EK EK80ABV1

 

Daikin Altherma indoor unit

 

4P404418-1 – 2015.04

 

Operation manual

 

4

 

11.

 

TEMPERATURE DISPLAY 

 

The display shows the current temperature of the installation
either leaving water set point temperature or actual room
temperature.
When changing the room temperature set point, the set point will
be flashing for 5 seconds and then return to the actual room
temperature.

 

12.

 

SETTING 

 

When you enter field setting in the field setting mode, this will be
indicated. See 

"4.14. Operating the optional remote controller"

on page 18

.

 

13.

 

NOT AVAILABLE 

 

This icon is displayed whenever a non-installed option is
addressed or a function is not available. A function not available
can mean insufficient permission level or can mean that a slave
remote controller is used (see installation manual).

 

14. DEFROST/START UP MODE ICON 

This icon indicates that the defrost/start up mode is active.

15. COMPRESSOR ICON 

This icon indicates that the compressor in the indoor unit of the
installation is active.

16. HEATER STEP 

If the heater kit option is installed, 

 icon indicate that the heater

is operating.

17. PUMP ICON 

This icon indicates that the heating/cooling circulation pump is
active.

18. OUTDOOR TEMPERATURE DISPLAY 

When this icon is flashing, the outdoor ambient temperature is
displayed. Refer to 

"4.10. 

Temperature read-out mode" on

page 10

 for more information.

19. WEATHER DEPENDENT SET POINT ICON 

This icon indicates that the controller will adapt the leaving water
temperature set point automatically, based on the outdoor
ambient temperature.

20. TEMPERATURE ICON 

This icon is displayed when the actual room temperature or
room temperature set point are shown.
The icon is also displayed when the temperature set point is set
in schedule timer programming mode. Refer to

"4.10. 

Temperature read-out mode" on page 

10

 for more

information.

21. TEST OPERATION ICON 

This icon indicates that the unit runs in test mode.

22. FIELD SET CODE 

This code represents the code from the field set list. Refer to the

"4.16. Field settings table" on page 20

.

23. ERROR CODE 

This code refers to the error code list and is for service purposes
only. Refer to the error code list in the installation manual.

24. DOMESTIC WATER HEATING BUTTON 

This button enables or disables the different domestic hot water
modes in combination with the schedule timer button.
This button is not used when the domestic hot water tank is not
installed.

25. WEATHER DEPENDENT SET POINT BUTTON 

This button enables or disables the weather dependent set point
function which is available in space heating operation.
If the controller is set to permission level 3 (refer to "Field
settings" in the installation manual), the weather dependent set
point button will not be operable.

26. INSPECTION/TEST OPERATION BUTTON 

This button is used for installation purposes and changing field
settings. Refer to 

"4.15. Field settings" on page 19

.

27. PROGRAMMING BUTTON 

This multi-purpose button is used to program the controller. The
function of the button depends on the actual status of the
controller or on previous actions carried out by the operator.

28. SCHEDULE TIMER BUTTON 

/

The main function of this multi-purpose button is to enable/
disable the schedule timer.
The button is also used to set the clock and to program the
controller. The function of the button depends on the actual
status of the controller or on previous actions carried out by the
operator.

29. TIME ADJUST BUTTONS 

 and 

These multi-purpose buttons are used to adjust the clock, to
toggle between temperatures (water inlet/outlet temperature of
the indoor unit, outdoor ambient temperature, actual room
temperature and domestic hot water temperature) and in
schedule timer programming mode.

30. LEAVING WATER TEMPERATURE ADJUST BUTTONS

 and 

These buttons are used to adjust the leaving water temperature
set point in normal operation mode or in schedule timer
programming mode.
If the controller is set to permission level 3 (refer to "Field
settings" in the installation manual), the leaving water
temperature adjust button will not be operable.
In case the weather dependent set point operation is selected,
the unit has a floating set point. In this case, the 

 icon as well

as the shift value (in case not zero) will display.

31. ROOM TEMPERATURE ADJUST BUTTONS 

 and 

These multi-purpose buttons are used to adjust the current room
temperature set point in normal operation mode or in schedule
timer programming mode.
When changing the room temperature set point, the set point
value on the display will be flashing. After 5 seconds the display
will show to the actual room temperature.

32. QUIET MODE BUTTON 

This button enables or disables quiet mode.
If the controller is set to permission level 2 or 3 (refer to "Field
settings" in the installation manual), the quiet mode button will
not be operable.

33. The 

 button is used to select the operation mode: space

heating ( ) or space cooling ( ).

Master

Slave

Permission

level 2

level 3

Operation ON/OFF

Domestic water heating operation ON/
OFF

Setting the leaving water temperature

Setting the room temperature

Quiet mode ON/OFF

Weather dependent set point operation 
ON/OFF

Setting the clock

Programming the schedule timer

Schedule timer operation ON/OFF

Field settings

Error code display

Test operation

 = operable

NOTE

Remark that pushing the 

 button has no

influence on the domestic water heating.
Domestic water heating is only switched on or off
by means of the 

 button and/or disabling the

storage schedule timer.

Summary of Contents for Altherma EKHVMRD50ABV1

Page 1: ...OPERATION MANUAL EKHVMRD50ABV1 EKHVMRD80ABV1 EKHVMYD50ABV1 EKHVMYD80ABV1 Daikin Altherma indoor unit ...

Page 2: ...wledge unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety Children shall be supervised to ensure that they do not play with the appliance 1 DEFINITIONS Installation manual Instruction manual specified for a certain product or application explaining how to install configure and maintain it Danger Indicates an imminently ha...

Page 3: ...g The more detailed information of how the unit must be operated is explained in the chapter 4 Operation of the unit on page 3 The quick start up offers the user the possibility to start up the system before reading the entire manual Space heating operation NOTE An EKHVMRD and EKHVMYD indoor unit can only be connected to an EMRQ outdoor unit The installation of the indoor unit s is described in th...

Page 4: ...eating only if domestic hot water tank option is installed Automatic storage daily water heat up once during night and or once during day Turn on field setting 1 00 and or 1 02 and then push the button See Automatic storage on page 8 The icon will display Hot water will be produced at next scheduled action When water heat up starts the icon will be blinking 1 second interval Manual storage one tim...

Page 5: ...r to Field settings in the installation manual the weather dependent set point button will not be operable 26 INSPECTION TEST OPERATION BUTTON This button is used for installation purposes and changing field settings Refer to 4 15 Field settings on page 19 27 PROGRAMMING BUTTON This multi purpose button is used to program the controller The function of the button depends on the actual status of th...

Page 6: ...aving water temperature which you want to be used to heat up your system for detailed information see Leaving water temperature control on page 6 Automatic setback function Setback function provides the possibility to lower the room temperature The setback function can for instance be activated during the night because the temperature demands during night and day are not the same The setback funct...

Page 7: ...al room thermostat 1 Press the button 1 time to select weather dependent set point operation or 2 times when the remote controller room thermostat function is used Icon appears on the display as well as the shift value The shift value is not shown in case it is 0 2 Use the and buttons to set the shift value Range for the shift value 5 C to 5 C Icon will be displayed as long as the weather dependen...

Page 8: ...edule timer function 3 Use the and buttons to select the leaving water temperature which you want to be used to cool down your system for detailed information see Leaving water temperature control on page 6 Leaving water temperature control In this mode cooling will be activated as required by the water temperature set point The set point can be set manually or through the schedule timer Selecting...

Page 9: ...Therefore it is recommended to use this function b 04 Automatic maximum domestic hot water storage temperature default 70 C NOTE Any domestic water heating operation is impossible when the domestic hot water tank is not installed A Storage operation if activated B Reheat operation if activated C Disinfection operation if activated Field settings D Disinfection operation temperature 5 00 e g 70 C E...

Page 10: ...estic water heating modes on page 8 Disinfection operation This mode will disinfect the domestic hot water tank by periodically heating the domestic water to a specific temperature During the operation of this mode the icon will be blinking rapidly with 0 5 second intervals The disinfection temperature set point is a field setting as are the retention time day and hour Refer to 4 15 Field settings...

Page 11: ...t possible If you are using the remote controller room temperature control When the reheat temperature is reached the further heat up of the domestic hot water tank will be decided by the remote controller room thermostat in order to prevent the room temperature to drop too much If you are using the external room thermostat When the reheat temperature is reached the further heat up of the domestic...

Page 12: ...stays enabled When pushing the button The schedule timer for space heating and domestic water heating along with the quiet mode will be stopped and will not start again The schedule timer icon will not be displayed anymore 1 Schedule timer 2 Setback function 3 When both setback function and schedule timer are enabled A Setback function t Time T Temperature set point Room temperature Leaving water ...

Page 13: ...n can be used Reheat the reheat function can be activated next to or separate from the automatic storage operation if the user wants to keep the domestic hot water tank at the minimum reheat temperature Next to the standard domestic water heating operation modes it is also possible to freely program the domestic water heating operation through the schedule timer refer to Programming domestic water...

Page 14: ...programmed for the same day and at the same time only the action with the highest action number will be executed Example You can always alter add or remove the programmed actions later NOTE If the auto restart function is disabled the schedule timer will not be activated when power returns to the unit after a power supply failure Press the button to enable the schedule timer again When power retur...

Page 15: ...ature 10 Use the and buttons to set the room temperature 11 Use the button to select to switch heating and the remote controller off to select automatic temperature calculation for leaving water temperature Use the and buttons to set the appropriate shift value refer to 4 3 Space heating operation on page 5 for more information about weather dependent set point 12 Repeat steps 7 to 11 to program t...

Page 16: ...ime 8 Use the and buttons to set the leaving water temperature 9 Use the and buttons to set the room temperature 10 Use the button to select to switch cooling and the remote controller off 11 Repeat steps 6 to 10 to program the other actions When all actions have been programmed make sure that the display shows the highest action number you would like to save 12 Press the button for 5 seconds to s...

Page 17: ...ppears 7 Use the button to select the action number you would like to program or to modify 8 Use the and buttons to set the correct action time 9 Use the button to select or deselect as action 10 Repeat steps 7 to 9 to program the other actions of the selected mode When all actions have been programmed make sure that the display shows the highest action number you would like to save 11 Press the b...

Page 18: ... program or to modify 7 Use the and buttons to set the correct action time 8 Use the button to select or deselect as action 9 Repeat steps 6 to 8 to program the other actions of the selected mode When all actions have been programmed make sure that the display shows the highest action number you would like to save 10 Press the button for 5 seconds to store the programmed actions If the button is p...

Page 19: ...copied You can return to step 2 by pressing the button Deleting one or more programmed actions Deleting one or more programmed actions is done at the same time as storing the programmed actions When all actions for one day have been programmed make sure that the display shows the highest action number you would like to save By pressing the button for 5 seconds you store all actions except those wi...

Page 20: ...on 3 will be displayed The current selected field setting code is indicated 2 with the set value displayed to the right 1 2 Press the button to select the appropriate field setting first code 3 Press the button to select the appropriate field setting second code 4 Press the button and button to change the set value of the select field setting 5 Save the new value by pressing the button 6 Repeat st...

Page 21: ...eather dependent set point 00 Low ambient temperature Lo_A 10 20 5 1 C 01 High ambient temperature Hi_A 15 10 20 1 C 02 Set point at low ambient temperature Lo_Ti 70 25 80 1 C 03 Set point at high ambient temperature Hi_Ti 45 25 80 1 C 4 Disinfection function 00 Status disinfection operation 1 ON 0 1 01 Disinfection operation day selection Fri Mon Sun 02 Disinfection operation start time 23 00 0 0...

Page 22: ...ture limits 00 Installation related setting a 80 37 80 1 C 01 Installation related setting a 25 25 37 1 C 02 Installation related setting a 20 18 22 1 C 03 Installation related setting a 5 5 18 1 C 04 Not applicable Do not change the default value 0 d Domestic water heating retention times 00 Installation related setting a 10 5 20 1 01 Installation related setting a 30 10 60 5 02 Installation rela...

Page 23: ...o not try to dismantle the system yourself the dismantling of the system treatment of the refrigerant of oil and other parts must be done by a qualified installer in accordance with the applicable legislation Units must be treated at a specialized treatment facility for re use recycling and recovery By ensuring this product is disposed off correctly you will help to prevent potential negative cons...

Page 24: ...NOTES ...

Page 25: ...NOTES ...

Page 26: ...NOTES ...

Page 27: ......

Page 28: ...4P404418 1 2015 04 Copyright 2015 Daikin ...

Reviews: