as electricity. The primary energy factor for natural gas is 1.
Assuming an average electricity production efficiency (including
transportation losses) of 40%, the primary energy factor for
electricity equals 2.5 (=1/0.40). The primary energy factor allows you
to compare 2 different energy sources. In this case, the primary
energy use of the heat pump is compared to the natural gas use of
the gas boiler.
#
Code
Description
N/A
[7‑03]
Compares the primary energy use of the
heat pump with that of the boiler.
Range: 0~6
INFORMATION
▪ The primary energy factor can always be set, but is
only used in case the savings mode is set to
Ecological.
▪ To set electricity price values, do NOT use overview
settings. Set them in the menu structure instead
([7.4.5.1], [7.4.5.2], and [7.4.5.3]). For more information
on how to set the energy prices, see the operation
manual and the user reference guide.
INFORMATION
Solar panels.
If solar panels are used, set the electricity
price value very low to promote the use of the heat pump.
6.2.4
Quick wizard: Capacities (energy
metering)
#
Code
Description
[A.2.3.6]
[6-07]
Bottom plate heater capacity [W]
6.2.5
Space heating control
Leaving water temperature: Main zone
#
Code
Description
[A.3.1.1.1]
N/A
Set point mode:
▪ 0 (Fixed): Absolute
▪ 1
(Weather
dep.):
Weather-
dependent
▪ 2 (Fixed/scheduled): Absolute +
scheduled (only for leaving water
temperature control)
▪ 3
(WD/scheduled):
Weather-
dependent + scheduled (only for
leaving water temperature control)
[7.7.1.1]
[1‑00]
[1‑01]
[1‑02]
[1‑03]
Weather-dependent curve (heating):
[1-03]
[1-02]
Ta
Tt
[1-00]
[1-01]
▪ T
t
: Target leaving water temperature
(main)
▪ T
a
: Outdoor temperature
INFORMATION
In order to optimise comfort as well as running costs, it is
recommended to choose weather-dependent setpoint
operation. Set the settings carefully; they have significant
influence on heat pump as well as boiler operation. Too
high leaving water temperature can result in constant boiler
operation.
Pump control
*HY32AA gas boiler
Third-party gas boiler
a
a
Main pump (= inside the gas
boiler)
a
a
Main pump (= external pump)
If...
Then the main pump runs...
Space heating is done
by...
And...
Outdoor unit only
[C-0B]=1 According to ΔT control (see
below).
[C-0B]=0 At maximum pump speed.
Gas boiler only
(only applicable in case of
*HY32AA gas boiler)
At maximum pump speed.
Combination of outdoor unit and
gas boiler
(only applicable in case of
*HY32AA gas boiler)
If the pump runs according to ΔT control:
If Emitter type [2-0C]=...
Then the target ΔT in heating
is...
0: Underfloor heating
Variable according to [1-0B].
1: Fancoil unit
2: Radiator
Fixed (10°C).
INFORMATION
Changing these settings can result in discomfort. Refer to
the installer reference guide for more information.
Leaving water temperature: Modulation
#
Code
Description
[A.3.1.1.5]
[8‑05]
Leaving water temperature modulation:
▪ 0 (No): Disabled
▪ 1 (Yes): Enabled. The leaving water
temperature is calculated according
to the difference between desired
and actual room temperature. This
allows
better
matching
of
the
heat
pump
capacity
to
actual
required capacity and results in less
start/stop cycles of the heat pump
and more economic operation.