![background image](http://html.mh-extra.com/html/daikin/altherma-chyhbh05af/altherma-chyhbh05af_installers-reference-manual_501230206.webp)
15
|
Technical data
Installer reference guide
206
C08AF + EHYKOMB33A
Daikin Altherma R Hybrid
4P471761-1E – 2020.10
EHYKOMB33AA*
Efficiency space heating (net calorific value
80/60) η
100
98.7%
Efficiency space heating (net calorific value
37/30 - 30%) η
30
108.3%
Operation range
30~90°C
Pressure drop
See
204].
Domestic hot water (not applicable for Switzerland)
Nominal load domestic hot water Q
nw
(H
s
)
8.4~36.3 kW
Nominal load domestic hot water Q
nw
(H
i
)
7.6~32.7 kW
Maximum water pressure PMW
8 bar
Efficiency domestic hot water (net calorific
value)
105%
Operation range
40~65°C
Domestic hot water flow rate (setpoint 60°C)
9 l/min
Domestic hot water flow rate (setpoint 40°C)
15 l/min
Domestic water threshold
2 l/min.
Effective unit wait time
<1 sec
Domestic water side pressure difference
See
Casing
Colour
White – RAL9010
Material
Pre-coated sheet metal
Dimensions
Packing (H×W×D)
900×500×300 mm
Unit (H×W×D)
710×450×240 mm
Machine net weight
36 kg
Packed machine weight
37 kg
Packing material
Carton/PP (straps)
Packing material (weight)
1 kg
Boiler water volume
4 l
Main components
Water side heat exchanger
Aluminium, copper
Space heating water circuit
Space heating piping connections
Ø22 mm
Piping material
Cu
Safety valve
See indoor unit manual
Manometer
Digital