  mode  to  deviate  from
your normal schedules without having to change them. You can only
use  holiday  mode  if  temperature  control  =  room  thermostat  control.
See  also 

"4.4.3  Determining  which  temperature  control  you  are

using" on page 6

.

Using holiday mode typically consists of the following stages:

1

Configuring the holiday for one of the following situations:

Situation

Then…

You stay at home
during your holiday

You have to select a day: space
heating will be according to the desired
room temperature of the selected day.

You go away during
your holiday

You have to configure space heating
settings.

▪ Space  heating  will  be  according  to

these settings.

▪ Domestic  hot  water  operation  can

be turned ON or OFF. If you decide
to turn it OFF, disinfection mode will
remain active.

2

Activating the holiday mode.

▪ If  you  do  NOT  activate,  the  configured  holiday  settings  will

NOT be used.

▪ If you activate:

Period

Then…

Before and after your
holiday

Your normal schedules will be used.

During your holiday

The configured holiday settings will
be used.

To check if holiday mode is activated and/or running

1

Press 

 to go to one of the home pages.

2

Check the following:

If… is displayed

Then…

One of the following holiday
modes is activated:

▪ Holiday  mode  (Away)  is

activated,  but  NOT  running
yet.

▪ Holiday  mode  (Home)  is

activated.  You  cannot  see  if
the  holiday  mode  is  already
running.

15:20

12.0°C

16

2013

Holiday

Mon

Feb

Until
Actual temp.

Holiday mode (Away) is
activated and running.

To configure the holiday (when you stay at home)

Prerequisite: 

You  switched  the  permission  level  to  Advanced  end

user.

1

Go to [2.2]: 

 > Holiday > Holiday mode.

2

Select Home.

3

Configure the holiday mode settings (when you stay at home).

4

Activate the holiday mode.

Summary of Contents for ALTHERMA

Page 1: ...User reference guide Daikin Altherma ground source heat pump English User reference guide Daikin Altherma ground source heat pump EGSQH10S18AA9W...

Page 2: ...ing buttons and functions 15 4 7 Preset values and schedules 15 4 7 1 Using preset values 15 4 7 2 Using and programming schedules 16 4 7 3 Schedules Example 16 4 7 4 Predefined schedules Room tempera...

Page 3: ...e batteries may not be mixed with unsorted household waste If a chemical symbol is printed beneath the symbol this chemical symbol means that the battery contains a heavy metal above a certain concent...

Page 4: ...e Scheduled mode Scheduled reheat mode Part Description Advanced usage Information about Quiet mode Holiday mode Reading out information Date time units of measurement contrast and backlight User prof...

Page 5: ...l heat source is active Example Gas burner The disinfection mode is active A malfunction occured Press to display more information about the malfunction Weather dependent mode is active User permissio...

Page 6: ...in by the installer To determine which temperature control you are using method 2 If you have 2 user interfaces perform the following procedure on the user interface at the indoor unit Prerequisite Yo...

Page 7: ...u structure See also 4 4 6 Room thermostat control Using the leaving water temperature home pages on page 9 4 7 Preset values and schedules on page 15 4 4 5 Room thermostat control Using the room temp...

Page 8: ...emporarily overrule the schedule Desired temperature custom temperature 19 C At the next scheduled action 17 00 the schedule will be used again 17 00 18 0 C 17 20 20 0 C Scheduled Scheduled Mon Mon Yo...

Page 9: ...ng water temperature home page LWT main 2 Press or to adjust Example 35 C 37 C INFORMATION In case of weather dependency an offset value can be modified To adjust the leaving water temperature additio...

Page 10: ...ule To adjust the leaving water temperature main 1 Go to the main leaving water temperature home page LWT main 2 Press or to adjust Example 35 C 37 C To adjust the leaving water temperature additional...

Page 11: ...14 00 21 00 1 2 3 4 Tt Tt DHW tank temperature t Time INFORMATION When the DHW tank mode is reheat the risk for capacity shortage and comfort problem is significant In case of frequent reheat operatio...

Page 12: ...an do the following You can Location Do the same things as in scheduled mode Adjust the preset value Reheat Menu structure See also 4 5 3 Scheduled mode on page 11 4 7 Preset values and schedules on p...

Page 13: ...To set the user permission level to End user 1 Press for more than 4 seconds Result The user permission level switches to End user The user interface will return to the default home screen 4 6 2 Usin...

Page 14: ...Value Holiday mode Away From 2 February 2014 Until 16 February 2014 Operation mode Heating Heating 12 C 2 Activate the holiday mode Go to 2 1 Holiday Holiday Select Yes and press Advantage Before and...

Page 15: ...king and unlocking buttons and functions About locking and unlocking You can use the following locking modes Button lock Locks all buttons to prevent children from changing settings Function lock Lock...

Page 16: ...eating even if the desired temperature is not reached yet example if electric tariffs are higher during the day you can program a stop at 06 00 To select which schedule you currently want to use 1 Go...

Page 17: ...07 00 09 00 17 00 12 00 23 00 14 00 Sat Sun 08 00 23 00 Predefined 3 Mon Sun 08 00 23 00 4 7 6 Predefined schedules DHW tank temperature a Start production of domestic hot water Desired DHW tank tempe...

Page 18: ...ls or drops below the low ambient temperature Note in heating this value should be higher than d as for low outdoor temperatures warmer water is required d Desired leaving water temperature when the o...

Page 19: ...erface Indoor unit Outdoor unit User settings Display Temperature lock Set schedules Preset values Unit of measurement Display Contrast Backlit LCD time User profile Available home pages Set schedules...

Page 20: ...tips Tips about room temperature Make sure the desired room temperature is NEVER too high but ALWAYS according to your actual needs Each saved degree can save up to 6 of heating costs Do NOT increase...

Page 21: ...warning history Prerequisite Only available if is displayed on the home pages 1 Go to 6 3 1 Information Error handling Warning history 7 4 Symptom You are feeling too cold hot in your living room Pos...

Page 22: ...let of the heat pump Dealer Sales distributor for the product Authorized installer Technical skilled person who is qualified to install the product User Person who is owner of the product and or opera...

Page 23: ......

Page 24: ...4P351749 1D 2016 09 Copyright 2013 Daikin...

Reviews: