4
|
Operation
User reference guide
23
C08AF + EHYKOMB33AA
Daikin Altherma R Hybrid
4P471762-1B – 2020.10
4.5.1 About domestic hot water control
Your system layout may or may not contain a domestic hot water tank. When no
tank is installed, the boiler provides domestic hot water instantly. When, on the
contrary, a tank is installed, domestic hot water control is different depending on
the DHW tank mode set by the installer:
▪
Reheat mode
▪
Scheduled mode
▪
Sch reheat mode
4.5.2 Instant DHW (no tank installed)
Not applicable for Switzerland
When there is a demand for hot water tapping, the boiler provides DHW instantly.
Using the instant DHW home page
Not applicable for Switzerland
Depending on the user profile, the user interface gives you either a basic or a
detailed home page.
User profile =
Basic
User profile =
Detailed
44°C
01:03
Tue
DHW
Desired temperature
01:03
44°C
Tue
DHW
Desired temperature
To adjust the instant DHW temperature
1
Go to the instant DHW home page.
2
Press or to adjust the instant DHW temperature (
DHW
).
The instant DHW set point temperature may NOT be below 40°C.
4.5.3 Tank
The following modes are only applicable if a tank is installed and are set by the
installer.
To determine which DHW tank mode you are using (method 1)
Check the installer settings table filled in by the installer.
To determine which DHW tank mode you are using (method 2)
Prerequisite:
User profile =
Detailed
.
1
Go to the DHW tank temperature home page (
Tank
).
2
Check which icons are displayed:
If… is displayed
Then the DHW tank mode =…
Reheat mode
Scheduled mode
Sch reheat mode