background image

2 User safety instructions

Operation manual

3

EA23DA6V(7)+9W
Daikin Altherma 3 H F
4P556074-1A – 2021.09

3

Turn the left dial and go to 

Operation range

.

Operation range

4.3

4

Press the left dial to enter the submenu.

2

User safety instructions

Always observe the following safety instructions and regulations.

2.1

General

WARNING

If you are NOT sure how to operate the
unit, contact your installer.

WARNING

This appliance can be used by children
aged from 8 years and above and
persons with reduced physical, sensory
or mental capabilities or lack of
experience and knowledge if they have
been given supervision or instruction
concerning use of the appliance in a
safe way and understand the hazards
involved.

Children SHALL NOT play with the
appliance.

Cleaning and user maintenance
SHALL NOT be made by children
without supervision.

WARNING

To prevent electrical shocks or fire:

▪ Do NOT rinse the unit.

▪ Do NOT operate the unit with wet

hands.

▪ Do NOT place any objects containing

water on the unit.

CAUTION

▪ Do NOT place any objects or

equipment on top of the unit.

▪ Do NOT sit, climb or stand on the

unit.

▪ Units are marked with the following symbol:

This  means  that  electrical  and  electronic  products  may  NOT  be
mixed  with  unsorted  household  waste.  Do  NOT  try  to  dismantle
the  system  yourself:  the  dismantling  of  the  system,  treatment  of
the  refrigerant,  of  oil  and  of  other  parts  MUST  be  done  by  an
authorised installer and MUST comply with applicable legislation.

Units MUST be treated at a specialised treatment facility for reuse,
recycling  and  recovery.  By  ensuring  this  product  is  disposed  of
correctly, you will help to prevent potential negative consequences
for  the  environment  and  human  health.  For  more  information,
contact your installer or local authority.

▪ Batteries are marked with the following symbol:

This  means  that  the  batteries  may  NOT  be  mixed  with  unsorted
household  waste.  If  a  chemical  symbol  is  printed  beneath  the
symbol,  this  chemical  symbol  means  that  the  battery  contains  a
heavy metal above a certain concentration.

Possible chemical symbols are: Pb: lead (>0.004%).

Waste  batteries  MUST  be  treated  at  a  specialised  treatment
facility  for  reuse.  By  ensuring  waste  batteries  are  disposed  of
correctly, you will help to prevent potential negative consequences
for the environment and human health.

2.2

Instructions for safe operation

WARNING: MILDLY FLAMMABLE
MATERIAL

The refrigerant inside this unit is mildly
flammable.

WARNING

The appliance shall be stored so as to
prevent mechanical damage and in a
well-ventilated room without
continuously operating ignition sources
(example: open flames, an operating
gas appliance or an operating electric
heater).

WARNING

▪ Do NOT pierce or burn refrigerant

cycle parts.

▪ Do NOT use cleaning materials or

means to accelerate the defrosting
process other than those
recommended by the manufacturer.

▪ Be aware that the refrigerant inside

the system is odourless.

Summary of Contents for Altherma EAVZ16S18DA6V

Page 1: ...Operation manual Daikin Altherma 3 H F English Operation manual Daikin Altherma 3 H F EAVZ16S18DA6V 7 EAVZ16S23DA6V 7 EAVZ16S18DA9W EAVZ16S23DA9W...

Page 2: ...filled in the installer settings tables If NOT request him to do so Keep the documentation for future reference Target audience End users Documentation set This document is part of a documentation se...

Page 3: ...oil and of other parts MUST be done by an authorised installer and MUST comply with applicable legislation Units MUST be treated at a specialised treatment facility for reuse recycling and recovery B...

Page 4: ...ng cooling heat pump model is installed Produce domestic hot water INFORMATION Cooling is only applicable in case a conversion kit EKHVCONV is installed 3 1 Components in a typical system layout d a b...

Page 5: ...side of the screen Turn the right dial Navigate through the possible values and settings Press the right dial Confirm your choice and go to the next menu item 4 2 Possible screens Overview The most c...

Page 6: ...t Enter the submenu Enable disable breadcrumbs Submenu Description 0 or Malfunctioning Restriction Only displayed if a malfunction occurs See 7 1 To display the help text in case of a malfunction 415...

Page 7: ...alue Go to the next setting Confirm changes and proceed 4 3 Turning operation ON or OFF 4 3 1 Visual indication Certain functionalities of the unit can be enabled or disabled separately If a functiona...

Page 8: ...l it can both heat up and cool down a space You have to tell the system which operation mode to use To tell the system which space operation to use you can You can Location Check which space operation...

Page 9: ...water corresponding to a schedule The best time to allow the tank to produce hot water is at night because the space heating demand is lower Example t 60 C 00 00 07 00 50 C 15 C 40 C 14 00 21 00 1 2...

Page 10: ...st of digits and change the selected digit Move the cursor from left to right Confirm the pin code and proceed User pin code The User pin code is 0000 0000 User Advanced user pin code The Advanced use...

Page 11: ...programmed action In this example Monday is the first day you programmed Thus the last programmed action is valid up to the first action of next Monday To copy the schedule to the other weekdays 1 Se...

Page 12: ...e Rename Select 3 optional To delete the current schedule name browse through the character list until is displayed then press to remove the previous character Repeat for each character of the schedul...

Page 13: ...edule 7 User settings Language Time date Holiday Quiet Electricity price Gas price 8 Information Energy data Malfunction history Dealer information Sensors Actuators Operation modes About Connection s...

Page 14: ...hours For longer periods You can use the holiday mode Tips about DHW tank temperature Use a weekly schedule for your normal domestic hot water needs ONLY in scheduled mode Program to heat up the DHW t...

Page 15: ...ture See 4 4 2 To change the desired room temperature 48 If the problem recurs daily do one of the following Increase decrease the room temperature preset value See the user reference guide Adjust the...

Page 16: ...text in case of a malfunction 415 for more information about the malfunction a We recommend to purge air with the air purge function of the unit to be performed by the installer If you purge air from...