9 Technical data

Installation manual

18

ERRA08~12E

Daikin Altherma 3 R MT

4P708481-1 – 2023.02

H1P~H7P (A1P)

Light-emitting diode (service monitor is
orange)

HAP (A1P)

Light-emitting diode (service monitor is
green)

K1R (A1P)

Magnetic relay (Y1S)

K2R (A1P)

Magnetic relay (Y2S)

K3R (A1P)

Magnetic relay (Y3S)

K4R (A1P)

Magnetic relay (Y4S)

K10R (A1P)

Magnetic relay

K11M (A1P)

Magnetic contactor

K13R~K15R (A1P,
A2P)

Magnetic relay

L1R~L3R (A1P)

Reactor

M1C

Compressor motor

M1F

Fan motor

PS (A1P)

Switching power supply

Q1DI

Earth leakage circuit breaker (30 mA) (field
supply)

R1~R5 (A1P, A2P)

Resistor

R1T

Thermistor (outdoor air)

R2T

Thermistor (compressor discharge)

R3T

Thermistor (compressor suction)

R4T

Thermistor (air heat exchanger, liquid pipe)

R5T

Thermistor (air heat exchanger, middle)

R7T

Thermistor (injection)

R11T

Thermistor (fin)

RC (A2P)

Signal receiver circuit

S1NPH

High pressure sensor

S1PH, S2PH

High pressure switch

S1PL

Low pressure switch

TC (A2P)

Signal transmission circuit

V1D~V4D (A1P)

Diode

V1R (A1P)

IGBT power module

V2R (A1P)

Diode module

V1T~V3T (A1P)

Insulated Gate Bipolar Transistor (IGBT)

X1M

Terminal strip

Y1E

Electronic expansion valve (main)

Y3E

Electronic expansion valve (injection)

Y1S

Solenoid valve (4‑way valve)

Y2S

Solenoid valve (low pressure bypass)

Y3S

Solenoid valve (hot gas bypass)

Y4S

Solenoid valve (liquid injection)

Z1C~Z11C

Noise filter (ferrite core)

Z1F~Z6F (A1P, A2P)

Noise filter

Summary of Contents for Altherma ERRA08E V3 Series

Page 1: ...tion manual Daikin Altherma 3 R MT English Installation manual Daikin Altherma 3 R MT ERRA08E V3 ERRA10E V3 ERRA12E V3 ERRA08E W1 ERRA10E W1 ERRA12E W1 1 2 3 9 A B C Z 1 2 3 9 https daikintechnicaldat...

Page 2: ...1...

Page 3: ...t Paper in the box of the indoor unit Operation manual Quick guide for basic usage Format Paper in the box of the indoor unit User reference guide Detailed step by step instructions and background inf...

Page 4: ...nual See 5 Piping installation 48 DANGER RISK OF BURNING SCALDING WARNING Provide adequate measures to prevent that the unit can be used as a shelter by small animals Small animals that make contact w...

Page 5: ...tdoor unit a O ring for drain socket b Drain socket c Thermistor fixture for installations in areas with low ambient temperatures d Compressor cover piece e Declaration of conformity f Installation ma...

Page 6: ...Pedestal When installing on a pedestal make sure that the discharge grille still can be put in its safety position See 7 4 To remove the discharge grille and put the grille in safety position 414 8 0...

Page 7: ...w the unit Additionally make sure the unit is positioned at least 100 mm above the expected level of snow Use the drain plug with O ring for drainage 1 2 a b c a Drain hole b O ring delivered as acces...

Page 8: ...NGER RISK OF BURNING SCALDING NOTICE Vibration To prevent vibration of the refrigerant piping during operation fixate the piping between the outdoor and indoor unit NOTICE Vibration To prevent vibrati...

Page 9: ...gets cold Soap water contains ammonia which may lead to corrosion of flared joints between the brass flare nut and the copper flare 1 Charge the system with nitrogen gas up to a gauge pressure of at l...

Page 10: ...label on the inside of the outdoor unit There is a dedicated place for it on the wiring diagram label 6 Electrical installation DANGER RISK OF ELECTROCUTION WARNING Rotating fan Before powering ON or...

Page 11: ...a1 a2 Power supply cable field supply b1 b2 Interconnection cable field supply c1 c2 No use d Cable sleeves factory mounted 3 Inside the switch box connect the wires to the appropriate terminals and f...

Page 12: ...Route the cable through the frame Connect the wires to the terminal block Fix the cable with a cable tie Wires 3N GND Maximum running current Refer to name plate on unit 3N 50 Hz 400 V AC b a Q1DI L1...

Page 13: ...e outdoor unit installation 7 1 Insulate and fix the refrigerant piping and cable 1 Insulate and fix the refrigerant piping and cables as follows g b a f e c d a Gas pipe b Gas pipe insulation c Inter...

Page 14: ...sly to the lower part to prevent vibrations 4 Align and attach the left side 5 Align and attach the middle part 6 Align and attach the right side 5 4 6 7 Insert the hooks 8 Insert the ball studs 8 7 9...

Page 15: ...nterparts on the unit 5 Insert the hook 6 Insert the ball stud 6 5 8 Starting up the outdoor unit See the indoor unit installation manual for configuration and commissioning of the system WARNING Rota...

Page 16: ...sor suction c Gas stop valve with service port R4T Thermistor air heat exchanger distributor d Liquid stop valve R5T Thermistor air heat exchanger middle e Pinched pipe R7T Thermistor injection f Refr...

Page 17: ...ly F1U F4U A2P Fuse T 6 3 A 250 V F5U A1P Fuse T 5 0 A 250 V HAP A1P Light emitting diode service monitor is green K1R A1P Magnetic relay Y1S K2R A1P Magnetic relay Y2S K3R A1P Magnetic relay Y3S K4R...

Page 18: ...utdoor air R2T Thermistor compressor discharge R3T Thermistor compressor suction R4T Thermistor air heat exchanger liquid pipe R5T Thermistor air heat exchanger middle R7T Thermistor injection R11T Th...

Page 19: ......

Page 20: ...4P708481 1 2023 02 Copyright 2023 Daikin 4P708481 1 0000000Q Verantwortung f r Energie und Umwelt...

Reviews: